Inlet port positioning for a miniaturized centrifugal blood pump

被引:3
作者
Takano, T
Schulte-Eistrup, S
Kawahito, S
Maeda, T
Nonaka, K
Linneweber, J
Glueck, J
Fujisawa, A
Makinouchi, K
Yokokawa, M
Nosé, Y
机构
[1] Baylor Coll Med, Dept Surg, Houston, TX 77030 USA
[2] Kyocera Corp, Kyoto, Japan
关键词
centrifugal blood pump; inlet port position; left ventricular assist device; hemolysis; hydraulic performance;
D O I
10.1046/j.1525-1594.2002.06851.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We are developing the Baylor-Kyocera KP implantable centrifugal blood pump for small sized adult and pediatric patients. This pump eccentrically positions the inlet port, which eliminates flow stagnation around the top pivot bearing. The inlet port design is important because it may vary the inlet orifice pressure on the top housing and change hydraulic performance and hemolytic characteristics. The pressure distribution inside the KP pump was assessed by a computational fluid dynamic (CFD) analysis with 2.7 x 10(5) elements and 3.16 x 10(5) nodes. Hydraulic performance and hemolysis were evaluated with 3 different pump housings, which had 3.8, 4.5, and 6.1 mm offset inlet ports from the center in a mock circuit. The CFD analysis revealed that the pressure gradually increased from the center toward the peripheral. The pressure difference between the 3.8 to 6.1 mm offsets was less than 600 Pa. The hydraulic performance did not drastically change at 3.8, 4.5, and 6.1 mm offset from the center. However, the hemolysis increased with the increase of the port offset from 0.0080 +/- 0.0048 to 0.054 +/- 0.028 g/100 L. The inlet port positioning is important to attain less blood trauma in this small Gyro centrifugal blood pump. The preferable position of the inlet port is less than 4.5 mm offset from the center.
引用
收藏
页码:45 / 48
页数:4
相关论文
共 6 条
[1]   DEVELOPMENT OF THE BAYLOR NASA AXIAL-FLOW VENTRICULAR ASSIST DEVICE - IN-VITRO PERFORMANCE AND SYSTEMATIC HEMOLYSIS TEST-RESULTS [J].
MIZUGUCHI, K ;
DAMM, GA ;
BOZEMAN, RJ ;
AKKERMAN, JW ;
ABER, GS ;
SVEJKOVSKY, PA ;
BACAK, JW ;
ORIME, Y ;
TAKATANI, S ;
NOSE, Y ;
NOON, GP ;
DEBAKEY, ME .
ARTIFICIAL ORGANS, 1994, 18 (01) :32-43
[2]   Design and development strategy for the rotary blood pump [J].
Nose, Y .
ARTIFICIAL ORGANS, 1998, 22 (06) :438-446
[3]   SELECTION CRITERIA FOR PLACEMENT OF LEFT-VENTRICULAR ASSIST DEVICES [J].
OZ, MC ;
ROSE, EA ;
LEVIN, HR .
AMERICAN HEART JOURNAL, 1995, 129 (01) :173-177
[4]  
Takami Y, 1997, ARTIF ORGANS, V21, P312
[5]   Development of an antithrombogenic and antitraumatic blood pump:: The Gyro C1E3 [J].
Takano, T ;
Nakata, K ;
Yoshikawa, M ;
Maeda, T ;
Glueck, J ;
Fujisawa, A ;
Makinouchi, K ;
Yokokawa, M ;
Murabayashi, S ;
Nosé, Y .
ASAIO JOURNAL, 2000, 46 (01) :123-127
[6]   Feasibility of a tiny Gyro centrifugal pump as an implantable ventricular assist device [J].
Yoshikawa, M ;
Nakata, K ;
Ohtsuka, G ;
Takano, T ;
Glueck, J ;
Fujisawa, A ;
Makinouchi, K ;
Yokokawa, M ;
Nosé, Y .
ARTIFICIAL ORGANS, 1999, 23 (08) :774-779