Anterior segment optical coherence tomography scanning protocols and corneal thickness repeatability

被引:12
|
作者
Fisher, Damien [1 ]
Collins, Michael J. [1 ]
Vincent, Stephen J. [1 ]
机构
[1] Queensland Univ Technol, Sch Optometry & Vis Sci, Contact Lens & Visual Opt Lab, Room B556,O Block,Victoria Pk Rd, Brisbane, Qld 4059, Australia
来源
CONTACT LENS & ANTERIOR EYE | 2020年 / 43卷 / 05期
关键词
Anterior segment OCT; Corneal thickness; Corneal oedema; Repeatability; LENS WEAR; KERATOCONUS; CLEARANCE; PENTACAM; PACHYMETRY; DIAGNOSIS; OCT;
D O I
10.1016/j.clae.2019.12.008
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To examine the influence of anterior segment optical coherence tomography imaging protocols on the intraobserver and intrasession repeatability of epithelial, stromal, and total corneal thickness measurements. Methods: Repeated anterior segment optical coherence tomography (AS-OCT) images (Spectralis, Heidelberg) were obtained from 15 adults using single 8.3 mm wide horizontal line scans with an average of 2, 10, 20, 30, 50 and 100 B-scans. Volumetric scans consisting of nine 8.3 mm horizontal line scans encompassing a 1.3 mm vertical region were also captured (with 20 B-scans per line scan). Single point thickness measures (at the normal to the tangent of the anterior corneal surface) were compared with thickness measures averaged over the central 6 mm. The impact of B-scan averaging and intraobserver variability were examined for single line scans. For volumetric scans, the impact of the number of line scans upon intraobserver and intrasession variability were calculated. Results: Intraobserver repeatability did not vary significantly as a function of the number of averaged B-scans per line scan, but was lowest for 20-30 averaged B scans. For volumetric scans, increasing the number of line scans did increase scan duration (p < 0.001), with minimal impact upon the average scan quality index (p = 0.06). Averaging more than 3 line scans did not significantly improve intraobserver or intrasession repeatability for either single point or average thickness measurements. Conclusion: AS-OCT volumetric scans with 3 lines each consisting of 20 B-scans with measurements averaged over a central 6 mm of the cornea provide highly repeatable measures of epithelial, stromal and total corneal thickness (95 % LoA <= +/- 3.2 mu m for intraobserver repeatability and <= +/- 3.7 mu m for intrasession repeatability). This scanning protocol can provide reliable information when monitoring subtle changes in corneal thickness.
引用
收藏
页码:433 / 440
页数:8
相关论文
共 50 条
  • [21] Comparison of central corneal thickness using anterior segment optical coherence tomography vs ultrasound pachymetry
    Kim, Hanna Y.
    Budenz, Donald L.
    Lee, Pak S.
    Feuer, William J.
    Barton, Keith
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2008, 145 (02) : 228 - 232
  • [22] Effects of topical antiglaucomatous medications on central corneal epithelial thickness by anterior segment optical coherence tomography
    Dogan, Emine
    Cakir, Burcin Koklu
    Aksoy, Nilgun Ozkan
    Celik, Erkan
    Erkorkmaz, Unal
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2020, 30 (06) : 1519 - 1524
  • [23] Evaluation of corneal epithelial thickness in glaucomatous patients using anterior-segment optical coherence tomography
    Montorio, Daniela
    Cennamo, Gilda
    Breve, Maria A.
    Fiore, Ugo
    Reibaldi, Michele
    Morra, Vincenzo Brescia
    Cennamo, Giovanni
    JOURNAL OF BIOPHOTONICS, 2020, 13 (01)
  • [24] Comparison of central corneal thickness measurements by visante anterior segment optical coherence tomography with ultrasound pachymetry
    Zhao, Paul S.
    Wong, Tien Yin
    Wong, Wan-Ling
    Saw, Seang-Mei
    Aung, Tin
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 143 (06) : 1047 - 1049
  • [25] Corneal Thickness and Volume Measurements by Swept Source Anterior Segment Optical Coherence Tomography in Normal Subjects
    Fukuda, Reina
    Usui, Tomohiko
    Miyai, Takashi
    Mori, Yosai
    Miyata, Kazunori
    Amano, Shiro
    CURRENT EYE RESEARCH, 2013, 38 (05) : 531 - 536
  • [26] Age-related differences in corneal epithelial thickness measurements with anterior segment optical coherence tomography
    Bong Jun Kim
    Ik-Hee Ryu
    Sun Woong Kim
    Japanese Journal of Ophthalmology, 2016, 60 : 357 - 364
  • [27] Anterior segment optical coherence tomography and ultrasound biomicroscopy for measuring thickness of corneal and bulbar conjunctival tumours
    Lauwers, Noemie
    Janssens, Katleen
    Mertens, Michelle
    Mathysen, Danny
    Lammens, Martin
    de Keizer, Rob J. W.
    De Groot, Veva
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2022, 106 (06) : 760 - 764
  • [28] Age-Related Changes of Human Corneal Epithelial Thickness by Anterior Segment Optical Coherence Tomography
    Yang, Yujing
    Xu, JianJiang
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [29] Measurement of corneal and limbal epithelial thickness by anterior segment optical coherence tomography and in vivo confocal microscopy
    Qihua Le
    Yan Chen
    Yujing Yang
    Jianjiang Xu
    BMC Ophthalmology, 16
  • [30] Measurement of corneal and limbal epithelial thickness by anterior segment optical coherence tomography and in vivo confocal microscopy
    Le, Qihua
    Chen, Yan
    Yang, Yujing
    Xu, Jianjiang
    BMC OPHTHALMOLOGY, 2016, 16