Swept source optical coherence tomography measurement of the iris-trabecular contact (ITC) index: a new parameter for angle closure

被引:49
作者
Ho, Sue-Wei [1 ,2 ]
Baskaran, Mani [1 ,2 ,3 ]
Zheng, Ce [1 ,2 ,3 ]
Tun, Tin A. [1 ,2 ]
Perera, Shamira A. [1 ,2 ]
Narayanaswamy, Arun K. [1 ,2 ]
Friedman, David S. [4 ,5 ]
Aung, Tin [1 ,2 ,3 ]
机构
[1] Singapore Eye Res Inst, Singapore, Singapore
[2] Singapore Natl Eye Ctr, Singapore 168751, Singapore
[3] Natl Univ Singapore, Yong Loo Lin Sch Med, Singapore 117595, Singapore
[4] Dana Ctr Prevent Ophthalmol, Baltimore, MD USA
[5] Johns Hopkins Bloomberg Sch Publ Hlth, Wilmer Eye Inst, Baltimore, MD USA
关键词
Angle closure glaucoma; Swept source optical coherence tomography; Gonioscopy; Iris; Agreement; NARROW ANGLES; ANTERIOR; GLAUCOMA;
D O I
10.1007/s00417-012-2158-6
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To evaluate the inter- and intra-observer agreement of measurement of the iris-trabecular contact (ITC) index, a measure of the degree of angle closure, using swept source optical coherence tomography (SSOCT, CASIA SS-1000, Tomey Corporation, Nagoya, Japan). One randomly selected eye of 60 subjects was imaged under dark room conditions. The SSOCT 3-dimensional angle scan simultaneously obtains 128 radial scans of the anterior chamber for the entire circumference of the angle. Post-imaging analysis estimated the ITC index using in-built software. For intra-observer agreement for image grading, one examiner performed the grading twice in a masked fashion and random order after a 1-week interval. A second examiner graded images to assess inter-observer agreement for image grading. For intra-observer agreement for image acquisition, a single operator imaged patients twice. For inter-observer agreement for image acquisition, a single observer graded two sets of images acquired by two different operators on the same patient. Bland-Altman plots and 95 % limits of agreement (LOA) were reported. Study subjects were predominantly Chinese (54/60, 90 %) and female (42/60, 70 %), with a mean age of 65.5 years. The median ITC index for eyes with open angles (31/60) and closed angles was 20 % (95 % confidence interval [CI] - 13.6, 27.8) and 49 % (95%CI - 35.5, 69.2) respectively. The mean difference (95 % LOA) for intra-observer agreement for image grading and image acquisition were -0.8 % (-8.2, 6.5) and 0.6 % (-10.9, 9.7); corresponding inter- observer agreement were 0.1 % (-10, 10.1) and -0.3 % (-11.1, 10.5) respectively. The inter- and intra-observer agreement of the ITC index, as a measure of extent of angle closure using SSOCT, was good.
引用
收藏
页码:1205 / 1211
页数:7
相关论文
共 11 条
[1]   ISSUES IN THE EPIDEMIOLOGY AND POPULATION-BASED SCREENING OF PRIMARY ANGLE-CLOSURE GLAUCOMA [J].
CONGDON, N ;
WANG, F ;
TIELSCH, JM .
SURVEY OF OPHTHALMOLOGY, 1992, 36 (06) :411-423
[2]   Glaucoma in China: how big is the problem? [J].
Foster, PJ ;
Johnson, GJ .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2001, 85 (11) :1277-1282
[3]   Novel approach for anterior chamber angle analysis - Anterior chamber angle detection with edge measurement and identification algorithm (ACADEMIA) [J].
Leung, Christopher Kai-shun ;
Yung, Wing-ho ;
Yiu, Cedric Ka-fai ;
Lam, Sze-wing ;
Leung, Dexter Yu-lung ;
Tse, Raymond Kwok-kay ;
Tham, Clement Chi-yung ;
Chan, Wai-man ;
Lam, Dennis Shun-chiu .
ARCHIVES OF OPHTHALMOLOGY, 2006, 124 (10) :1395-1401
[4]   Anterior Chamber Angle Imaging with Swept-Source Optical Coherence Tomography: An Investigation on Variability of Angle Measurement [J].
Liu, Shu ;
Yu, Marco ;
Ye, Cong ;
Lam, Dennis S. C. ;
Leung, Christopher Kai-shun .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (12) :8598-8603
[5]  
Narayanaswamy A, 2010, ARCH OPHTHALMOL-CHIC, V128, P1321, DOI 10.1001/archophthalmol.2010.231
[6]   Anterior chamber measurements using Pentacam rotating Scheimpflug camera [J].
Rabsilber, TM ;
Khoramnia, R ;
Auffarth, GU .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (03) :456-459
[7]  
Sasidharan R, 2008, S E ASIA GLAUCOMA IN
[8]   High-Definition Optical Coherence Tomography Imaging of the Iridocorneal Angle of the Eye [J].
Wong, Hon-Tym ;
Lim, Marcus C. ;
Sakata, Lisandro M. ;
Aung, Han T. ;
Amerasinghe, Nishani ;
Friedman, David S. ;
Aung, Tin .
ARCHIVES OF OPHTHALMOLOGY, 2009, 127 (03) :256-260
[9]   Association of Narrow Angles With Anterior Chamber Area and Volume Measured With Anterior-Segment Optical Coherence Tomography [J].
Wu, Ren-Yi ;
Nongpiur, Monisha E. ;
He, Ming-Guang ;
Sakata, Lisandro M. ;
Friedman, David S. ;
Chan, Yiong-Huak ;
Lavanya, Raghavan ;
Wong, Tien-Yin ;
Aung, Tin .
ARCHIVES OF OPHTHALMOLOGY, 2011, 129 (05) :569-574
[10]   Anterior segment imaging: Fourier-domain optical coherence tomography versus time-domain optical coherence tomography [J].
Wylegala, Edward ;
Teper, Slawornir ;
Nowinska, Anna K. ;
Milka, Michal ;
Dobrowolski, Dariusz .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (08) :1410-1414