Dynamic regulation reliability of a pumped-storage power generating system: Effects of wind power injection

被引:35
作者
Xu, Beibei [1 ,2 ]
Li, Huanhuan [1 ,2 ]
Campana, Pietro Elia [3 ]
Hredzak, Branislav [4 ]
Chen, Diyi [1 ,2 ]
机构
[1] Northwest A&F Univ, Key Lab Agr Soil & Water Engn Arid & Semiarid Are, Minist Educ, Yangling 712100, Shaanxi, Peoples R China
[2] Northwest A&F Univ, Inst Water Resources & Hydropower Res, Yangling 712100, Shaanxi, Peoples R China
[3] Malardalen Univ, Sch Sustainable Dev Soc & Technol, SE-72123 Vasteras, Sweden
[4] Univ New South Wales, Sch Elect Engn & Telecommun, Sydney, NSW 2052, Australia
关键词
Regulation reliability; Hydro-wind hybrid power system; Coupling fluctuations; Multiple time-scale effect; TURBINE GOVERNING SYSTEM; HYDRO-ENERGY-STORAGE; STABILITY ANALYSIS; SOLAR; OPERATION; PLANTS; OPTIMIZATION; PERFORMANCE; DESIGN; MODEL;
D O I
10.1016/j.enconman.2020.113226
中图分类号
O414.1 [热力学];
学科分类号
摘要
Multi-energy integrated sources are increasingly being used as the bundling-sale for electric systems. Estimating the power supply reliability and regulation performance of the fixed-speed Pumped-Storage Generation Systems (PSGSs) in suppressing power fluctuations of intermittent energy is essential to the operational safety and re-liability of a system. However, the regulation process relates to the coupling fluctuations of hydraulic -me-chanical-electrical factors, leading to a multiple time-scale effect to the whole hybrid power system. This makes the PSGS's power response lagging behind the wind power fluctuation and further impacts the power supply reliability of the hybrid power system. To enable the analysis, a numerical model which describes operating states of the presented integrated system, including wind energy and PSGS, is developed in MATLAB/Simulink. Then, ten wind scenarios are selected to study complementation and regulation ability of the PSGS based on a framework of evaluation indicators. The results show that longer power response delay and larger guide vane distance opening result in weaker complementary response of PSGS to wind disturbances. It is also shown that the PSGS provides good complementary capability at lower random wind standard deviation (0.5 vs 1.5), larger wind speed mean value (15 m/s vs 13 m/s) and lower wind speed deviation (5 m/s vs 12 m/s). Furthermore, an unexpected regulation behavior is demonstrated: fast settling and peak times coincide with large variation in overshoot, undershoot and peak value of the power response. This presents a challenge in assessing performance of the integrated generation system. The proposed evaluation method and presented results are important steps to increasing the national power grid capability to accept high integration of multiple energy sources.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Dynamic analysis of island systems with wind-pumped-storage hybrid power stations
    Papaefthymiou, Stefanos V.
    Lakiotis, Vasileios G.
    Margaris, Ioannis D.
    Papathanassiou, Stavros A.
    RENEWABLE ENERGY, 2015, 74 : 544 - 554
  • [42] Dynamic analysis of variable-speed pumped storage plants for mitigating effects of excess wind power generation
    Deng, Yuwen
    Wang, Pengfei
    Morabito, Alessandro
    Feng, Wenfeng
    Mahmud, Apel
    Chen, Diyi
    Hendrick, Patrick
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2022, 135
  • [43] Numerical and experimental assessment of the water discharge segment in a pumped-storage power station
    Zhu, Hongtao
    Gao, Xueping
    Liu, Yinzhu
    Liu, Shuai
    ENERGY, 2023, 265
  • [44] A new setting criterion of tailrace surge chambers for pumped-storage power plants
    Huang, Wei
    Yang, Kailin
    Ma, Jiming
    Xu, Yaowu
    Guo, Xinlei
    Wang, Jue
    RENEWABLE ENERGY, 2018, 116 : 194 - 201
  • [45] Multitime Scale Coordinated Scheduling for the Combined System of Wind Power, Photovoltaic, Thermal Generator, Hydro Pumped Storage, and Batteries
    Xia, Shiwei
    Ding, Zhaohao
    Du, Ting
    Zhang, Dongying
    Shahidehpour, Mohammad
    Ding, Tao
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2020, 56 (03) : 2227 - 2237
  • [46] Reliability assessment of a wind-power system with integrated energy storage
    Bhuiyan, F. A.
    Yazdani, A.
    IET RENEWABLE POWER GENERATION, 2010, 4 (03) : 211 - 220
  • [47] Energy Storage System Sizing Based on a Reliability Assessment of Power Systems Integrated with Wind Power
    Shi, Nian
    Luo, Yi
    SUSTAINABILITY, 2017, 9 (03):
  • [48] Cooperation of Wind Power and Battery Storage to Provide Frequency Regulation in Power Markets
    He, Guannan
    Chen, Qixin
    Kang, Chongqing
    Xia, Qing
    Poolla, Kameshwar
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2017, 32 (05) : 3559 - 3568
  • [49] Day-Ahead Probabilistic Model for Scheduling the Operation of a Wind Pumped-Storage Hybrid Power Station: Overcoming Forecasting Errors to Ensure Reliability of Supply to the Grid
    Jurasz, Jakub
    Kies, Alexander
    SUSTAINABILITY, 2018, 10 (06)
  • [50] Multi-objective co-optimization of the guide vane closure law and rotor inertia in pumped-storage power system
    Fu, Xiaolong
    Li, Deyou
    Wang, Hongjie
    Wei, Xianzhu
    JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2022, 14 (04)