Laser scribed graphene: A novel platform for highly sensitive detection of electroactive biomolecules

被引:56
作者
Ghanam, Abdelghani [1 ]
Lahcen, Abdellatif Ait [2 ]
Beduk, Tutku [2 ]
Alshareef, Husam N. [3 ]
Amine, Aziz [1 ]
Salama, Khaled Nabil [2 ]
机构
[1] Hassan II Univ Casablanca, Fac Sci & Tech, Lab Proc Engn & Environm, Chem Anal & Biosensors Grp, BP 146, Mohammadia, Morocco
[2] King Abdullah Univ Sci & Technol KAUST, Comp Elect & Math Sci & Engn Div, Adv Membranes & Porous Mat Ctr AMPMC, Sensors Lab,Elect Engn Program, Thuwal 239556900, Saudi Arabia
[3] King Abdullah Univ Sci & Technol KAUST, Mat Sci & Engn, Phys Sci & Engn Div, Thuwal 239556900, Saudi Arabia
关键词
Laser-scribed graphene; Biosensor platform; Biomolecules; Phenolic compounds; Paracetamol; GLASSY-CARBON ELECTRODE; SIMULTANEOUS VOLTAMMETRIC DETERMINATION; DOPED DIAMOND ELECTRODE; ELECTROCHEMICAL SENSOR; ELECTROANALYTICAL DETERMINATION; ASCORBIC-ACID; PARACETAMOL; ACETAMINOPHEN; EPINEPHRINE; PERFORMANCE;
D O I
10.1016/j.bios.2020.112509
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Laser-scribed graphene electrodes (LSGEs) have recently shown a potential for the development of electrochemical biosensors thanks to their electronic properties, porous structures, and large surface area that can support the charge transfer. In this paper, the authors present a comparative study of the electrochemical performances of LSGEs with the conventional screen-printed carbon electrodes (SPCEs) toward the detection of most commonly used phenolic compounds and biomolecules. Cyclic voltammetry measurements showed a significant enhancement in the electron transfer rate of all tested electmactive species at LSGEs compared to conventional SPCE. We have suggested, for the first time, a mechanistic study for catecholamine redox reactions at LSGE as the electron transfer-chemical reaction-electron transfer mechanism. Moreover, the excellent performances of LSGE were observed in terms of the electrocatalytic detection of paracetamol (PCM). Therefore, the second part of this study compared the analytical performances of LSGE and SPCE with respect to the detection of PCM. The LSGE allows a fast and reversible system for PCM with a low Delta E-p of 88 mV while the SPCE exhibits a quasi-reversible system with a higher Delta E-p of 384 mV. The LSGE demonstrated a PCM linear range of concentration between 0.1 mu M and 10 mu M, with a detection limit of 31 nM. In addition, the LSGE showed a successful applicability with good selectivity and sensitivity for PCM determination in real samples of pharmaceutical tablets. Hence, LSGEs could be an excellent platform for simple and low-cost electrochemical biosensor applications.
引用
收藏
页数:10
相关论文
共 73 条
  • [1] Impact of Fermentation on the Phenolic Compounds and Antioxidant Activity of Whole Cereal Grains: A Mini Review
    Adebo, Oluwafemi Ayodeji
    Medina-Meza, Ilce Gabriela
    [J]. MOLECULES, 2020, 25 (04):
  • [2] Sensitive Detection of Acetaminophen with Graphene-Based Electrochemical Sensor
    Adhikari, Bal-Ram
    Govindhan, Maduraiveeran
    Chen, Aicheng
    [J]. ELECTROCHIMICA ACTA, 2015, 162 : 198 - 204
  • [3] Deposition of nanomaterials: A crucial step in biosensor fabrication
    Ahmad, Rafiq
    Wolfbeis, Otto S.
    Hahn, Yoon-Bong
    Alshareef, Husam N.
    Torsi, Luisa
    Salama, Khaled N.
    [J]. MATERIALS TODAY COMMUNICATIONS, 2018, 17 : 289 - 321
  • [4] Mini-review: Recent Advances in Electrochemical Determination of Sulfonamides
    Ait Lahcen, Abdellatif
    Amine, Aziz
    [J]. ANALYTICAL LETTERS, 2018, 51 (03) : 424 - 441
  • [5] Amine A.M.H., 2019, ENCY ANAL SCI, P85
  • [6] Voltammetric determination of epinephrine and xanthine based on sodium dodecyl sulphate assisted tungsten trioxide nanoparticles
    Anithaa, A. C.
    Asokan, K.
    Sekar, C.
    [J]. ELECTROCHIMICA ACTA, 2017, 237 : 44 - 53
  • [7] Amperometric inhibition biosensors based on horseradish peroxidase and gold sononanoparticles immobilized onto different electrodes for cyanide measurements
    Attar, Aisha
    Cubillana-Aguilera, Laura
    Naranjo-Rodriguez, Ignacio
    Hidalgo-Hidalgo de Cisneros, Jose Luis
    Maria Palacios-Santander, Jose
    Amine, Aziz
    [J]. BIOELECTROCHEMISTRY, 2015, 101 : 84 - 91
  • [8] Nanomaterial-based electrochemical sensors for the detection of neurochemicals in biological matrices
    Azzouz, Abdelmonaim
    Goud, K. Yugender
    Raza, Nadeem
    Ballesteros, Evaristo
    Lee, Sung-Eun
    Hong, Jongki
    Deep, Akash
    Kim, Ki-Hyun
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2019, 110 : 15 - 34
  • [9] Application of Single-use Electrode Based on Nano-clay and MWCNT for Simultaneous Determination of Acetaminophen, Ascorbic Acid and Acetylsalicylic Acid in Pharmaceutical Dosage
    Bayraktepe, Dilek Eskikoy
    Yazan, Zehra
    [J]. ELECTROANALYSIS, 2020, 32 (06) : 1263 - 1272
  • [10] Sensitive and cost effective disposable composite electrode based on graphite, nano-smectite and multiwall carbon nanotubes for the simultaneous trace level detection of ascorbic acid and acetylsalicylic acid in pharmaceuticals
    Bayraktepe, Dilek Eskikoy
    Yazan, Zehra
    Onal, Muserref
    [J]. TALANTA, 2019, 203 : 131 - 139