A Randomized Comparison Simulating Face to Face Endotracheal Intubation of Pentax Airway Scope, C-MAC Video Laryngoscope, Glidescope Video Laryngoscope, and Macintosh Laryngoscope

被引:6
作者
Choi, Hyun Young [1 ]
Oh, Young Min [2 ]
Kang, Gu Hyun [1 ]
Kang, Hyunggoo [3 ]
Jang, Yong Soo [1 ]
Kim, Wonhee [1 ]
Kim, Euichung [4 ]
Cho, Young Soon [5 ]
Choi, Hyukjoong [3 ]
Kim, Hyunjong [6 ]
Kim, Gyoung Yong [7 ]
机构
[1] Hallym Univ, Kangnam Sacred Heart Hosp, Coll Med, Dept Emergency Med, Seoul 150950, South Korea
[2] Catholic Univ Korea, Uijeongbu St Marys Hosp, Coll Med, Dept Emergency Med, Uijongbu 480717, South Korea
[3] Hanyang Univ, Coll Med, Dept Emergency Med, Seoul 133791, South Korea
[4] CHA Univ, Sch Med, Dept Emergency Med, Songnam 463712, Gyeonggi Do, South Korea
[5] Soonchunhyang Univ, Bucheon Hosp, Dept Emergency Med, Bucheon 420767, South Korea
[6] Inje Univ, Ilsan Paik Hosp, Dept Emergency Med, Ilsan 411706, South Korea
[7] Gyeonggi Fire Serv Acad, Yongin 449882, South Korea
关键词
TRACHEAL INTUBATION; MANAGEMENT;
D O I
10.1155/2015/961782
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Objectives. Early airway management is very important for severely ill patients. This study aimed to investigate the efficacy of face to face intubation in four different types of laryngoscopes (Macintosh laryngoscope, Pentax airway scope (AWS), Glidescope video laryngoscope (GVL), and C-MAC video laryngoscope (C-MAC)). Method. Ninety-five nurses and emergency medical technicians were trained to use the AWS, C-MAC, GVL and Macintosh laryngoscope with standard airway trainer manikin and face to face intubation. We compared VCET (vocal cord exposure time), tube pass time, 1st ventilation time, VCET to tube pass time, tube pass time to 1st ventilation time, and POGO (percentage of glottis opening) score. In addition, we compared success rate according to the number of attempts and complications. Result. VCET was similar among all laryngoscopes and POGO score was higher in AWS. AWS and Macintosh blade were faster than GVL and C-MAC in total intubation time. Face to face intubation success rate was lower in GVL than other laryngoscopes. Conclusion. AWS and Macintosh were favorable laryngoscopes in face to face intubation. GVL had disadvantage performing face to face intubation.
引用
收藏
页数:7
相关论文
共 20 条
[1]   Prehospital versus Emergency Room Intubation of Trauma Patients in Qatar: A-2-year Observational Study [J].
Al-Thani, Hassan ;
El-Menyar, Ayman ;
Latifi, Rifat .
NORTH AMERICAN JOURNAL OF MEDICAL SCIENCES, 2014, 6 (01) :12-18
[2]   Simulating face-to-face tracheal intubation of a trapped patient: a randomized comparison of the LMA Fastrach™, the GlideScope™, and the Airtraq™ laryngoscope [J].
Amathieu, R. ;
Sudrial, J. ;
Abdi, W. ;
Luis, D. ;
Hahouache, H. ;
Combes, X. ;
Dhonneur, G. .
BRITISH JOURNAL OF ANAESTHESIA, 2012, 108 (01) :140-145
[3]  
[Anonymous], CRIT CARE RES PRACT
[4]   Comparative analysis of airway scope and Macintosh laryngoscope for intubation primarily for cardiac arrest in prehospital setting [J].
Arima, Takahiro ;
Nagata, Osamu ;
Miura, Takeshi ;
Ikeda, Katsuki ;
Mizushima, Tomoya ;
Takahashi, Azusa ;
Sakaida, Koji .
AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2014, 32 (01) :40-43
[5]   Tracheal intubation with restricted access: a randomised comparison of the Pentax-Airway Scope and Macintosh laryngoscope in a manikin [J].
Asai, T. .
ANAESTHESIA, 2009, 64 (10) :1114-1117
[6]  
Breedveld P, 2001, MINIM INVASIV THER, V10, P155
[7]   COMPARISON OF SUCCESS RATES BETWEEN TWO VIDEO LARYNGOSCOPE SYSTEMS USED IN A PREHOSPITAL CLINICAL TRIAL [J].
Burnett, Aaron M. ;
Frascone, Ralph J. ;
Wewerka, Sandi S. ;
Kealey, Samantha E. ;
Evens, Zabrina N. ;
Griffith, Kent R. ;
Salzman, Joshua G. .
PREHOSPITAL EMERGENCY CARE, 2014, 18 (02) :231-238
[8]   Intubation by paramedics using the ILMA or AirTraq, KingVision, and Macintosh laryngoscopes in vehicle-entrapped patients: a manikin study [J].
Gaszynska, Ewelina ;
Samsel, Piotr ;
Stankiewicz-Rudnicki, Michal ;
Wieczorek, Andrzej ;
Gaszynski, Tomasz .
EUROPEAN JOURNAL OF EMERGENCY MEDICINE, 2014, 21 (01) :61-64
[9]   Use of the Airtraq® device for airway management in the prehospital setting - a retrospective study [J].
Gellerfors, Mikael ;
Larsson, Agneta ;
Svensen, Christer H. ;
Gryth, Dan .
SCANDINAVIAN JOURNAL OF TRAUMA RESUSCITATION & EMERGENCY MEDICINE, 2014, 22
[10]  
Kilicaslan Alper, 2014, Rev. Bras. Anestesiol., V64, P62, DOI [10.1016/j.bjane.2013.03.001, 10.1016/j.bjan.2013.03.001]