A Novel Method for Measuring In-Shoe Navicular Drop during Gait

被引:16
作者
Kappel, Simon L. [1 ]
Rathleff, Michael S. [2 ]
Hermann, Dan [1 ]
Simonsen, Ole [2 ]
Karstoft, Henrik [1 ]
Ahrendt, Peter [1 ]
机构
[1] Aarhus Univ, Dept Engn, Signal Proc & Control Grp, DK-8200 Aarhus N, Denmark
[2] Aarhus Univ Hosp, Aalborg Hosp, Orthopaed Surg Res Unit, DK-9000 Aalborg, Denmark
关键词
capacitive strain sensor; gait analysis; foot movement; foot dynamics; Danfoss PolyPower; dielectric electro active polymer (DEAP); navicular drop; multi-video sequence analysis; TIBIAL STRESS SYNDROME; ANKLE FOOT COMPLEX; NORMAL WALKING; RISK-FACTORS; KINEMATICS; MOTION; SENSOR; STRAIN; PRONATION; TEXTILE;
D O I
10.3390/s120911697
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Analysis of foot movement is essential in the treatment and prevention of foot-related disorders. Measuring the in-shoe foot movement during everyday activities, such as sports, has the potential to become an important diagnostic tool in clinical practice. The current paper describes the development of a thin, flexible and robust capacitive strain sensor for the in-shoe measurement of the navicular drop. The navicular drop is a well-recognized measure of foot movement. The position of the strain sensor on the foot was analyzed to determine the optimal points of attachment. The sensor was evaluated against a state-of-the-art video-based system that tracks reflective markers on the bare foot. Preliminary experimental results show that the developed strain sensor is able to measure navicular drop on the bare foot with an accuracy on par with the video-based system and with a high reproducibility. Temporal comparison of video-based, barefoot and in-shoe measurements indicate that the developed sensor measures the navicular drop accurately in shoes and can be used without any discomfort for the user.
引用
收藏
页码:11697 / 11711
页数:15
相关论文
共 29 条
[1]  
Benslimane M.Y., 2010, P SOC PHOTO-OPT INS
[2]   Highly flexible capacitive strain gauge for continuous long-term blood pressure monitoring [J].
Bingger, P. ;
Zens, M. ;
Woias, P. .
BIOMEDICAL MICRODEVICES, 2012, 14 (03) :573-581
[3]   A Prospective Investigation of Biomechanical Risk Factors for Patellofemoral Pain Syndrome The Joint Undertaking to Monitor and Prevent ACL Injury (JUMP-ACL) Cohort [J].
Boling, Michelle C. ;
Padua, Darin A. ;
Marshall, Stephen W. ;
Guskiewicz, Kevin ;
Pyne, Scott ;
Beutler, Anthony .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2009, 37 (11) :2108-2116
[4]   Kinematic analysis of a multi-segment foot model for research and clinical applications: a repeatability analysis [J].
Carson, MC ;
Harrington, ME ;
Thompson, N ;
O'Connor, JJ ;
Theologis, TN .
JOURNAL OF BIOMECHANICS, 2001, 34 (10) :1299-1307
[5]   Design and development of a flexible strain sensor for textile structures based on a conductive polymer composite [J].
Cochrane, Cedric ;
Koncar, Vladan ;
Lewandowski, Maryline ;
Dufour, Claude .
SENSORS, 2007, 7 (04) :473-492
[6]   Relative movement of the navicular bone during normal walking [J].
Cornwall, MW ;
McPoil, TG .
FOOT & ANKLE INTERNATIONAL, 1999, 20 (08) :507-512
[7]  
Gray F., 1953, United States Patent
[8]   New method of studying joint kinematics from three-dimensional reconstructions of MRI data [J].
Hirsch, BE ;
Udupa, JK ;
Samarasekera, S .
JOURNAL OF THE AMERICAN PODIATRIC MEDICAL ASSOCIATION, 1996, 86 (01) :4-15
[9]  
Jensen K., 2009, PHOTOGRAMM J FINLAND, V21, P25
[10]   Rear-foot, mid-foot and fore-foot motion during the stance phase of gait [J].
Leardini, A. ;
Benedetti, M. G. ;
Berti, L. ;
Bettinelli, D. ;
Nativo, R. ;
Giannini, S. .
GAIT & POSTURE, 2007, 25 (03) :453-462