Generation of a Four-Class Attenuation Map for MRI-Based Attenuation Correction of PET Data in the Head Area Using a Novel Combination of STE/Dixon-MRI and FCM Clustering

被引:21
|
作者
Khateri, Parisa [1 ]
Rad, Hamidreza Saligheh [1 ,2 ]
Jafari, Amir Homayoun [2 ,3 ,4 ]
Kazerooni, Anahita Fathi [1 ,2 ]
Akbarzadeh, Afshin [1 ]
Moghadam, Mohsen Shojae [3 ,4 ]
Aryan, Arvin [5 ]
Ghafarian, Pardis [6 ,7 ]
Ay, Mohammad Reza [1 ,2 ]
机构
[1] Univ Tehran Med Sci, Res Ctr Mol & Cellular Imaging, Tehran, Iran
[2] Univ Tehran Med Sci, Dept Med Phys & Biomed Engn, Tehran, Iran
[3] Univ Tehran Med Sci, Res Ctr Biomed & Robot Technol, Tehran, Iran
[4] Payambaran Hosp, MRI Imaging Ctr, Tehran, Iran
[5] Univ Tehran Med Sci, Imam Khomeini Hosp Complex, Imaging Ctr, Tehran, Iran
[6] Shahid Beheshti Univ Med Sci, Natl Res Inst TB & Lung Dis, Chron Resp Dis Res Ctr, Tehran, Iran
[7] Shahid Beheshti Univ Med Sci, Masih Daneshvari Hosp, PET CT & Cyclotron Ctr, Tehran, Iran
关键词
PET/MRI; Attenuation correction; Attenuation map; STE pulse sequence; FCM technique; PET/MRI; RECONSTRUCTION; ATLAS;
D O I
10.1007/s11307-015-0849-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study is to generate a four-class magnetic resonance imaging (MRI)-based attenuation map (mu-map) for attenuation correction of positron emission tomography (PET) data of the head area using a novel combination of short echo time (STE)/Dixon-MRI and a dedicated image segmentation method. MR images of the head area were acquired using STE and two-point Dixon sequences. mu-maps were derived from MRI images based on a fuzzy C-means (FCM) clustering method along with morphologic operations. Quantitative assessment was performed to evaluate generated MRI-based mu-maps compared to X-ray computed tomography (CT)-based mu-maps. The voxel-by-voxel comparison of MR-based and CT-based segmentation results yielded an average of more than 95 % for accuracy and specificity in the cortical bone, soft tissue, and air region. MRI-based mu-maps show a high correlation with those derived from CT scans (R (2) > 0.95). Results indicate that STE/Dixon-MRI data in combination with FCM-based segmentation yields precise MR-based mu-maps for PET attenuation correction in hybrid PET/MRI systems.
引用
收藏
页码:884 / 892
页数:9
相关论文
共 27 条
  • [1] Generation of a Four-Class Attenuation Map for MRI-Based Attenuation Correction of PET Data in the Head Area Using a Novel Combination of STE/Dixon-MRI and FCM Clustering
    Parisa Khateri
    Hamidreza Saligheh Rad
    Amir Homayoun Jafari
    Anahita Fathi Kazerooni
    Afshin Akbarzadeh
    Mohsen Shojae Moghadam
    Arvin Aryan
    Pardis Ghafarian
    Mohammad Reza Ay
    Molecular Imaging and Biology, 2015, 17 : 884 - 892
  • [2] Deep learning for Dixon MRI-based attenuation correction in PET/MRI of head and neck cancer patients
    Anders B. Olin
    Adam E. Hansen
    Jacob H. Rasmussen
    Björn Jakoby
    Anne K. Berthelsen
    Claes N. Ladefoged
    Andreas Kjær
    Barbara M. Fischer
    Flemming L. Andersen
    EJNMMI Physics, 9
  • [3] Deep learning for Dixon MRI-based attenuation correction in PET/MRI of head and neck cancer patients
    Olin, Anders B.
    Hansen, Adam E.
    Rasmussen, Jacob H.
    Jakoby, Bjoern
    Berthelsen, Anne K.
    Ladefoged, Claes N.
    Kjaer, Andreas
    Fischer, Barbara M.
    Andersen, Flemming L.
    EJNMMI PHYSICS, 2022, 9 (01)
  • [4] Attenuation Correction for PET/MRI Using MRI-based Pseudo CT
    Wang, Tonghe
    Lei, Yang
    Dong, Xue
    Higgins, Kristin
    Liu, Tian
    Curran, Walter J.
    Mao, Hui
    Nye, Jonathon A.
    Yang, Xiaofeng
    MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING, 2020, 11312
  • [5] MRI-Based Attenuation Correction for PET/MRI Using Ultrashort Echo Time Sequences
    Keereman, Vincent
    Fierens, Yves
    Broux, Tom
    De Deene, Yves
    Lonneux, Max
    Vandenberghe, Stefaan
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (05) : 812 - 818
  • [6] Standard MRI-based attenuation correction for PET/MRI phantoms: a novel concept using MRI-visible polymer
    Rausch, Ivo
    Valladares, Alejandra
    Sundar, Lalith Kumar Shiyam
    Beyer, Thomas
    Hacker, Marcus
    Meyerspeer, Martin
    Unger, Ewald
    EJNMMI PHYSICS, 2021, 8 (01)
  • [7] Standard MRI-based attenuation correction for PET/MRI phantoms: a novel concept using MRI-visible polymer
    Ivo Rausch
    Alejandra Valladares
    Lalith Kumar Shiyam Sundar
    Thomas Beyer
    Marcus Hacker
    Martin Meyerspeer
    Ewald Unger
    EJNMMI Physics, 8
  • [8] MRI-Based Attenuation Correction for PET/MRI Using Multiphase Level-Set Method
    An, Hyun Joon
    Seo, Seongho
    Kang, Hyejin
    Choi, Hongyoon
    Cheon, Gi Jeong
    Kim, Han-Joon
    Lee, Dong Soo
    Song, In Chan
    Kim, Yu Kyeong
    Lee, Jae Sung
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57 (04) : 587 - 593
  • [9] MRI-Based Attenuation Correction for PET/MRI: A Novel Approach Combining Pattern Recognition and Atlas Registration
    Hofmann, Matthias
    Steinke, Florian
    Scheel, Verena
    Charpiat, Guillaume
    Farquhar, Jason
    Aschoff, Philip
    Brady, Michael
    Schoelkopf, Bernhard
    Pichler, Bernd J.
    JOURNAL OF NUCLEAR MEDICINE, 2008, 49 (11) : 1875 - 1883
  • [10] MRI-based Attenuation Correction for PET/MRI: A Novel Approach Combining Anatomic Signature and Machine Learning
    Yang, Xiaofeng
    Lei, Yang
    Higgins, Kristin
    Mao, Hui
    Liu, Tian
    Shim, Hyunsuk
    Curran, Walter
    Nye, Jonathon
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59