Self-expandable transcatheter aortic valve implantation for aortic stenosis after mitral valve surgery

被引:23
作者
Bruschi, Giuseppe [1 ]
De Marco, Federico [1 ]
Barosi, Alberto [1 ]
Colombo, Paola [1 ]
Botta, Luca [1 ]
Nonini, Sandra [2 ]
Martinelli, Luigi [1 ]
Klugmann, Silvio [1 ]
机构
[1] Osped Niguarda Ca Granda, A De Gasperis Cardiol & Cardiac Surg Dept, I-20162 Milan, Italy
[2] Osped Niguarda Ca Granda, Milan, Italy
关键词
Aortic valve; Replacement; Heart valve; Transapical; Percutaneous; Mechanical; HIGH-RISK PATIENTS; PERCUTANEOUS IMPLANTATION; REPLACEMENT; PROSTHESIS; POSITION;
D O I
10.1093/icvts/ivt086
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Transcatheter aortic valve implantation has emerged as a valuable option to treat patients with symptomatic severe aortic stenosis, who are not being considered for surgery because of significant comorbidities. Concerns exist over treating patients who have previously undergone mitral valve surgery for possible interference between the percutaneous aortic valve and the mitral prosthesis or ring. At our centre, from May 2008 to December 2012, 172 patients (76 male) with severe symptomatic aortic stenosis were eligible for transcatheter aortic valve implant. Nine patients, affected by severe aortic stenosis, had previously undergone mitral valve surgery (4 mono-leaflet, 3 bileaflet, 1 bioprosthesis, 1 mitral ring); they were considered high-risk surgical candidates following joint evaluation by cardiac surgeons and cardiologist and had undergone TAVI. Seven patients underwent standard femoral retrograde CoreValve((R)) (Medtronic Inc., Minneapolis, USA) implantation, two patients underwent a direct aortic implantation through a mini-thoracotomy. All patients experienced immediate improvement of their haemodynamic status. No deformation of the nitinol tubing of the CoreValve, nor distortion or malfunction of the mechanical valve or mitral ring, occurred as assessed by echographical and fluoroscopic evaluation. No major postoperative complications occurred. In all patients , echocardiography indicated normal valve function during follow-up. Our experience confirms the feasibility of CoreValve implantation in patients with mechanical mitral valves or mitral annuloplasty ring.
引用
收藏
页码:90 / 95
页数:6
相关论文
共 15 条
[1]   Risk of reoperative valve replacement for failed mitral and aortic bioprostheses - Discussion [J].
Geha, AS ;
Akins, CW ;
Scully, HE ;
Ferdinand, FD ;
Schaff, HV ;
Oswalt, JD ;
Jamieson, WRE .
ANNALS OF THORACIC SURGERY, 1998, 65 (06) :1551-1552
[2]   Direct Aortic Access for Transcatheter Self-Expanding Aortic Bioprosthetic Valves Implantation [J].
Bruschi, Giuseppe ;
de Marco, Federico ;
Botta, Luca ;
Cannata, Aldo ;
Oreglia, Jacopo ;
Colombo, Paola ;
Barosi, Alberto ;
Colombo, Tiziano ;
Nonini, Sandra ;
Paino, Roberto ;
Klugmann, Silvio ;
Martinelli, Luigi .
ANNALS OF THORACIC SURGERY, 2012, 94 (02) :497-503
[3]   Percutaneous Implantation of CoreValve Aortic Prostheses in Patients With a Mechanical Mitral Valve [J].
Bruschi, Giuseppe ;
De Marco, Federico ;
Oreglia, Jacopo ;
Colombo, Paola ;
Fratto, Pasquale ;
Lullo, Francesca ;
Paino, Roberto ;
Frigerio, Maria ;
Martinelli, Luigi ;
Klugmann, Silvio .
ANNALS OF THORACIC SURGERY, 2009, 88 (05) :E50-E52
[4]   Treatment of calcific aortic stenosis with the percutaneous heart valve - Mid-term follow-up from the initial feasibility studies: The French experience [J].
Cribier, A ;
Eltchaninoff, H ;
Tron, C ;
Bauer, F ;
Agatiello, C ;
Nercolini, D ;
Tapiero, S ;
Litzler, PY ;
Bessou, JP ;
Babaliaros, V .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (06) :1214-1223
[5]   Transapical aortic valve implantation after previous mitral valve surgery [J].
Drews, Thorsten ;
Pasic, Miralem ;
Buz, Semih ;
Unbehaun, Axel ;
Dreysse, Stephan ;
Kukucka, Marian ;
Mladenow, Alexander ;
Hetzer, Roland .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2011, 142 (01) :84-88
[6]  
García E, 2011, REV ESP CARDIOL, V64, P1052, DOI [10.1016/j.recesp.2011.02.022, 10.1016/j.rec.2011.02.025]
[7]   Percutaneous implantation of the CoreValve self-expanding valve prosthesis in high-risk patients with aortic valve disease - The Siegburg First-in-Man Study [J].
Grube, Eberhard ;
Laborde, Jean C. ;
Gerckens, Ulrich ;
Felderhoff, Thomas ;
Sauren, Barthel ;
Buellesfeld, Lutz ;
Mueller, Ralf ;
Menichelli, Maurizio ;
Schmidt, Thomas ;
Zickmann, Bernfried ;
Iversen, Stein ;
Stone, Gregg W. .
CIRCULATION, 2006, 114 (15) :1616-1624
[8]   Progress and Current Status of Percutaneous Aortic Valve Replacement: Results of Three Device Generations of the CoreValve Revalving System [J].
Grube, Eberhard ;
Buellesfeld, Lutz ;
Mueller, Ralf ;
Sauren, Barthel ;
Zickmann, Bernfried ;
Nair, Dinesh ;
Beucher, Harald ;
Felderhoff, Thomas ;
Iversen, Stein ;
Gerckens, Ulrich .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2008, 1 (03) :167-175
[9]   Re-operation for bioprosthetic aortic structural failure - risk assessment [J].
Jamieson, WRE ;
Burr, LH ;
Miyagishima, RT ;
Janusz, MT ;
Fradet, GJ ;
Ling, H ;
Lichtenstein, S .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2003, 24 (06) :873-878
[10]   Two-Year Outcomes after Transcatheter or Surgical Aortic-Valve Replacement [J].
Kodali, Susheel K. ;
Williams, Mathew R. ;
Smith, Craig R. ;
Svensson, Lars G. ;
Webb, John G. ;
Makkar, Raj R. ;
Fontana, Gregory P. ;
Dewey, Todd M. ;
Thourani, Vinod H. ;
Pichard, Augusto D. ;
Fischbein, Michael ;
Szeto, Wilson Y. ;
Lim, Scott ;
Greason, Kevin L. ;
Teirstein, Paul S. ;
Malaisrie, S. Chris ;
Douglas, Pamela S. ;
Hahn, Rebecca T. ;
Whisenant, Brian ;
Zajarias, Alan ;
Wang, Duolao ;
Akin, Jodi J. ;
Anderson, William N. ;
Leon, Martin B. .
NEW ENGLAND JOURNAL OF MEDICINE, 2012, 366 (18) :1686-1695