Characterization of photodamage in coherent anti-Stokes Raman scattering microscopy

被引:163
作者
Fu, Y [1 ]
Wang, HF
Shi, RY
Cheng, JX
机构
[1] Purdue Univ, Weldon Sch Biomed Engn, W Lafayette, IN 47907 USA
[2] Purdue Univ, Dept Chem, W Lafayette, IN 47907 USA
[3] Purdue Univ, Dept Basic Med Sci, Inst Appl Neurol, W Lafayette, IN 47907 USA
[4] Purdue Univ, Ctr Paralysis Res, W Lafayette, IN 47907 USA
来源
OPTICS EXPRESS | 2006年 / 14卷 / 09期
关键词
D O I
10.1364/OE.14.003942
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We report a mechanistic analysis of photodamage in coherent anti-Stokes Raman scattering (CARS) microscopy. Photodamage to the myelin sheath in spinal tissues is induced by using the point scan mode and is featured by myelin splitting and shockwaves with broadband emission. Our measurement of photodamage rate versus the excitation power reveals that both linear and nonlinear mechanisms are involved. Moreover, we show that vibrational absorption induced by coherent Raman processes significantly contributes to the nonlinear damage at high peak powers. For CARS imaging of cultured cells, the photodamage is characterized by plasma membrane blebbing and is dominated by a second order mechanism. Our study suggests that for dense samples such as the myelin sheath, CARS imaging induced photodamage can be minimized by using laser beams with relatively long near IR wavelengths and a repetition rate of a few MHz. For less dense samples such as cultured cells, laser pulses of higher repetition rates are preferred. (c) 2006 Optical Society of America.
引用
收藏
页码:3942 / 3951
页数:10
相关论文
共 43 条
[1]   Nuclear energy in the twenty-first century: Examination of a contentious subject [J].
Beck, PW .
ANNUAL REVIEW OF ENERGY AND THE ENVIRONMENT, 1999, 24 :113-137
[2]   Molecularly sensitive optical coherence tomography [J].
Bredfeldt, JS ;
Vinegoni, C ;
Marks, DL ;
Boppart, SA .
OPTICS LETTERS, 2005, 30 (05) :495-497
[3]   Second-harmonic imaging microscopy for visualizing biomolecular arrays in cells, tissues and organisms [J].
Campagnola, PJ ;
Loew, LM .
NATURE BIOTECHNOLOGY, 2003, 21 (11) :1356-1360
[4]   Coherent anti-Stokes Raman scattering microscopy: Instrumentation, theory, and applications [J].
Cheng, JX ;
Xie, XS .
JOURNAL OF PHYSICAL CHEMISTRY B, 2004, 108 (03) :827-840
[5]   Ordering of water molecules between phospholipid bilayers visualized by coherent anti-Stokes Raman scattering microscopy [J].
Cheng, JX ;
Pautot, S ;
Weitz, DA ;
Xie, XS .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2003, 100 (17) :9826-9830
[6]   Theoretical and experimental characterization of coherent anti-Stokes Raman scattering microscopy [J].
Cheng, JX ;
Volkmer, A ;
Xie, XS .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 2002, 19 (06) :1363-1375
[7]   An epi-detected coherent anti-stokes raman scattering (E-CARS) microscope with high spectral resolution and high sensitivity [J].
Cheng, JX ;
Volkmer, A ;
Book, LD ;
Xie, XS .
JOURNAL OF PHYSICAL CHEMISTRY B, 2001, 105 (07) :1277-1280
[8]   PHOTOSENSITIZED PRODUCTION OF SUPEROXIDE ANION BY MONOCHROMATIC (290-405 NM) ULTRAVIOLET-IRRADIATION OF NADH AND NADPH COENZYMES [J].
CUNNINGHAM, ML ;
JOHNSON, JS ;
GIOVANAZZI, SM ;
PEAK, MJ .
PHOTOCHEMISTRY AND PHOTOBIOLOGY, 1985, 42 (02) :125-128
[9]   2-PHOTON LASER SCANNING FLUORESCENCE MICROSCOPY [J].
DENK, W ;
STRICKLER, JH ;
WEBB, WW .
SCIENCE, 1990, 248 (4951) :73-76
[10]  
DIELS J, 1996, ULTRASHORT LASER PHA, P472