Inertia response from full-power converter-based permanent magnet wind generators

被引:34
作者
Licari, John [1 ]
Ekanayake, Janaka [1 ,2 ]
Moore, Ian [1 ]
机构
[1] Cardiff Univ, Inst Energy, Cardiff CF24 3AA, S Glam, Wales
[2] Univ Peradeniya, Peradeniya, Sri Lanka
关键词
Inertia response; Frequency response; Full-rated power converter; Wind turbines; FREQUENCY-RESPONSE; SUPPORT; CAPABILITY; TURBINES;
D O I
10.1007/s40565-013-0002-6
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
With a high penetration of wind turbines, the proportion of synchronous generation in the power system will be reduced at times, thus creating operating difficulties especially during frequency events. Therefore, it is anticipated that many grid operators will demand inertia response from wind turbines. In this article, different ways for emulating inertia response in full-rated power converter-based wind turbines equipped with permanent magnet synchronous generators are considered. Supplementary control signals are added to the controller of the wind turbine to extract stored energy from the rotating mass and DC-link capacitors. Simulations in MATLAB/Simulink show that the inertia response is improved by adding a term proportional to the rate of change of frequency and by extracting the stored energy in the DC-link capacitors.
引用
收藏
页码:26 / 33
页数:8
相关论文
共 18 条
[1]  
[Anonymous], 2009, Transmission provider technical requirements for the connection of power plants to the Hydro Quebec transmission system
[2]  
[Anonymous], THESIS U MANCHESTER
[3]  
Burton T., 2001, Wind Energy Handbook
[4]   Frequency response capability of full converter wind turbine generators in comparison to conventional generation [J].
Conroy, James F. ;
Watson, Rick .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2008, 23 (02) :649-656
[5]   Frequency Response From Wind Turbines [J].
Ekanayake, J. ;
Jenkins, N. ;
Strbac, G. .
WIND ENGINEERING, 2008, 32 (06) :573-586
[6]  
ENTSO-E, 2011, NETW COD REQ GRID CO
[7]   NGC experience with frequency control in England and Wales - Provision of frequency response by generators [J].
Erinmez, IA ;
Bickers, DO ;
Wood, GF ;
Hung, WW .
IEEE POWER ENGINEERING SOCIETY - 1999 WINTER MEETING, VOLS 1 AND 2, 1999, :590-596
[8]   Active Damping for PMSG-Based WECS With DC-Link Current Estimation [J].
Geng, Hua ;
Xu, Dewei ;
Wu, Bin ;
Yang, Geng .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2011, 58 (04) :1110-1119
[9]   Multi-pole permanent magnet synchronous generator wind turbines' grid support capability in uninterrupted operation during grid faults [J].
Hansen, A. D. ;
Michalke, G. .
IET RENEWABLE POWER GENERATION, 2009, 3 (03) :333-348
[10]   Dynamic Contribution of DFIG-Based Wind Plants to System Frequency Disturbances [J].
Kayikci, Mustafa ;
Milanovic, Jovica V. .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2009, 24 (02) :859-867