Anterior segment optical coherence tomography scanning protocols and corneal thickness repeatability

被引:12
|
作者
Fisher, Damien [1 ]
Collins, Michael J. [1 ]
Vincent, Stephen J. [1 ]
机构
[1] Queensland Univ Technol, Sch Optometry & Vis Sci, Contact Lens & Visual Opt Lab, Room B556,O Block,Victoria Pk Rd, Brisbane, Qld 4059, Australia
来源
CONTACT LENS & ANTERIOR EYE | 2020年 / 43卷 / 05期
关键词
Anterior segment OCT; Corneal thickness; Corneal oedema; Repeatability; LENS WEAR; KERATOCONUS; CLEARANCE; PENTACAM; PACHYMETRY; DIAGNOSIS; OCT;
D O I
10.1016/j.clae.2019.12.008
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To examine the influence of anterior segment optical coherence tomography imaging protocols on the intraobserver and intrasession repeatability of epithelial, stromal, and total corneal thickness measurements. Methods: Repeated anterior segment optical coherence tomography (AS-OCT) images (Spectralis, Heidelberg) were obtained from 15 adults using single 8.3 mm wide horizontal line scans with an average of 2, 10, 20, 30, 50 and 100 B-scans. Volumetric scans consisting of nine 8.3 mm horizontal line scans encompassing a 1.3 mm vertical region were also captured (with 20 B-scans per line scan). Single point thickness measures (at the normal to the tangent of the anterior corneal surface) were compared with thickness measures averaged over the central 6 mm. The impact of B-scan averaging and intraobserver variability were examined for single line scans. For volumetric scans, the impact of the number of line scans upon intraobserver and intrasession variability were calculated. Results: Intraobserver repeatability did not vary significantly as a function of the number of averaged B-scans per line scan, but was lowest for 20-30 averaged B scans. For volumetric scans, increasing the number of line scans did increase scan duration (p < 0.001), with minimal impact upon the average scan quality index (p = 0.06). Averaging more than 3 line scans did not significantly improve intraobserver or intrasession repeatability for either single point or average thickness measurements. Conclusion: AS-OCT volumetric scans with 3 lines each consisting of 20 B-scans with measurements averaged over a central 6 mm of the cornea provide highly repeatable measures of epithelial, stromal and total corneal thickness (95 % LoA <= +/- 3.2 mu m for intraobserver repeatability and <= +/- 3.7 mu m for intrasession repeatability). This scanning protocol can provide reliable information when monitoring subtle changes in corneal thickness.
引用
收藏
页码:433 / 440
页数:8
相关论文
共 50 条
  • [31] Age-related differences in corneal epithelial thickness measurements with anterior segment optical coherence tomography
    Kim, Bong Jun
    Ryu, Ik-Hee
    Kim, Sun Woong
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2016, 60 (05) : 357 - 364
  • [32] Comparison of central corneal thickness in corneal edema by ultrasound pachymetry, specular microscopy, and anterior segment optical coherence tomography
    Artuc, Tuncay
    Batur, Muhammed
    SAUDI JOURNAL OF OPHTHALMOLOGY, 2023, 37 (01) : 1 - 5
  • [33] Investigation of the Sectorized Corneal Thickness of Eyes With Corneal Endothelial Dysfunction Using Anterior-Segment Optical Coherence Tomography
    Omoto, Takashi
    Kim, Minjae
    Goto, Hiroki
    Abe, Yuito
    Ono, Takashi
    Taketani, Yukako
    Toyono, Tetsuya
    Yoshida, Junko
    Usui, Tomohiko
    Yamagami, Satoru
    Aihara, Makoto
    Miyai, Takashi
    CORNEA, 2023, 42 (06) : 714 - 718
  • [34] Utility of Anterior Segment Optical Coherence Tomography in the Management of Corneal Transplantation
    Takefumi Yamaguchi
    Jun Shimazaki
    Current Ophthalmology Reports, 2016, 4 (4) : 252 - 264
  • [35] Indications for intraoperative anterior segment optical coherence tomography in corneal surgery
    Stefan J. Lang
    Sonja Heinzelmann
    Daniel Böhringer
    Thomas Reinhard
    Philip Maier
    International Ophthalmology, 2020, 40 : 2617 - 2625
  • [36] Indications for intraoperative anterior segment optical coherence tomography in corneal surgery
    Lang, Stefan J.
    Heinzelmann, Sonja
    Boehringer, Daniel
    Reinhard, Thomas
    Maier, Philip
    INTERNATIONAL OPHTHALMOLOGY, 2020, 40 (10) : 2617 - 2625
  • [37] Anterior Segment Optical Coherence Tomography Findings in Corneal Blood Staining
    Mansoori, Tarannum
    Srirampur, Arjun
    JOURNAL OF CURRENT OPHTHALMOLOGY, 2021, 33 (01): : 95 - 95
  • [38] Comparison of a new anterior segment optical coherence tomography and Oculus Pentacam for measurement of anterior chamber depth and corneal thickness
    Li, Xuepei
    Zhou, Yijing
    Young, Charlotte Aimee
    Chen, Aiming
    Jin, Guangming
    Zheng, Danying
    ANNALS OF TRANSLATIONAL MEDICINE, 2020, 8 (14)
  • [39] Reliability of corneal topographic analysis with anterior segment optical coherence tomography
    Huang, Jinhai
    Wang, Qinmei
    Pesudovs, Konrad
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (03): : 560 - 560
  • [40] Anterior Segment Optical Coherence Tomography Features of Acute Corneal Hydrops
    Basu, Sayan
    Vaddavalli, Pravin K.
    Vemuganti, Geeta K.
    Ali, Md Hasnat
    Murthy, Somasheila I.
    CORNEA, 2012, 31 (05) : 479 - 485