Comparative analysis of airway scope and Macintosh laryngoscope for intubation primarily for cardiac arrest in prehospital setting

被引:52
作者
Arima, Takahiro [1 ]
Nagata, Osamu [2 ]
Miura, Takeshi [1 ]
Ikeda, Katsuki [1 ]
Mizushima, Tomoya [1 ]
Takahashi, Azusa [1 ]
Sakaida, Koji [1 ]
机构
[1] Funabashi Municipal Med Ctr, Emergency Dept, Funabashi, Chiba 2608677, Japan
[2] JFCR, Canc Inst Hosp, Dept Anesthesiol, Tokyo, Japan
关键词
CERVICAL-SPINE IMMOBILIZATION; MAC VIDEO LARYNGOSCOPE; TRACHEAL INTUBATION; ENDOTRACHEAL INTUBATION; EMERGENCY-DEPARTMENT; GLIDESCOPE(R); MANNEQUIN;
D O I
10.1016/j.ajem.2013.09.026
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Study objective: This study sought to determine and compare the utility of the Airway scope (AWS; Pentax Corporation, Tokyo, Japan) and the conventional Macintosh laryngoscope (MLS) for intubation in the prehospital setting. Methods: In this randomized controlled trial in the prehospital setting, the primary outcome was time required for intubation, and the secondary outcomes were ultimate success, first attempt success, and difficulty of intubation. The intent-to-treat principle was used to analyze time to intubation. Ultimate success was defined as intubation completed within 600 s regardless of the device ultimately used. Results: A total of 109 patients, primarily with cardiac arrest, were randomly assigned to the AWS or MLS arms. Median time (interquartile range) to intubation was 155 (71-216) s with the AWS versus 120 (60-170) s with the MLS (P=.095). Ultimate success rate was slightly lower with the AWS (96.4%) than with the MLS (100%) (P=.496), while the first attempt success rate was significantly lower (46% and 75%, respectively; P=.002). There was no significant difference in difficulty of intubation (P=.066). Multivariate logistic regression analysis revealed that cervical immobilization and oral contamination, such as vomit, was associated with first attempt success (odds ratio [95% confidence interval]: 0.11 [0.01-0.87] and 0.43 [0.18-0.99], respectively). Conclusion: Despite its many advantages seen in other settings, the AWS did not show superior efficacy to the MLS in relation to time required for intubation, ultimate or first attempt success rate, or difficulty level of intubation in the prehospital setting. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:40 / 43
页数:4
相关论文
共 17 条
[1]   The intubation difficulty scale (IDS) - Proposal and evaluation of a new score characterizing the complexity of endotracheal intubation [J].
Adnet, F ;
Borron, SW ;
Racine, SX ;
Clemessy, JL ;
Fournier, JL ;
Plaisance, P ;
Lapandry, C .
ANESTHESIOLOGY, 1997, 87 (06) :1290-1297
[2]   Tracheal intubation following training with the GlideScope® compared to direct laryngoscopy [J].
Ayoub, C. M. ;
Kanazi, G. E. ;
Al Alami, A. ;
Rameh, C. ;
El-Khatib, M. F. .
ANAESTHESIA, 2010, 65 (07) :674-678
[3]   Airway scope vs Macintosh laryngoscope during chest compressions on a fresh cadaver model [J].
Cho, Junho ;
Chung, Hyun Soo ;
Chung, Sung Pil ;
Kim, Young-Min ;
Cho, Young Soon .
AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2010, 28 (06) :741-744
[4]   Airway Scope and Macintosh Laryngoscope for Tracheal Intubation in Patients Lying on the Ground [J].
Komatsu, Ryu ;
Kamata, Kotoe ;
Sessler, Daniel I. ;
Ozaki, Makoto .
ANESTHESIA AND ANALGESIA, 2010, 111 (02) :427-431
[5]   Airway Scope and StyletScope for Tracheal Intubation in a Simulated Difficult Airway [J].
Komatsu, Ryu ;
Kamata, Kotoe ;
Hamada, Keiko ;
Sessler, Daniel I. ;
Ozaki, Makoto .
ANESTHESIA AND ANALGESIA, 2009, 108 (01) :273-279
[6]   The Impact of Video Laryngoscopy Use During Urgent Endotracheal Intubation in the Critically III [J].
Kory, Pierre ;
Guevarra, Keith ;
Mathew, Joseph P. ;
Hegde, Abhijith ;
Mayo, Paul H. .
ANESTHESIA AND ANALGESIA, 2013, 117 (01) :144-149
[7]   A paramedic study comparing the use of the Airtraq®, Airway Scope and Macintosh laryngoscopes in simulated prehospital airway scenarios [J].
Lewis, A. R. ;
Hodzovic, I. ;
Whelan, J. ;
Wilkes, A. R. ;
Bowler, I. ;
Whitfield, R. .
ANAESTHESIA, 2010, 65 (12) :1187-1193
[8]   Tracheal intubation with videolaryngoscopes in patients with cervical spine immobilization: a randomized trial of the Airway Scope® and the GlideScope® [J].
Liu, E. H. C. ;
Goy, R. W. L. ;
Tan, B. H. ;
Asai, T. .
BRITISH JOURNAL OF ANAESTHESIA, 2009, 103 (03) :446-451
[9]   Tracheal intubation in patients with cervical spine immobilization: a comparison of the Airwayscope®, LMA CTrach®, and the Macintosh laryngoscopes [J].
Malik, M. A. ;
Subramaniam, R. ;
Churasia, S. ;
Maharaj, C. H. ;
Harte, B. H. ;
Laffey, J. G. .
BRITISH JOURNAL OF ANAESTHESIA, 2009, 102 (05) :654-661
[10]   Comparison of the Glidescope®, the Pentax AWS®, and the Truview EVO2® with the Macintosh laryngoscope in experienced anaesthetists: a manikin study [J].
Malik, M. A. ;
O'Donoghue, C. ;
Carney, J. ;
Maharaj, C. H. ;
Harte, B. H. ;
Laffey, J. G. .
BRITISH JOURNAL OF ANAESTHESIA, 2009, 102 (01) :128-134