Dynamic regulation reliability of a pumped-storage power generating system: Effects of wind power injection

被引:35
|
作者
Xu, Beibei [1 ,2 ]
Li, Huanhuan [1 ,2 ]
Campana, Pietro Elia [3 ]
Hredzak, Branislav [4 ]
Chen, Diyi [1 ,2 ]
机构
[1] Northwest A&F Univ, Key Lab Agr Soil & Water Engn Arid & Semiarid Are, Minist Educ, Yangling 712100, Shaanxi, Peoples R China
[2] Northwest A&F Univ, Inst Water Resources & Hydropower Res, Yangling 712100, Shaanxi, Peoples R China
[3] Malardalen Univ, Sch Sustainable Dev Soc & Technol, SE-72123 Vasteras, Sweden
[4] Univ New South Wales, Sch Elect Engn & Telecommun, Sydney, NSW 2052, Australia
关键词
Regulation reliability; Hydro-wind hybrid power system; Coupling fluctuations; Multiple time-scale effect; TURBINE GOVERNING SYSTEM; HYDRO-ENERGY-STORAGE; STABILITY ANALYSIS; SOLAR; OPERATION; PLANTS; OPTIMIZATION; PERFORMANCE; DESIGN; MODEL;
D O I
10.1016/j.enconman.2020.113226
中图分类号
O414.1 [热力学];
学科分类号
摘要
Multi-energy integrated sources are increasingly being used as the bundling-sale for electric systems. Estimating the power supply reliability and regulation performance of the fixed-speed Pumped-Storage Generation Systems (PSGSs) in suppressing power fluctuations of intermittent energy is essential to the operational safety and re-liability of a system. However, the regulation process relates to the coupling fluctuations of hydraulic -me-chanical-electrical factors, leading to a multiple time-scale effect to the whole hybrid power system. This makes the PSGS's power response lagging behind the wind power fluctuation and further impacts the power supply reliability of the hybrid power system. To enable the analysis, a numerical model which describes operating states of the presented integrated system, including wind energy and PSGS, is developed in MATLAB/Simulink. Then, ten wind scenarios are selected to study complementation and regulation ability of the PSGS based on a framework of evaluation indicators. The results show that longer power response delay and larger guide vane distance opening result in weaker complementary response of PSGS to wind disturbances. It is also shown that the PSGS provides good complementary capability at lower random wind standard deviation (0.5 vs 1.5), larger wind speed mean value (15 m/s vs 13 m/s) and lower wind speed deviation (5 m/s vs 12 m/s). Furthermore, an unexpected regulation behavior is demonstrated: fast settling and peak times coincide with large variation in overshoot, undershoot and peak value of the power response. This presents a challenge in assessing performance of the integrated generation system. The proposed evaluation method and presented results are important steps to increasing the national power grid capability to accept high integration of multiple energy sources.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Stochastic optimal scheduling of wind power and pumped-storage hydropower complementary systems with multiple uncertainties
    Lu, Na
    Su, Chengguo
    Guo, Chaoyu
    Wang, Peilin
    Wu, Huijun
    Sui, Quan
    JOURNAL OF ENERGY STORAGE, 2024, 78
  • [2] Dynamic modeling and favorable speed command of variable-speed pumped-storage unit during power regulation
    Huang, Yifan
    Yang, Weijia
    Zhao, Zhigao
    Han, Wenfu
    Li, Yulan
    Yang, Jiandong
    RENEWABLE ENERGY, 2023, 206 : 769 - 783
  • [3] Modeling and Optimization of Hybrid Wind/PV pumped-storage Power System
    Ren Yan
    Zheng Yuan
    Li Yanpin
    Huang Jianjun
    Zhang Dun
    MEASURING TECHNOLOGY AND MECHATRONICS AUTOMATION, PTS 1 AND 2, 2011, 48-49 : 693 - +
  • [4] Intelligent optimization of hybrid wind/PV/pumped-storage power system
    Ren, Yan
    Zheng, Yuan
    Li, Chong
    Zhou, Bing
    Mao, Zhihao
    RENEWABLE AND SUSTAINABLE ENERGY II, PTS 1-4, 2012, 512-515 : 719 - +
  • [5] Exploring the Regulation Reliability of a Pumped Storage Power Plant in a Wind-Solar Hybrid Power Generation System
    Xu, Beibei
    Zhang, Jingjing
    Egusquiza, Monica
    Zhang, Junzhi
    Chen, Diyi
    Egusquiza, Eduard
    WATER, 2021, 13 (18)
  • [6] Dynamic safety assessment of a nonlinear pumped-storage generating system in a transient process
    Li, Huanhuan
    Chen, Diyi
    Arzaghi, Ehsan
    Abbassi, Rouzbeh
    Kilicman, Adem
    Caraballo, Tomas
    Patelli, Edoardo
    Gao, Xiang
    Xu, Beibei
    COMMUNICATIONS IN NONLINEAR SCIENCE AND NUMERICAL SIMULATION, 2019, 67 : 192 - 202
  • [7] Leningrad pumped-storage power plant
    Mishin N.N.
    Mishin, N.N., 1600, Springer Science and Business Media, LLC (46): : 377 - 379
  • [8] Cross-regional integrated transmission of wind power and pumped-storage hydropower considering the peak shaving demands of multiple power grids
    Yuan, Wenlin
    Xin, Wenpeng
    Su, Chengguo
    Cheng, Chuntian
    Yan, Denghua
    Wu, Zening
    RENEWABLE ENERGY, 2022, 190 : 1112 - 1126
  • [9] Dynamic analysis of a pumped-storage hydropower plant with random power load
    Zhang, Hao
    Chen, Diyi
    Xu, Beibei
    Patelli, Edoardo
    Tolo, Silvia
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2018, 100 : 524 - 533
  • [10] Stochastic economic dispatch of power system with multiple wind farms and pumped-storage hydro stations using approximate dynamic programming
    Lin, Shunjiang
    Fan, Guansheng
    Jian, Ganyang
    Liu, Mingbo
    IET RENEWABLE POWER GENERATION, 2020, 14 (13) : 2507 - 2516