Anterior segment optical coherence tomography scanning protocols and corneal thickness repeatability

被引:12
作者
Fisher, Damien [1 ]
Collins, Michael J. [1 ]
Vincent, Stephen J. [1 ]
机构
[1] Queensland Univ Technol, Sch Optometry & Vis Sci, Contact Lens & Visual Opt Lab, Room B556,O Block,Victoria Pk Rd, Brisbane, Qld 4059, Australia
关键词
Anterior segment OCT; Corneal thickness; Corneal oedema; Repeatability; LENS WEAR; KERATOCONUS; CLEARANCE; PENTACAM; PACHYMETRY; DIAGNOSIS; OCT;
D O I
10.1016/j.clae.2019.12.008
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To examine the influence of anterior segment optical coherence tomography imaging protocols on the intraobserver and intrasession repeatability of epithelial, stromal, and total corneal thickness measurements. Methods: Repeated anterior segment optical coherence tomography (AS-OCT) images (Spectralis, Heidelberg) were obtained from 15 adults using single 8.3 mm wide horizontal line scans with an average of 2, 10, 20, 30, 50 and 100 B-scans. Volumetric scans consisting of nine 8.3 mm horizontal line scans encompassing a 1.3 mm vertical region were also captured (with 20 B-scans per line scan). Single point thickness measures (at the normal to the tangent of the anterior corneal surface) were compared with thickness measures averaged over the central 6 mm. The impact of B-scan averaging and intraobserver variability were examined for single line scans. For volumetric scans, the impact of the number of line scans upon intraobserver and intrasession variability were calculated. Results: Intraobserver repeatability did not vary significantly as a function of the number of averaged B-scans per line scan, but was lowest for 20-30 averaged B scans. For volumetric scans, increasing the number of line scans did increase scan duration (p < 0.001), with minimal impact upon the average scan quality index (p = 0.06). Averaging more than 3 line scans did not significantly improve intraobserver or intrasession repeatability for either single point or average thickness measurements. Conclusion: AS-OCT volumetric scans with 3 lines each consisting of 20 B-scans with measurements averaged over a central 6 mm of the cornea provide highly repeatable measures of epithelial, stromal and total corneal thickness (95 % LoA <= +/- 3.2 mu m for intraobserver repeatability and <= +/- 3.7 mu m for intrasession repeatability). This scanning protocol can provide reliable information when monitoring subtle changes in corneal thickness.
引用
收藏
页码:433 / 440
页数:8
相关论文
共 56 条
[1]   Morphological changes in the conjunctiva, episclera and sclera following short-term miniscleral contact lens wear in rigid lens neophytes [J].
Alonso-Caneiro, David ;
Vincent, Stephen J. ;
Collins, Michael J. .
CONTACT LENS & ANTERIOR EYE, 2016, 39 (01) :53-61
[2]   Speckle reduction in optical coherence tomography imaging by affine-motion image registration [J].
Alonso-Caneiro, David ;
Read, Scott A. ;
Collins, Michael J. .
JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (11)
[3]   Anterior segment optical coherence tomography [J].
Ang, Marcus ;
Baskaran, Mani ;
Werkmeister, Rene M. ;
Chua, Jacqueline ;
Schmidl, Doreen ;
dos Santos, Valentin Aranha ;
Garhoefer, Gerhard ;
Mehta, Jodhbir S. ;
Schmetterer, Leopold .
PROGRESS IN RETINAL AND EYE RESEARCH, 2018, 66 :132-156
[4]  
[Anonymous], 2016, SPECTR ANT SEGM MOD
[5]  
Arlt C., 2015, THESIS
[6]   Scleral topography analysed by optical coherence tomography [J].
Bandlitz, Stefan ;
Baeumer, Joachim ;
Conrad, Uwe ;
Wolffsohn, James .
CONTACT LENS & ANTERIOR EYE, 2017, 40 (04) :242-247
[7]   Change in over-refraction after scleral lens settling on average corneas [J].
Bray, Chelsea ;
Britton, Stephanie ;
Yeung, Debby ;
Haines, Lacey ;
Sorbara, Luigina .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2017, 37 (04) :467-472
[8]   Exact Parametric Confidence Intervals for Bland-Altman Limits of Agreement [J].
Carkeet, Andrew .
OPTOMETRY AND VISION SCIENCE, 2015, 92 (03) :E71-E80
[9]   Pupil Tracking for Real-Time Motion Corrected Anterior Segment Optical Coherence Tomography [J].
Carrasco-Zevallos, Oscar M. ;
Nankivil, Derek ;
Viehland, Christian ;
Keller, Brenton ;
Izatt, Joseph A. .
PLOS ONE, 2016, 11 (08)
[10]  
Courey C, 2018, J CONT LENS RES SCI, V2