Highly sensitive near-simultaneous assay of multiple "lean meat agent" residues in swine urine using a disposable electrochemiluminescent immunosensors array

被引:43
作者
Li, Zongyun [1 ]
Wang, Yonghong [2 ]
Kong, Weijun [1 ]
Li, Cuifang [1 ]
Wang, Zhenxing [1 ]
Fu, Zhifeng [1 ]
机构
[1] Southwest Univ, Coll Pharmaceut Sci, Minist Educ, Key Lab Luminescence & Real Time Anal, Chongqing 400716, Peoples R China
[2] Ctr Anim Dis Control & Prevent Chonqing, Chongqing 401147, Peoples R China
关键词
beta(2)-agonist; Lean meat agent; Electrochemiluminescence; Multianalyte immunoassay; Immunosensors array; Screen-printed carbon electrode; ELECTROCHEMICAL IMMUNOSENSOR; IMMUNOASSAY; CLENBUTEROL; RACTOPAMINE; CHROMATOGRAPHY; SALBUTAMOL; PROTEINS; AGONISTS; PORK;
D O I
10.1016/j.bios.2012.07.007
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Nowadays, beta(2)-agonists are abused illegally as "lean meat agents" for food-producing animals, and cause increasing food-safety accidents in some countries. Due to their hazard to the human health, "lean meat agents" are banned in most countries and required to be routinely monitored. We herein report a disposable electrochemiluminescent immunosensors array for near-simultaneous assay of multiple beta(2)-agonise residues in swine urine, by using ractopamine and salbutamol as the models. In this investigation, a screen-printed carbon electrodes array was assembled and acted as the substrate of the immunosensors array. Then the immunosensors array was constructed by site-selectively immobilizing the antigens of ractopamine and salbutamol on the working electrodes of array. After the competitive immuno-binding, with the aid of a homemade single-pore-four-throw switch, the electrochemiluminescent signals of the two beta(2)-agonists were sequentially detected using a non-array detector. The limits of detection for ractopamine and salbutamol were 8.5 and 17 pg/mL, respectively, which were much lower than those of the most previous reports. Compared with other routine methods based on chromatography and ELISA, this method is more suitable for screening of multiple beta(2)-agonists in quantities of samples, owing to its merits of low cost, user-friendliness and high throughput, and shows great promise in food safety and agonise surveillance. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:311 / 314
页数:4
相关论文
共 34 条
[31]   Development of an analytical method for the determination of β2-agonist residues in animal tissues by high-performance liquid chromatography with on-line electrogenerated [Cu(HIO6)2]5--luminol chemiluminescence detection [J].
Zhang, Yantu ;
Zhang, Zhujun ;
Sun, Yonghua ;
Wei, Yue .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2007, 55 (13) :4949-4956
[32]   Highly sensitive detection of clenbuterol using competitive surface-enhanced Raman scattering immunoassay [J].
Zhu, Guichi ;
Hu, Yongjun ;
Gao, Jiao ;
Zhong, Liang .
ANALYTICA CHIMICA ACTA, 2011, 697 (1-2) :61-66
[33]   Rapid determination of hazardous compounds in food based on a competitive fluorescence microsphere immunoassay [J].
Zou, Mingqlang ;
Gao, Haixia ;
Li, Jinfeng ;
Xu, Fang ;
Wang, Ling ;
Jiang, Jizhi .
ANALYTICAL BIOCHEMISTRY, 2008, 374 (02) :318-324
[34]   Determination of β-adrenergic agonists by hapten microarray [J].
Zuo, Peng ;
Zhang, Yin ;
Liu, Jie ;
Ye, Bang-Ce .
TALANTA, 2010, 82 (01) :61-66