A New Algorithm for Spectral Drift Calculation in a Gamma-ray Spectrometer

被引:2
|
作者
Qin Zhangjian [1 ]
Ge Liangquan [1 ]
Wu Qifan [2 ]
Cheng Jianping [2 ]
机构
[1] Chengdu Univ Technol, Sch Nucl Technol & Automat Engn, Chengdu 610059, Peoples R China
[2] Tsinghua Univ, Dept Phys Elect, Beijing 100084, Peoples R China
来源
SUSTAINABLE CONSTRUCTION MATERIALS AND COMPUTER ENGINEERING | 2012年 / 346卷
关键词
Spectral drift; Spectra stabilization; Gamma-ray spectrometer; Least squares method; STABILIZATION; DETECTORS;
D O I
10.4028/www.scientific.net/AMR.346.705
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Spectral drift of any origin consisting of detectors and nuclear electronics affects the long-term stability in a gamma-ray spectrometer, which is essential to maintaining the high quality of gamma energy spectra. The feedback regulation according to the quantity of spectral drift can restore the system's stability. A new algorithm for spectral drift calculation is given in this paper. A digital logic unit is developed in a FPGA chip based on the algorithm, and a MCU coordinating with it can fast calculate the spectral drift within only less than 110 instruction periods.
引用
收藏
页码:705 / +
页数:2
相关论文
共 50 条
  • [21] CALIBRATION OF A PORTABLE GAMMA-RAY SPECTROMETER
    GIBSON, JAB
    BURT, AK
    HEALTH PHYSICS, 1968, 15 (04): : 333 - +
  • [22] An Imaging Neutron/Gamma-Ray Spectrometer
    Ryan, James M.
    Bancroft, Christopher
    Bloser, Peter
    Fourguette, Dominique
    Larocque, Liane
    Legere, Jason
    Madden, Amanda
    McConnell, Mark L.
    Pavlich, Jane
    Ritter, Greg
    Wassick, Greg
    Rousseau, Marissa
    PENETRATING RADIATION SYSTEMS AND APPLICATIONS XIII, 2012, 8509
  • [23] A PORTABLE GAMMA-RAY SPECTROMETER COMPUTER
    ROBERTS, H
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1984, 31 (01) : 676 - 678
  • [24] MERCURIC IODIDE GAMMA-RAY SPECTROMETER
    MALM, HL
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1972, NS19 (03) : 263 - &
  • [25] FREGATE, A GAMMA-RAY SPECTROMETER FOR HETE
    ATTEIA, JL
    NIEL, M
    CASSIGNOL, M
    COTIN, F
    COUTERET, J
    EHANNO, M
    EVRARD, J
    LAGRANGE, D
    LAMY, A
    MAINGUENE, J
    OLIVE, JF
    ROUAIX, G
    SOULEILLE, P
    VEDRENNE, G
    ASTROPHYSICS AND SPACE SCIENCE, 1995, 231 (1-2) : 471 - 474
  • [26] Mobile collimated gamma-ray spectrometer
    National Scientific Center, Kharkiv Physical and Technological Institute, 1, Academicheskaya St., Kharkiv
    61108, Ukraine
    Telecommun Radio Eng, 1 (87-93):
  • [27] Calibration of the NEAR gamma-ray spectrometer
    Evans, LG
    Starr, R
    Trombka, JI
    McClanahan, TP
    Bailey, SH
    Mikheeva, I
    Bhangoo, J
    Brückner, J
    Goldsten, JO
    ICARUS, 2000, 148 (01) : 95 - 117
  • [28] STABILIZATION SYSTEMS OF A GAMMA-RAY SPECTROMETER
    SABO, L
    SOTNIKOV, SK
    DANELYAN, LS
    KARDON, B
    SHERESH, Z
    LOKHONYA.L
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1970, (03): : 708 - &
  • [29] ELECTRON TRAJECTORIES IN A GAMMA-RAY SPECTROMETER
    HURWITZ, H
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1949, 20 (04): : 318 - 318
  • [30] AN AUTOMATIC RECORDING GAMMA-RAY SPECTROMETER
    STRICKLER, TD
    WADEY, WG