Mechanics and failure characteristics of hybrid fiber-reinforced concrete (HyFRC) composites with longitudinal steel reinforcement

被引:29
作者
Nguyen, Wilson [1 ,4 ]
Bandelt, Matthew J. [2 ]
Trono, William [1 ]
Billington, Sarah L. [3 ]
Ostertag, Claudia P. [1 ]
机构
[1] Univ Calif Berkeley, Dept Civil & Environm Engn, Berkeley, CA 94720 USA
[2] New Jersey Inst Technol, John A Reif Jr Dept Civil & Environm Engn, Newark, NJ 07102 USA
[3] Stanford Univ, Dept Civil & Environm Engn, Stanford, CA 94305 USA
[4] Wiss Janney Elstner & Associates Inc, Emeryville, CA 94608 USA
基金
美国国家科学基金会;
关键词
High-performance fiber-reinforced cementitious composites; HPFRCC; Tension stiffening; Strain localization; Strain hardening; Inelastic; Pull out; Bond-slip; Splitting crack; Reinforcement ratio; PERFORMANCE; BEHAVIOR; CRACKING; DUCTILITY; MEMBERS;
D O I
10.1016/j.engstruct.2018.12.087
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
While the properties of hybrid fiber-reinforced concrete (HyFRC) have been well-reported in the literature, the behavior of reinforced HyFRC (i.e., HyFRC with embedded steel rebar) is less understood. This paper investigates the mechanics and failure characteristics of reinforced HyFRC under direct tension. Samples with a low longitudinal steel reinforcement ratio were studied to evaluate the feasibility of reducing rebar congestion in structural applications through the use of fiber-reinforced concrete. Although reinforced HyFRC forms multiple cracking sites when loaded, rebar strain and HyFRC crack opening are generally concentrated at a single location under post-yield displacements. The onset of rebar plastic deformation and the exhaustion of fibers' bridging load capacity are coincident events at a dominant crack. For a cracked reinforced HyFRC section to strengthen, the magnitude of load resistance increase from strain hardening rebar must exceed the magnitude of load resistance decrease from fiber pull-out processes. Comparisons are made with studies reported in the literature to demonstrate how longitudinal reinforcement ratio and fiber type influence cracking behavior and ultimate strain capacity. The research presented herein has far-reaching impacts on the structural design of all types of reinforced fiber-reinforced concrete materials detailed for a ductile response under large displacements.
引用
收藏
页码:243 / 254
页数:12
相关论文
共 36 条
  • [21] Analysis of steel fibers pull-out. Experimental study
    Isla, Facundo
    Ruano, Gonzalo
    Luccioni, Bibiana
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2015, 100 : 183 - 193
  • [22] Influence of reinforcement ratio on tension stiffening of reinforced engineered cementitious composites
    Kang, Shao-Bo
    Tan, Kang Hai
    Zhou, Xu-Hong
    Yang, Bo
    [J]. ENGINEERING STRUCTURES, 2017, 141 : 251 - 262
  • [23] Flexural behavior of precast reinforced concrete composite members reinforced with structural nano-synthetic and steel fibers
    Lee, Su-Jin
    Won, Jong-Pil
    [J]. COMPOSITE STRUCTURES, 2014, 118 : 571 - 579
  • [24] Li VC., 2008, Concrete Construction Engineering Handbook
  • [25] Service performance of steel fiber reinforced concrete (SFRC) slabs
    McMahon, Joshua A.
    Birely, Anna C.
    [J]. ENGINEERING STRUCTURES, 2018, 168 : 58 - 68
  • [26] Tension stiffening in reinforced high performance fiber reinforced cement-based composites
    Moreno, Daniel M.
    Trono, William
    Jen, Gabriel
    Ostertag, Claudia
    Billington, Sarah L.
    [J]. CEMENT & CONCRETE COMPOSITES, 2014, 50 : 36 - 46
  • [27] Proposed classification of HPFRC composites based on their tensile response
    Naaman, A. E.
    Reinhardt, H. W.
    [J]. MATERIALS AND STRUCTURES, 2006, 39 (05) : 547 - 555
  • [28] Influence of matrix cracking and hybrid fiber reinforcement on the corrosion initiation and propagation behaviors of reinforced concrete
    Nguyen, Wilson
    Duncan, Jacob F.
    Jen, Gabriel
    Ostertag, Claudia P.
    [J]. CORROSION SCIENCE, 2018, 140 : 168 - 181
  • [29] Electrochemical polarization and impedance of reinforced concrete and hybrid fiber-reinforced concrete under cracked matrix conditions
    Nguyen, Wilson
    Duncan, Jacob F.
    Devine, Thomas M.
    Ostertag, Claudia P.
    [J]. ELECTROCHIMICA ACTA, 2018, 271 : 319 - 336
  • [30] Seismic response of a rocking bridge column using a precast hybrid fiber-reinforced concrete (HyFRC) tube
    Nguyen, Wilson
    Trono, William
    Panagiotou, Marios
    Ostertag, Claudia P.
    [J]. COMPOSITE STRUCTURES, 2017, 174 : 252 - 262