Anterior segment optical coherence tomography scanning protocols and corneal thickness repeatability

被引:12
|
作者
Fisher, Damien [1 ]
Collins, Michael J. [1 ]
Vincent, Stephen J. [1 ]
机构
[1] Queensland Univ Technol, Sch Optometry & Vis Sci, Contact Lens & Visual Opt Lab, Room B556,O Block,Victoria Pk Rd, Brisbane, Qld 4059, Australia
来源
CONTACT LENS & ANTERIOR EYE | 2020年 / 43卷 / 05期
关键词
Anterior segment OCT; Corneal thickness; Corneal oedema; Repeatability; LENS WEAR; KERATOCONUS; CLEARANCE; PENTACAM; PACHYMETRY; DIAGNOSIS; OCT;
D O I
10.1016/j.clae.2019.12.008
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To examine the influence of anterior segment optical coherence tomography imaging protocols on the intraobserver and intrasession repeatability of epithelial, stromal, and total corneal thickness measurements. Methods: Repeated anterior segment optical coherence tomography (AS-OCT) images (Spectralis, Heidelberg) were obtained from 15 adults using single 8.3 mm wide horizontal line scans with an average of 2, 10, 20, 30, 50 and 100 B-scans. Volumetric scans consisting of nine 8.3 mm horizontal line scans encompassing a 1.3 mm vertical region were also captured (with 20 B-scans per line scan). Single point thickness measures (at the normal to the tangent of the anterior corneal surface) were compared with thickness measures averaged over the central 6 mm. The impact of B-scan averaging and intraobserver variability were examined for single line scans. For volumetric scans, the impact of the number of line scans upon intraobserver and intrasession variability were calculated. Results: Intraobserver repeatability did not vary significantly as a function of the number of averaged B-scans per line scan, but was lowest for 20-30 averaged B scans. For volumetric scans, increasing the number of line scans did increase scan duration (p < 0.001), with minimal impact upon the average scan quality index (p = 0.06). Averaging more than 3 line scans did not significantly improve intraobserver or intrasession repeatability for either single point or average thickness measurements. Conclusion: AS-OCT volumetric scans with 3 lines each consisting of 20 B-scans with measurements averaged over a central 6 mm of the cornea provide highly repeatable measures of epithelial, stromal and total corneal thickness (95 % LoA <= +/- 3.2 mu m for intraobserver repeatability and <= +/- 3.7 mu m for intrasession repeatability). This scanning protocol can provide reliable information when monitoring subtle changes in corneal thickness.
引用
收藏
页码:433 / 440
页数:8
相关论文
共 50 条
  • [41] Corneal stromal demarcation line after 4 protocols of corneal crosslinking in keratoconus determined with anterior segment optical coherence tomography
    Spadea, Leopoldo
    Di Genova, Lucia
    Tonti, Emanuele
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (05): : 596 - 602
  • [42] Corneal stromal demarcation line after 4 protocols of corneal crosslinking in keratoconus determined with anterior segment optical coherence tomography
    Torres-Netto, Emilio A.
    Randleman, J. Bradley
    Hafezi, Nikki L.
    Hafezi, Farhad
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (12): : 1535 - 1535
  • [43] Assessment of Intrastromal Corneal Ring Segment Position With Anterior Segment Optical Coherence Tomography
    Gorgun, Ebru
    Kucumen, Raciha Beril
    Yenerel, Nursal Melda
    Ciftci, Ferda
    OPHTHALMIC SURGERY LASERS & IMAGING, 2012, 43 (03) : 214 - 221
  • [44] Measurement of LASIK Flap Thickness With Anterior Segment Optical Coherence Tomography
    Cheng, Arthur C. K.
    Ho, Thomas
    Lau, Silvania
    Wong, Amy L.
    Leung, Chris
    Lam, Dennis S. C.
    JOURNAL OF REFRACTIVE SURGERY, 2008, 24 (09) : 879 - 884
  • [45] Age-Related Changes in Human Corneal Epithelial Thickness Measured With Anterior Segment Optical Coherence Tomography
    Yang, Yujing
    Hong, Jiaxu
    Deng, Sophie X.
    Xu, Jianjiang
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (08) : 5032 - 5038
  • [46] Central Corneal Thickness and Anterior Scleral Thickness in Korean Patients With Open-angle Glaucoma: An Anterior Segment Optical Coherence Tomography Study
    Yoo, Chungkwon
    Eom, Young Sub
    Suh, Young-Woo
    Kim, Yong Yeon
    JOURNAL OF GLAUCOMA, 2011, 20 (02) : 95 - 99
  • [47] Anterior segment optical coherence tomography
    Ang, Marcus
    Baskaran, Mani
    Werkmeister, Rene M.
    Chua, Jacqueline
    Schmidl, Doreen
    dos Santos, Valentin Aranha
    Garhoefer, Gerhard
    Mehta, Jodhbir S.
    Schmetterer, Leopold
    PROGRESS IN RETINAL AND EYE RESEARCH, 2018, 66 : 132 - 156
  • [48] Optical coherence tomography of the anterior segment
    Simpson, Trefford
    Optom, Dip
    Fonn, Desmond
    Optom, Dip
    Optom, M.
    OCULAR SURFACE, 2008, 6 (03): : 117 - 127
  • [49] Relations Among Corneal Curvature, Thickness, and Volume in Keratoconus as Evaluated by Anterior Segment-Optical Coherence Tomography
    Morishige, Naoyuki
    Magome, Kazuyoshi
    Ueno, Akifumi
    Matsui, Taka-Aki
    Nishida, Teruo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (12) : 3794 - 3802
  • [50] Corneal thickness mapping by 3D swept-source anterior segment optical coherence tomography
    Neri, Alberto
    Malori, Marianna
    Scaroni, Patrizia
    Leaci, Rosachiara
    Delfini, Elisabetta
    Macaluso, Claudio
    ACTA OPHTHALMOLOGICA, 2012, 90 (06) : e452 - e457