Single Walled Carbon Nanotubes/polypyrrole-GOx composite films to modify gold microelectrodes for glucose biosensors: Study of the extended linearity

被引:43
作者
Valentini, F. [1 ]
Galache Fernandez, L. [2 ]
Tamburri, E. [1 ]
Palleschi, G. [1 ]
机构
[1] Univ Roma Tor Vergata, Dipartimento Chim, I-00133 Rome, Italy
[2] Univ A Coruna, La Coruna, Spain
关键词
EPD deposition; Single-Wall Carbon Nanotubes; SWCNT/PPy nanocomposites; Permeability; Perm-selectivity; Microelectrodes; POLYPYRROLE; OXIDASE;
D O I
10.1016/j.bios.2012.11.019
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A glucose biosensor was assembled using gold microelectrodes (diameter of 250 mu m) coated by Single-Walled Carbon Nanotubes (SWCNTs), via the Electrophoresis Deposition Process (EPD). This nanostructured platform was successfully used to deposit the poly(pyrrole)/glucose oxidase film (PPy/GOx). The most important result of this biosensors was the wide linear range of concentration, ranging from 4 to 100 mM (covering the hypo- and hyper-glycemia range, useful in diabetes). This extended linearity offered the possibility to measure glucose from 0.560 to 12.0 mM, with a detection limit of 50 mu M (useful for hypo-glycemia disease). (c) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:75 / 78
页数:4
相关论文
共 13 条
[1]   ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY [J].
CLARK, LC ;
LYONS, C .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1962, 102 (01) :29-&
[2]   OPTIMIZATION OF A POLYPYRROLE GLUCOSE-OXIDASE BIOSENSOR [J].
FORTIER, G ;
BRASSARD, E ;
BELANGER, D .
BIOSENSORS & BIOELECTRONICS, 1990, 5 (06) :473-490
[3]   RECENT ADVANCES IN AMPEROMETRIC GLUCOSE BIOSENSORS FOR IN-VIVO MONITORING [J].
JAFFARI, SA ;
TURNER, APF .
PHYSIOLOGICAL MEASUREMENT, 1995, 16 (01) :1-15
[4]  
Laviron E.J., 1979, ELECTROANALYTICAL CH, V100, P263
[5]   GLUCOSE ELECTROCHEMICAL PROBE WITH EXTENDED LINEARITY FOR WHOLE-BLOOD [J].
MASCINI, M ;
SELLERI, S ;
RIVIELLO, M .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1989, 7 (12) :1507-1512
[6]   CONTINUOUS-FLOW SENSOR STRATEGY COMPRISING A ROTATING BIOREACTOR AND A STATIONARY RING AMPEROMETRIC DETECTOR [J].
MATSUMOTO, K ;
BAEZA, JJB ;
MOTTOLA, HA .
ANALYTICAL CHEMISTRY, 1993, 65 (05) :636-639
[7]  
Moscone D., 1993, RUSIAN J ELECTROCHEM, V29, P1522
[8]  
Pesce A.J., 1987, METHODS CLIN CHEM
[9]   Simultaneous determination of film permeability to H2O2 and substrate surface area coverage of overoxidized polypyrrole [J].
Reyes De Corcuera, JI ;
Cavalieri, RP ;
Powers, JR .
SYNTHETIC METALS, 2004, 142 (1-3) :71-79
[10]  
Saito R., 1998, Physical Properties of Carbon Nanotubes