Detection of Cytomegalovirus in Whole Blood Using Three Different Real-Time PCR Chemistries

被引:10
作者
Vincent, Erica [1 ]
Gu, Zhengming [1 ]
Morgenstern, Markus [1 ]
Gibson, Candace [1 ]
Pan, Jianmin [2 ]
Hayden, Randall T. [1 ]
机构
[1] St Jude Childrens Hosp, Dept Pathol, Memphis, TN 38103 USA
[2] St Jude Childrens Hosp, Dept Biostat, Memphis, TN 38103 USA
关键词
EPSTEIN-BARR-VIRUS; ORGAN TRANSPLANT PATIENTS; AMPLICOR CMV MONITOR; PERIPHERAL-BLOOD; QUANTITATIVE DETECTION; PP65; ANTIGENEMIA; AUTOMATED PCR; VIRAL LOAD; DNA; QUANTIFICATION;
D O I
10.2353/jmoldx.2009.080073
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
Several different primer-probe chemistries have been produced commercially for real-time PCR detection and quantification of cytomegalovirus, but there are few studies evaluating their relative performance. We assessed three such commercial reagents with respect to analytical and clinical operating characteristics. The samples included 149 clinical whole blood specimens that were de-identified and assayed in parallel with all primer-probe systems. Individual methods used TaqMan, dual fluorescence resonance energy transfer hybridization probes, and labeled primer chemistries. Method comparability was determined both qualitatively, based on pair-wise assessment of concordance, and quantitatively, based on pair-wise linear regression analysis. Analytical sensitivity and the lower end of the linear dynamic range reached 10 target copies per reaction for the TaqMan and labeled primer systems and 100 target copies per reaction for the dual fluorescence resonance energy transfer probe system. Quantitative linearity reached an upper limit of 105 copies per reaction for all methods. No assay cross-reactivity was seen with other common viral pathogens (100% analytical specificity). Pair-wise analysis of qualitative results from clinical samples showed no significant differences in sensitivity between the three sets of reagents, and linear regression analysis indicated that the quantitative values achieved were comparable in all positive specimens. The findings demonstrate that similar analytical and clinical performance characteristics can be demonstrated for quantitative detection of cytomegalovirus in clinical whole blood extracts using a wide variety of real-time PCR chemistries. (J mol Diagn 2009, 11:54-59; DOI: 10.2353/jmoldx.2009.080073)
引用
收藏
页码:54 / 59
页数:6
相关论文
共 32 条
  • [1] AGRESTI A, 2002, CATEGORICAL DATA ANA, P348
  • [2] Monitoring human cytomegalovirus infection in transplant recipients
    Baldanti, Fausto
    Lilleri, Daniele
    Gerna, Giuseppe
    [J]. JOURNAL OF CLINICAL VIROLOGY, 2008, 41 (03) : 237 - 241
  • [3] A rapid real-time quantitative polymerase chain reaction for hepatitis B virus
    Brechtbuehl, K
    Whalley, SA
    Dusheiko, GM
    Saunders, NA
    [J]. JOURNAL OF VIROLOGICAL METHODS, 2001, 93 (1-2) : 105 - 113
  • [4] Evaluation of real-time PCR laboratory-developed tests using analyte-specific reagents for cytomegalovirus quantification
    Caliendo, Angela M.
    Ingersoll, Jessica
    Fox-Canale, Andrea M.
    Pargman, Sabine
    Bythwood, Tameka
    Hayden, Mary K.
    Bremer, James W.
    Lurain, Nell S.
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2007, 45 (06) : 1723 - 1727
  • [5] Fluorescence energy transfer detection as a homogeneous DNA diagnostic method
    Chen, XN
    Zehnbauer, B
    Gnirke, A
    Kwok, PY
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1997, 94 (20) : 10756 - 10761
  • [6] Quantification of human cytomegalovirus DNA by real-time PCR
    Gault, E
    Michel, Y
    Dehée, A
    Belabani, C
    Nicolas, JC
    Garbarg-Chenon, A
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2001, 39 (02) : 772 - 775
  • [7] Quantification of human cytomegalovirus DNA in bone marrow transplant recipients by real-time PCR
    Griscelli, F
    Barrois, M
    Chauvin, S
    Lastere, S
    Bellet, D
    Bourhis, JH
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2001, 39 (12) : 4362 - 4369
  • [8] Multiplexed, real-time PCR for quantitative detection of human adenovirus
    Gu, Z
    Belzer, SW
    Gibson, CS
    Bankowski, MJ
    Hayden, RT
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (10) : 4636 - 4641
  • [9] Comparison of various blood compartments and reporting units for the detection and quantification of Epstein-Barr virus in peripheral blood
    Hakim, H.
    Gibson, C.
    Pan, J.
    Srivastava, K.
    Gu, Z.
    Bankowski, M. J.
    Hayden, R. T.
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2007, 45 (07) : 2151 - 2155
  • [10] Hayden RT, 2008, J CLIN MICROBIOL, V46, P157, DOI 10.1128/JCM.01252-07