Assessment of a novel hysteretic friction damper for the seismic retrofit of reinforced concrete frame structures

被引:19
作者
Bruschi, Eleonora [1 ]
Quaglini, Virginio [1 ]
机构
[1] Politecn Milan, Dept Architecture, Built Environm & Construct Engn, Piazza Leonardo Vinci 32, I-20133 Milan, Italy
关键词
Friction hysteretic damper; Lead damper; Energy dissipation; Reinforced concrete; Seismic rehabilitation; Non-linear analyses; OpenSees; DESIGN; BRACES;
D O I
10.1016/j.istruc.2022.10.113
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this paper, a novel hysteretic friction damper, called Prestressed LEad Damper with Straight Shaft (or PS-LED), is presented as a viable solution for the seismic rehabilitation of existing RC framed buildings. The PS-LED is characterized by high stiffness and damping capability combined with a compact design, and low manufacturing cost, which make it suitable for social housing. The constitutive behavior of the PS-LED, assessed experimentally in cyclic tests at different speeds, is formulated in the OpenSees framework through a simple rheological model comprising a parallel of a non-linear spring and a viscous model. To explore the viability of the PS-LED for seismic upgrade of existing buildings, a numerical investigation is performed by considering a RC frame structure, paradigmatic of a category of Italian buildings designed ac-cording to outdated codes. The case-study structure retrofit is designed considering two possible damage targets: (i) in the first case, the upgrade is performed in order to achieve elastic response of the structure under the basic design earthquake; (ii) in the second case, a partially dissipative behavior of the RC frame is conceived, with activation of plastic hinges to a repairable level. Non-linear static and Non-linear dynamic analyses are per-formed, showing a satisfactory agreement between the seismic performance and the design targets. As final stage, a comparison between two retrofit solutions with either the PS-LED or with a conventional steel hysteretic damper (SHD) is performed, demonstrating that the PS-LED, thanks to its high damping capacity, is able to control the increase in internal forces that usually affects frames upgraded with SHDs.
引用
收藏
页码:793 / 811
页数:19
相关论文
共 57 条
[1]   Evaluation of Simplified and State-of-the-Art Analysis Procedures for Steel Frame Buildings Equipped with Supplemental Damping Devices Based on E-Defense Full-Scale Shake Table Tests [J].
Akcelyan, Sarven ;
Lignos, Dimitrios G. ;
Hikino, Tsuyoshi ;
Nakashima, Masayoshi .
JOURNAL OF STRUCTURAL ENGINEERING, 2016, 142 (06)
[2]  
[Anonymous], 2009, GEOTECHNICAL GEOLOGI, DOI DOI 10.1007/978-90-481-2681-1_13
[3]  
[Anonymous], SIMQKE SIMULATION EA
[4]  
[Anonymous], 1996, ATC-40, Seismic Evaluation and Retrofit of Concrete Buildings (November 1996), P1
[5]  
[Anonymous], OPENSEESWIKI ONLINE
[6]  
[Anonymous], 1996, CEB STAT ART REP
[7]   On the fibre modelling of beams in RC framed buildings with rigid diaphragm [J].
Barbagallo, Francesca ;
Bosco, Melina ;
Marino, Edoardo M. ;
Rossi, Pier Paolo .
BULLETIN OF EARTHQUAKE ENGINEERING, 2020, 18 (01) :189-210
[8]   A multi-performance design method for seismic upgrading of existing RC frames by BRBs [J].
Barbagallo, Francesca ;
Bosco, Melina ;
Marino, Edoardo M. ;
Rossi, Pier Paolo ;
Stramondo, Paola R. .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2017, 46 (07) :1099-1119
[9]   A design procedure of dissipative braces for seismic upgrading structures [J].
Bergami, A. V. ;
Nuti, C. .
EARTHQUAKES AND STRUCTURES, 2013, 4 (01) :85-108
[10]  
Bruschi E, 2021, THESIS POLITECNICO M