Anterior segment optical coherence tomography scanning protocols and corneal thickness repeatability

被引:12
作者
Fisher, Damien [1 ]
Collins, Michael J. [1 ]
Vincent, Stephen J. [1 ]
机构
[1] Queensland Univ Technol, Sch Optometry & Vis Sci, Contact Lens & Visual Opt Lab, Room B556,O Block,Victoria Pk Rd, Brisbane, Qld 4059, Australia
关键词
Anterior segment OCT; Corneal thickness; Corneal oedema; Repeatability; LENS WEAR; KERATOCONUS; CLEARANCE; PENTACAM; PACHYMETRY; DIAGNOSIS; OCT;
D O I
10.1016/j.clae.2019.12.008
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To examine the influence of anterior segment optical coherence tomography imaging protocols on the intraobserver and intrasession repeatability of epithelial, stromal, and total corneal thickness measurements. Methods: Repeated anterior segment optical coherence tomography (AS-OCT) images (Spectralis, Heidelberg) were obtained from 15 adults using single 8.3 mm wide horizontal line scans with an average of 2, 10, 20, 30, 50 and 100 B-scans. Volumetric scans consisting of nine 8.3 mm horizontal line scans encompassing a 1.3 mm vertical region were also captured (with 20 B-scans per line scan). Single point thickness measures (at the normal to the tangent of the anterior corneal surface) were compared with thickness measures averaged over the central 6 mm. The impact of B-scan averaging and intraobserver variability were examined for single line scans. For volumetric scans, the impact of the number of line scans upon intraobserver and intrasession variability were calculated. Results: Intraobserver repeatability did not vary significantly as a function of the number of averaged B-scans per line scan, but was lowest for 20-30 averaged B scans. For volumetric scans, increasing the number of line scans did increase scan duration (p < 0.001), with minimal impact upon the average scan quality index (p = 0.06). Averaging more than 3 line scans did not significantly improve intraobserver or intrasession repeatability for either single point or average thickness measurements. Conclusion: AS-OCT volumetric scans with 3 lines each consisting of 20 B-scans with measurements averaged over a central 6 mm of the cornea provide highly repeatable measures of epithelial, stromal and total corneal thickness (95 % LoA <= +/- 3.2 mu m for intraobserver repeatability and <= +/- 3.7 mu m for intrasession repeatability). This scanning protocol can provide reliable information when monitoring subtle changes in corneal thickness.
引用
收藏
页码:433 / 440
页数:8
相关论文
共 56 条
  • [1] Morphological changes in the conjunctiva, episclera and sclera following short-term miniscleral contact lens wear in rigid lens neophytes
    Alonso-Caneiro, David
    Vincent, Stephen J.
    Collins, Michael J.
    [J]. CONTACT LENS & ANTERIOR EYE, 2016, 39 (01) : 53 - 61
  • [2] Speckle reduction in optical coherence tomography imaging by affine-motion image registration
    Alonso-Caneiro, David
    Read, Scott A.
    Collins, Michael J.
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (11)
  • [3] Anterior segment optical coherence tomography
    Ang, Marcus
    Baskaran, Mani
    Werkmeister, Rene M.
    Chua, Jacqueline
    Schmidl, Doreen
    dos Santos, Valentin Aranha
    Garhoefer, Gerhard
    Mehta, Jodhbir S.
    Schmetterer, Leopold
    [J]. PROGRESS IN RETINAL AND EYE RESEARCH, 2018, 66 : 132 - 156
  • [4] [Anonymous], 2016, SPECTR ANT SEGM MOD
  • [5] Arlt C., 2015, THESIS
  • [6] Scleral topography analysed by optical coherence tomography
    Bandlitz, Stefan
    Baeumer, Joachim
    Conrad, Uwe
    Wolffsohn, James
    [J]. CONTACT LENS & ANTERIOR EYE, 2017, 40 (04) : 242 - 247
  • [7] Change in over-refraction after scleral lens settling on average corneas
    Bray, Chelsea
    Britton, Stephanie
    Yeung, Debby
    Haines, Lacey
    Sorbara, Luigina
    [J]. OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2017, 37 (04) : 467 - 472
  • [8] Exact Parametric Confidence Intervals for Bland-Altman Limits of Agreement
    Carkeet, Andrew
    [J]. OPTOMETRY AND VISION SCIENCE, 2015, 92 (03) : E71 - E80
  • [9] Pupil Tracking for Real-Time Motion Corrected Anterior Segment Optical Coherence Tomography
    Carrasco-Zevallos, Oscar M.
    Nankivil, Derek
    Viehland, Christian
    Keller, Brenton
    Izatt, Joseph A.
    [J]. PLOS ONE, 2016, 11 (08):
  • [10] Courey C, 2018, J CONT LENS RES SCI, V2