A comparison of tympanic and rectal temperatures in term Nigerian neonates

被引:22
作者
Duru, Chika O. [1 ]
Akinbami, Felix O. [1 ]
Orimadegun, Adebola E. [1 ,2 ]
机构
[1] Univ Ibadan, Coll Med, Dept Paediat, Ibadan, Nigeria
[2] Univ Ibadan, Coll Med, Inst Child Hlth, Ibadan, Nigeria
关键词
Rectal temperature; Tympanic temperature; Sensitivity; Specificity; Predictive values; Term neonates; NEWBORN-INFANTS; THERMOMETRY; CHILDREN;
D O I
10.1186/1471-2431-12-86
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background: Tympanic thermometry has come as a suitable alternative to traditional thermometry because of its safety and ease of use. However, it is still yet to gain wide acceptance in African settings due to conflicting results on its accuracy, thus rectal thermometry remains the gold standard in the newborn. The aim of this study was to compare tympanic and rectal temperatures in term Nigerian neonates. Methods: Rectal and tympanic temperatures were measured simultaneously in 300 consecutive term neonates between the ages of 37 and 42 weeks gestation using mercury-in-glass and the Infrared tympanic thermometers respectively. Paired t test, Pearson correlation coefficient and the Bland-Altman plot were used to compute data. Using rectal thermometry as gold standard, the sensitivity, specificity and predictive values of tympanic thermometry at various rectal temperature cut-offs were determined. Receiver Operating Curves (ROC) were constructed and the Areas Under the Curves (AUC) were compared. Results: The mean rectal temperature (37.34 +/- 0.55 degrees C) was significantly higher than the mean tympanic temperature (37.25 +/- 0.56 degrees C) (p < 0.001) with a mean difference of 0.09 degrees C +/- 0.24 degrees C (95% CI: 0.06, 0.12). There was a strong positive correlation between the two measurements (r = 0.9; p < 0.001). Tympanic thermometry showed sensitivities ranging from 65% to 86% and specificities of 95% to 99% at rectal temperature cut-offs of 37.5 degrees C to 38 C. The positive and negative predictive values of the tympanic temperatures at the various temperature cut-offs ranged from 82% to 93% and 80% to 98% respectively. Accuracy was noted to increase with higher temperatures as shown by the Receiver Operating Curves with the highest accuracy at the temperature cut-off of 38 C and AUC of 0.91. Conclusions: The sensitivity of tympanic thermometry was relatively low in detecting rectal temperatures despite the good correlation and agreement between them. The specificities and predictive values of tympanic temperatures in detecting rectal temperatures were high and accuracy increased with higher temperatures. Though using the tympanic route for measuring temperature in the newborn is relatively safe and non-invasive, its low sensitivity limits its use. Further studies would be required to further assess the accuracy of tympanic temperature measurements in the newborn.
引用
收藏
页数:8
相关论文
共 19 条
[1]   Tympanic thermometry in Nigerian children [J].
Akinyinka, OO ;
Omokhodion, SI ;
Olawuyi, JF ;
Olumese, PE ;
Brown, BJ .
ANNALS OF TROPICAL PAEDIATRICS, 2001, 21 (02) :169-174
[2]   Tympanic membrane temperature as a measure of core temperature [J].
Childs, C ;
Harrison, R ;
Hodkinson, C .
ARCHIVES OF DISEASE IN CHILDHOOD, 1999, 80 (03) :262-266
[3]   Infrared ear thermometry compared with rectal thermometry in children: a systematic review [J].
Craig, JV ;
Lancaster, GA ;
Taylor, S ;
Williamson, PR ;
Smyth, RL .
LANCET, 2002, 360 (9333) :603-609
[4]  
Dew Paula L, 2006, J Child Health Care, V10, P96, DOI 10.1177/1367493506062550
[5]   Fever detection in under 5 children in a tertiary health facility using the infrared tympanic thermometer in the oral mode [J].
Edelu, Benedict O. ;
Ojinnaka, Ngozi C. ;
Ikefuna, Anthony N. .
ITALIAN JOURNAL OF PEDIATRICS, 2011, 37
[6]   Thermometry in paediatric practice [J].
El-Rashdi, AS ;
Barry, W .
ARCHIVES OF DISEASE IN CHILDHOOD, 2006, 91 (04) :351-356
[7]  
JOHNSON KJ, 1991, PEDIATRICS, V87, P34
[8]  
Martin Sarah A, 2004, AACN Clin Issues, V15, P254, DOI 10.1097/00044067-200404000-00011
[9]   TEMPERATURE-MEASUREMENT IN TERM AND PRETERM NEONATES [J].
MAYFIELD, SR ;
BHATIA, J ;
NAKAMURA, KT ;
RIOS, GR ;
BELL, EF .
JOURNAL OF PEDIATRICS, 1984, 104 (02) :271-275
[10]  
MCALLISTER TA, 1986, LANCET, V1, P1262