Heat transfer and pressure drop in the horizontal double pipes with and without twisted tape insert

被引:128
作者
Naphon, P [1 ]
机构
[1] Srinakharinwirot Univ, Dept Mech Engn, Fac Engn, Ongkarak 26120, Nakhon Nayok, Thailand
关键词
heat transfer; twisted tape insert; pressure drop;
D O I
10.1016/j.icheatmasstransfer.2005.09.007
中图分类号
O414.1 [热力学];
学科分类号
摘要
The heat transfer characteristics and the pressure drop in the horizontal double pipes with twisted tape insert are investigated. Two test sections with different relative pitches are tested. The inner and outer diameters of the inner tube are 8.10 and 9.54 mm, respectively. The twisted tape is made from the aluminium strip with thickness of 1 mm and the length of 2000 mm. Cold and hot water are used as working fluids in shell side and tube side, respectively. The test runs are done at the cold and hot water mass flow rates ranging between 0.01 and 0.07 kg/s, and between 0.04 and 0.08 kg/s, respectively. The inlet cold and hot water temperatures are between 15 and 20 degrees C, and between 40 and 45 degrees C, respectively. The results obtained from the tube with twisted insert are compared with those without twisted tape. Non-isothermal correlations based on the data gathered during this work for predicting the heat transfer coefficient and friction factor of the horizontal pipe with twisted taped insert are proposed. The majority of the data falls within +/- 15%, +/- 10% of the proposed correlations for heat transfer coefficient and friction factor, respectively. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:166 / 175
页数:10
相关论文
共 15 条
[1]   Heat transfer augmentation for the flow of a viscous liquid in circular tubes using twisted tape inserts [J].
Agarwal, SK ;
Rao, MR .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1996, 39 (17) :3547-3557
[2]   Pressure drop and heat transfer comparison for both microfin tube and twisted-tape inserts in laminar flow [J].
Al-Fahed, S ;
Chamra, LM ;
Chakroun, W .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 1998, 18 (04) :323-333
[3]   The effects of inclination angle on flooding in a helically fluted tube with a twisted insert [J].
Kang, YT ;
Stout, R ;
Christensen, RN .
INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 1997, 23 (06) :1111-1129
[4]   Investigation of twisted tape inserted solar water heaters - heat transfer, friction factor and thermal performance results [J].
Kumar, A ;
Prasad, BN .
RENEWABLE ENERGY, 2000, 19 (03) :379-398
[5]   Augmentation of convective heat transfer inside tubes with three-dimensional internal extended surfaces and twisted-tape inserts [J].
Liao, Q ;
Xin, MD .
CHEMICAL ENGINEERING JOURNAL, 2000, 78 (2-3) :95-105
[6]   Experimental investigation of various turbulator inserts in gas-heated channels [J].
Neshumayev, D ;
Ots, A ;
Laid, J ;
Tiikma, T .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2004, 28 (08) :877-886
[7]   Friction and heat transfer characteristics of flow through square duct with twisted tape insert [J].
Ray, S ;
Date, AW .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2003, 46 (05) :889-902
[8]   Laminar flow and heat transfer through square duct with twisted tape insert [J].
Ray, S ;
Date, AW .
INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2001, 22 (04) :460-472
[9]   A combined approach to predict friction coefficients and convective heat transfer characteristics in A tube with twisted tape inserts for a wide range of Re and Pr [J].
Sarma, PK ;
Kishore, PS ;
Rao, VD ;
Subrahmanyam, T .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2005, 44 (04) :393-398
[10]   Laminar convective heat transfer with twisted tape inserts in a tube [J].
Sarma, PK ;
Subramanyam, T ;
Kishore, PS ;
Rao, VD ;
Kakac, S .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2003, 42 (09) :821-828