Anterior segment optical coherence tomography scanning protocols and corneal thickness repeatability

被引:12
|
作者
Fisher, Damien [1 ]
Collins, Michael J. [1 ]
Vincent, Stephen J. [1 ]
机构
[1] Queensland Univ Technol, Sch Optometry & Vis Sci, Contact Lens & Visual Opt Lab, Room B556,O Block,Victoria Pk Rd, Brisbane, Qld 4059, Australia
来源
CONTACT LENS & ANTERIOR EYE | 2020年 / 43卷 / 05期
关键词
Anterior segment OCT; Corneal thickness; Corneal oedema; Repeatability; LENS WEAR; KERATOCONUS; CLEARANCE; PENTACAM; PACHYMETRY; DIAGNOSIS; OCT;
D O I
10.1016/j.clae.2019.12.008
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To examine the influence of anterior segment optical coherence tomography imaging protocols on the intraobserver and intrasession repeatability of epithelial, stromal, and total corneal thickness measurements. Methods: Repeated anterior segment optical coherence tomography (AS-OCT) images (Spectralis, Heidelberg) were obtained from 15 adults using single 8.3 mm wide horizontal line scans with an average of 2, 10, 20, 30, 50 and 100 B-scans. Volumetric scans consisting of nine 8.3 mm horizontal line scans encompassing a 1.3 mm vertical region were also captured (with 20 B-scans per line scan). Single point thickness measures (at the normal to the tangent of the anterior corneal surface) were compared with thickness measures averaged over the central 6 mm. The impact of B-scan averaging and intraobserver variability were examined for single line scans. For volumetric scans, the impact of the number of line scans upon intraobserver and intrasession variability were calculated. Results: Intraobserver repeatability did not vary significantly as a function of the number of averaged B-scans per line scan, but was lowest for 20-30 averaged B scans. For volumetric scans, increasing the number of line scans did increase scan duration (p < 0.001), with minimal impact upon the average scan quality index (p = 0.06). Averaging more than 3 line scans did not significantly improve intraobserver or intrasession repeatability for either single point or average thickness measurements. Conclusion: AS-OCT volumetric scans with 3 lines each consisting of 20 B-scans with measurements averaged over a central 6 mm of the cornea provide highly repeatable measures of epithelial, stromal and total corneal thickness (95 % LoA <= +/- 3.2 mu m for intraobserver repeatability and <= +/- 3.7 mu m for intrasession repeatability). This scanning protocol can provide reliable information when monitoring subtle changes in corneal thickness.
引用
收藏
页码:433 / 440
页数:8
相关论文
共 50 条
  • [1] Repeatability of corneal and epithelial thickness measurements with anterior segment optical coherence tomography in keratoconus
    Li, Ye
    Gokul, Akilesh
    McGhee, Charles
    Ziaei, Mohammed
    PLOS ONE, 2021, 16 (06):
  • [2] Repeatability of corneal and epithelial thickness measurements with anterior segment optical coherence tomography in keratoconus
    Li, Ye
    Gokul, Akilesh
    McGhee, Charles
    Ziaei, Mo
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 49 (08): : 884 - 885
  • [3] Repeatability and reproducibility of corneal thickness measurements by optical coherence tomography
    Muscat, S
    McKay, N
    Parks, S
    Kemp, E
    Keating, D
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 (06) : 1791 - 1795
  • [4] Anterior Segment Optical Coherence Tomography in Corneal Ulcers
    Sitnik, H.
    Imshenetskaya, T.
    8TH INTERNATIONAL SYMPOSIUM ON OCULAR PHARMACOLOGY AND THERAPEUTICS - ISOPT, 2009, : 181 - 186
  • [5] Changes in Corneal Thickness in Congenital Glaucoma, Using Anterior Segment Optical Coherence Tomography
    Lee, Chaeyeon
    Lee, Eun Jung
    Jang, Yoonkyung
    Han, Jong Chul
    Kee, Chang Won
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2022, 63 (08): : 692 - 699
  • [6] Distribution of corneal thickness in the Tunisian population: Study by anterior segment optical coherence tomography
    Ouederni, M.
    Mrad, I
    Sassi, H.
    Bellaaj, M.
    Letaief, H.
    Ayedi, O.
    Cheour, M.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2019, 42 (08): : 874 - 879
  • [7] The repeatability of corneal and corneal epithelial thickness measurements using optical coherence tomography
    Sin, Sokpheaktra
    Simpson, Trefford L.
    OPTOMETRY AND VISION SCIENCE, 2006, 83 (06) : 360 - 365
  • [8] Evaluation of Scanning Protocols for Imaging the Anterior Chamber Angle With Anterior Segment-Optical Coherence Tomography
    Khor, Wei-Boon
    Sakata, Lisandro M.
    Friedman, David S.
    Narayanaswamy, Arun
    Lavanya, Raghavan
    Perera, Shamira A.
    Aung, Tin
    JOURNAL OF GLAUCOMA, 2010, 19 (06) : 365 - 368
  • [9] Corneal sublayer thickness in patients with pseudoexfoliation syndrome evaluated by anterior segment optical coherence tomography
    Tekce, Abdulhakim
    Gulmez, Mehmet
    INTERNATIONAL OPHTHALMOLOGY, 2020, 40 (03) : 563 - 570
  • [10] Corneal graphite deposit on anterior segment optical coherence tomography
    Vijitha, V. S.
    Kapoor, Anasua Ganguly
    Mohammed, Mansoor
    Roy, Aravind
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2019, 67 (07) : 1178 - 1178