Flexible sigmoidoscopy versus faecal occult blood testing for colorectal cancer screening in asymptomatic individuals

被引:173
作者
Holme, Oyvind [1 ]
Bretthauer, Michael [2 ]
Fretheim, Atle [3 ]
Odgaard-Jensen, Jan [4 ]
Hoff, Geir [5 ]
机构
[1] Sorlandet Hosp Kristiansand, Dept Med, N-4604 Kristiansand, Norway
[2] Univ Oslo, Dep Hlth Management & Hlth Econ, Inst Hlth & Soc, Oslo, Norway
[3] Norwegian Knowledge Ctr Hlth Serv, Global Hlth Unit, Oslo, Norway
[4] Norwegian Knowledge Ctr Hlth Serv, Oslo, Norway
[5] Telemark Hosp, Skien, Norway
来源
COCHRANE DATABASE OF SYSTEMATIC REVIEWS | 2013年 / 09期
关键词
RANDOMIZED CONTROLLED-TRIAL; ONCE-ONLY SIGMOIDOSCOPY; BASE-LINE FINDINGS; TELEMARK POLYP; FOLLOW-UP; PATIENT SATISFACTION; MORTALITY; COLONOSCOPY; POPULATION; NEOPLASIA;
D O I
10.1002/14651858.CD009259.pub2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Colorectal cancer is the third most frequent cancer in the world. As the sojourn time for this cancer is several years and a good prognosis is associated with early stage diagnosis, screening has been implemented in a number of countries. Both screening with faecal occult blood test and flexible sigmoidoscopy have been shown to reduce mortality from colorectal cancer in randomised controlled trials. The comparative effectiveness of these tests on colorectal cancer mortality has, however, never been evaluated, and controversies exist over which test to choose. Objectives To compare the effectiveness of screening for colorectal cancer with flexible sigmoidoscopy to faecal occult blood testing. Search methods We searched MEDLINE and EMBASE (November 16, 2012), the Cochrane Central Register of Controlled Trials (CENTRAL) (2012, Issue 11) and reference lists for eligible studies. Selection criteria Randomised controlled trials comparing screening with flexible sigmoidoscopy or faecal occult blood testing to each other or to no screening. Only studies reporting mortality from colorectal cancer were included. Faecal occult blood testing had to be repeated (annually or biennially). Data collection and analysis Data retrieval and assessment of risk of bias were performed independently by two review authors. Standard meta-analyses using a random-effects model were conducted for flexible sigmoidoscopy and faecal occult blood testing (FOBT) separately and we calculated relative risks with 95% confidence intervals (CI). We used a Bayesian approach (a contrast-based network meta-analysis method) for indirect analyses and presented the results as posterior median relative risk with 95% credibility intervals. We assessed the quality of evidence using GRADE. Main results We identified nine studies comprising 338,467 individuals randomised to screening and 405,919 individuals to the control groups. Five studies compared flexible sigmoidoscopy to no screening and four studies compared repetitive guaiac-based FOBT (annually and biennially) to no screening. We did not consider that study risk of bias reduced our confidence in our results. We did not identify any studies comparing the two screening methods directly. When compared with no screening, colorectal cancer mortality was lower with flexible sigmoidoscopy (relative risk 0.72; 95% CI 0.65 to 0.79, high quality evidence) and FOBT (relative risk 0.86; 95% CI 0.80 to 0.92, high quality evidence). In the analyses based on indirect comparison of the two screening methods, the relative risk of dying from colorectal cancer was 0.85 (95% credibility interval 0.72 to 1.01, low quality evidence) for flexible sigmoidoscopy screening compared to FOBT. No complications occurred after the FOBT test itself, but 0.03% of participants suffered a major complication after follow-up. Among more than 60,000 flexible sigmoidoscopy screening procedures and almost 6000 work-up colonoscopies, a major complication was recorded in 0.08% of participants. Adverse event data should be interpreted with caution as the reporting of adverse effects was incomplete. Authors' conclusions There is high quality evidence that both flexible sigmoidoscopy and faecal occult blood testing reduce colorectal cancer mortality when applied as screening tools. There is low quality indirect evidence that screening with either approach reduces colorectal cancer deaths more than the other. Major complications associated with screening require validation from studies with more complete reporting of harms.
引用
收藏
页数:66
相关论文
共 72 条
[1]   Predictors of proximal neoplasia in patients without distal adenomatous pathology [J].
Anderson, JC ;
Alpern, Z ;
Messina, CR ;
Lane, B ;
Hubbard, P ;
Grimson, R ;
Ells, PF ;
Brand, DL .
AMERICAN JOURNAL OF GASTROENTEROLOGY, 2004, 99 (03) :472-477
[2]  
[Anonymous], 1975, SEER CANC STAT REV
[3]  
[Anonymous], 2008, COCHRANE HDB SYSTEMA
[4]   Once-only flexible sigmoidoscopy screening in prevention of colorectal cancer: a multicentre randomised controlled trial [J].
Atkin, Wendy S. ;
Edwards, Rob ;
Kralj-Hans, Ines ;
Wooldrage, Kate ;
Hart, Andrew R. ;
Northover, John M. A. ;
Parkin, D. Max ;
Wardle, Jane ;
Duffy, Stephen W. ;
Cuzick, Jack .
LANCET, 2010, 375 (9726) :1624-1633
[5]   Single flexible sigmoidoscopy screening to prevent colorectal cancer: baseline findings of a UK multicentre randomised trial [J].
Atkin, WS ;
Cook, CF ;
Cuzick, J ;
Edwards, R ;
Northover, JMA ;
Wardle, J .
LANCET, 2002, 359 (9314) :1291-1300
[6]   LONG-TERM RISK OF COLORECTAL-CANCER AFTER EXCISION OF RECTOSIGMOID ADENOMAS [J].
ATKIN, WS ;
MORSON, BC ;
CUZICK, J .
NEW ENGLAND JOURNAL OF MEDICINE, 1992, 326 (10) :658-662
[7]   Association of Colonoscopy and Death From Colorectal Cancer [J].
Baxter, Nancy N. ;
Goldwasser, Meredith A. ;
Paszat, Lawrence F. ;
Saskin, Refik ;
Urbach, David R. ;
Rabeneck, Linda .
ANNALS OF INTERNAL MEDICINE, 2009, 150 (01) :1-W1
[8]  
Berry DP, 1997, BRIT J SURG, V84, P1274
[9]  
Bland JM, 1997, BRIT MED J, V315, P600
[10]   Protection From Colorectal Cancer After Colonoscopy A Population-Based, Case-Control Study [J].
Brenner, Hermann ;
Chang-Claude, Jenny ;
Seiler, Christoph M. ;
Rickert, Alexander ;
Hoffmeister, Michael .
ANNALS OF INTERNAL MEDICINE, 2011, 154 (01) :22-U156