Impact of Drug-Eluting Stents on Distal Vessels

被引:7
作者
Wakabayashi, Kohei [1 ]
Mintz, Gary S. [2 ,3 ]
Weissman, Neil J. [1 ]
Stone, Gregg W. [2 ,3 ]
Ellis, Stephen G. [4 ]
Grube, Eberhard
Ormiston, John A. [5 ]
Turco, Mark A. [6 ]
Pakala, Rajbabu [1 ]
Xue, Zhenyi [1 ]
Desale, Sameer [1 ]
Laynez-Carnicero, Ana [1 ]
Romaguera, Rafael [1 ]
Sardi, Gabriel [1 ]
Pichard, Augusto D. [1 ]
Waksman, Ron [1 ]
机构
[1] Washington Hosp Ctr, Washington, DC 20010 USA
[2] Columbia Univ, Med Ctr, New York, NY USA
[3] Cardiovasc Res Fdn, New York, NY USA
[4] Cleveland Clin, Cleveland, OH 44106 USA
[5] N Shore Hosp, Auckland, New Zealand
[6] Washington Adventist Hosp, Takoma Pk, MD USA
关键词
distal vessel; drug-eluting stent; vessel response; INTRAVASCULAR ULTRASOUND ANALYSIS; CORONARY ENDOTHELIAL DYSFUNCTION; BARE-METAL STENT; SHEAR-STRESS; ARTERY-DISEASE; LOCAL-DELIVERY; FOLLOW-UP; TAXUS-IV; SIROLIMUS; PACLITAXEL;
D O I
10.1161/CIRCINTERVENTIONS.111.965780
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Previous studies have not addressed vessel response >5 mm distal to the stent edge. Therefore, we investigated the impact of paclitaxel-eluting stents (PES) versus bare metal stents (BMS) on distal vessels in the serial intravascular ultrasound substudies of TAXUS IV, V, and VI. Methods and Results-TAXUS IV, V, and VI were double-blind, randomized, multicenter, controlled trials comparing PES with BMS. In their intravascular ultrasound substudies, 103 patients (54 BMS, 49 PES) had intravascular ultrasound data >= 10 mm distal to the stent both postprocedure and at 9 months follow-up. Baseline characteristics were similar between the 2 groups. Multilevel modeling was used to account for the variation between patients and within patients among distal segments. Effect of stent type, time, and their interaction was tested using a mixed effect model controlling for distal segments. Postprocedure lumen and vessel were not significantly different between PES versus BMS; however, lumen (P=0.006) and vessel (P=0.0001) were significantly reduced for BMS at 9-month follow-up but not for PES. Conversely, there was a significant plaque increase from postprocedure to 9-month follow-up for PES (P=0.0008) but not for BMS. These vessel responses were statistically consistent among 0- to 5-mm versus 5- to 10-mm versus 10- to 15-mm segments distal to the stent in both groups. Conclusions-PES use was associated with plaque increase from baseline to 9-month follow-up >5 mm distal to the stent along with positive remodeling, whereas BMS use was associated with negative remodeling and no plaque increase. These vessel responses were consistent in 5- mm long subsegments: 0 to 5 mm versus 5 to 10 mm versus 10 to 15 mm distal to the stent. Clinical Trial Registration-URL: http://www.clinicaltrial.gov. Unique identifiers: TAXUS IV-NCT00292474; TAXUS V-NCT00301522; TAXUS VI-NCT00297804. (Circ Cardiovasc Interv. 2012;5:211-219.)
引用
收藏
页码:211 / 219
页数:9
相关论文
共 48 条
[1]   Impact of sirolimus-eluting stent implantation compared to bare-metal stent implantation for acute myocardial infarction on coronary plaque composition at nine months follow-up: a Virtual Histology intravascular ultrasound analysis. Results from the Leiden MISSION! intervention study [J].
Atary, Jael Z. ;
Bergheanu, Sandrin C. ;
van der Hoeven, Bas L. ;
Atsma, Douwe E. ;
Bootsma, Marianne ;
van der Kley, Frank ;
Zeppenfeld, Katja ;
Jukema, J. Wouter ;
Schalij, Martin J. .
EUROINTERVENTION, 2009, 5 (05) :565-572
[2]   Morphological predictors of arterial remodeling in coronary atherosclerosis [J].
Burke, AP ;
Kolodgie, FD ;
Farb, A ;
Weber, D ;
Virmani, R .
CIRCULATION, 2002, 105 (03) :297-303
[3]  
Cater GM, 2010, CIRCULATION, V122
[4]   Clinical efficacy of polymer-based paclitaxel-eluting stents in the treatment of complex, long coronary artery lesions from a multicenter, randomized trial - Support for the use of drug-eluting Stents in contemporary clinical practice [J].
Dawkins, KD ;
Grube, E ;
Guagliumi, G ;
Banning, AP ;
Zmudka, K ;
Colombo, A ;
Thuesen, L ;
Hauptman, K ;
Marco, J ;
Wijns, W ;
Popma, JJ ;
Koglin, J ;
Russell, ME .
CIRCULATION, 2005, 112 (21) :3306-3313
[5]   Significance of automated stenosis detection during quantitative angiography - Insights gained from intracoronary ultrasound imaging [J].
Escaned, J ;
Baptista, J ;
DiMario, C ;
Haase, J ;
Ozaki, Y ;
Linker, DT ;
deFeyter, PJ ;
Roelandt, JRTC ;
Serruys, PW .
CIRCULATION, 1996, 94 (05) :966-972
[6]   Pathological analysis of local delivery of paclitaxel via a polymer-coated stent [J].
Farb, A ;
Heller, PF ;
Shroff, S ;
Cheng, L ;
Kolodgie, FD ;
Carter, AJ ;
Scott, DS ;
Froehlich, J ;
Virmani, R .
CIRCULATION, 2001, 104 (04) :473-479
[7]   Pathological correlates of late drug-eluting stent thrombosis - Strut coverage as a marker of endothelialization [J].
Finn, Aloke V. ;
Joner, Michael ;
Nakazawa, Gaku ;
Kolodgie, Frank ;
Newell, John ;
John, Mike C. ;
Gold, Herman K. ;
Virmani, Renu .
CIRCULATION, 2007, 115 (18) :2435-2441
[8]   Differential response of delayed healing and persistent inflammation at sites of overlapping sirolimus- or paclitaxel-eluting stents [J].
Finn, AV ;
Kolodgie, FD ;
Harnek, J ;
Guerrero, LJ ;
Acampado, E ;
Tefera, K ;
Skorija, K ;
Weber, DK ;
Gold, HK ;
Virmani, R .
CIRCULATION, 2005, 112 (02) :270-278
[9]   Impaired endothelial vasomotor function after sirolimus-eluting stent implantation [J].
Fuke, Soichiro ;
Maekawa, Kiyoaki ;
Kawamoto, Kenji ;
Saito, Hironori ;
Sato, Tetsuya ;
Hioka, Toru ;
Ohe, Tohru .
CIRCULATION JOURNAL, 2007, 71 (02) :220-225
[10]   COMPENSATORY ENLARGEMENT OF HUMAN ATHEROSCLEROTIC CORONARY-ARTERIES [J].
GLAGOV, S ;
WEISENBERG, E ;
ZARINS, CK ;
STANKUNAVICIUS, R ;
KOLETTIS, GJ .
NEW ENGLAND JOURNAL OF MEDICINE, 1987, 316 (22) :1371-1375