Mechanics and failure characteristics of hybrid fiber-reinforced concrete (HyFRC) composites with longitudinal steel reinforcement

被引:29
作者
Nguyen, Wilson [1 ,4 ]
Bandelt, Matthew J. [2 ]
Trono, William [1 ]
Billington, Sarah L. [3 ]
Ostertag, Claudia P. [1 ]
机构
[1] Univ Calif Berkeley, Dept Civil & Environm Engn, Berkeley, CA 94720 USA
[2] New Jersey Inst Technol, John A Reif Jr Dept Civil & Environm Engn, Newark, NJ 07102 USA
[3] Stanford Univ, Dept Civil & Environm Engn, Stanford, CA 94305 USA
[4] Wiss Janney Elstner & Associates Inc, Emeryville, CA 94608 USA
基金
美国国家科学基金会;
关键词
High-performance fiber-reinforced cementitious composites; HPFRCC; Tension stiffening; Strain localization; Strain hardening; Inelastic; Pull out; Bond-slip; Splitting crack; Reinforcement ratio; PERFORMANCE; BEHAVIOR; CRACKING; DUCTILITY; MEMBERS;
D O I
10.1016/j.engstruct.2018.12.087
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
While the properties of hybrid fiber-reinforced concrete (HyFRC) have been well-reported in the literature, the behavior of reinforced HyFRC (i.e., HyFRC with embedded steel rebar) is less understood. This paper investigates the mechanics and failure characteristics of reinforced HyFRC under direct tension. Samples with a low longitudinal steel reinforcement ratio were studied to evaluate the feasibility of reducing rebar congestion in structural applications through the use of fiber-reinforced concrete. Although reinforced HyFRC forms multiple cracking sites when loaded, rebar strain and HyFRC crack opening are generally concentrated at a single location under post-yield displacements. The onset of rebar plastic deformation and the exhaustion of fibers' bridging load capacity are coincident events at a dominant crack. For a cracked reinforced HyFRC section to strengthen, the magnitude of load resistance increase from strain hardening rebar must exceed the magnitude of load resistance decrease from fiber pull-out processes. Comparisons are made with studies reported in the literature to demonstrate how longitudinal reinforcement ratio and fiber type influence cracking behavior and ultimate strain capacity. The research presented herein has far-reaching impacts on the structural design of all types of reinforced fiber-reinforced concrete materials detailed for a ductile response under large displacements.
引用
收藏
页码:243 / 254
页数:12
相关论文
共 36 条
  • [1] Abrishami HH, 1996, ACI STRUCT J, V93, P703
  • [2] [Anonymous], ACI MAT J
  • [3] [Anonymous], 2014, ACI 318 14
  • [4] ASTM International, 2012, C39 C39M 12A COMPR S
  • [5] ASTM International, 2012, A193 A193M 12B ALL S
  • [6] ASTM International, 2009, A706 A706M 09B LOW A
  • [7] ASTM International, 2012, C150 C150M 12 PORTL
  • [8] Simulation of Deformation Capacity in Reinforced High-Performance Fiber-Reinforced Cementitious Composite Flexural Members
    Bandelt, Matthew J.
    Billington, Sarah L.
    [J]. JOURNAL OF STRUCTURAL ENGINEERING, 2018, 144 (10)
  • [9] Bond behavior of steel reinforcement in high-performance fiber-reinforced cementitious composite flexural members
    Bandelt, Matthew J.
    Billington, Sarah L.
    [J]. MATERIALS AND STRUCTURES, 2016, 49 (1-2) : 71 - 86
  • [10] Bond behavior and interface modeling of reinforced high-performance fiber-reinforced cementitious composites
    Bandelt, Matthew J.
    Frank, Timothy E.
    Lepech, Michael D.
    Billington, Sarah L.
    [J]. CEMENT & CONCRETE COMPOSITES, 2017, 83 : 188 - 201