Electrochemical determination of olmesartan medoxomil using hydrothermally prepared nanoparticles composed SnO2-Co3O4 nanocubes in tablet dosage forms

被引:73
作者
Rahman, Mohammed M. [1 ,2 ]
Khan, Sher Bahadar [1 ,2 ]
Faisal, M. [3 ,4 ]
Rub, Malik Abdul [1 ,2 ]
Al-Youbi, Abdulrahman O. [2 ]
Asiri, Abdullah M. [1 ,2 ]
机构
[1] King Abdulaziz Univ, Fac Sci, CEAMR, Jeddah 21589, Saudi Arabia
[2] King Abdulaziz Univ, Fac Sci, Dept Chem, Jeddah 21589, Saudi Arabia
[3] Najran Univ, Fac Sci & Arts, Dept Chem, Najran 11001, Saudi Arabia
[4] Najran Univ, Fac Sci & Arts, Adv Mat & Nano Res Ctr, Najran 11001, Saudi Arabia
关键词
SnO2-Co3O4; nanocubes; Hydrothermal method; Optical properties; Olmesartan medoxomil; I-V technique; Sensitivity; HPLC-METHOD; GAS SENSOR; SNO2; HYDROCHLOROTHIAZIDE; PERFORMANCE; AMLODIPINE; OXIDE; CO; FABRICATION; ATENOLOL;
D O I
10.1016/j.talanta.2012.07.060
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Low-dimensional nanoparticles composed SnO2-Co3O4 nanocubes (NCs) were prepared by a hydrothermal method using reducing agents. The doped nanomaterials were investigated by UV/vis, powder X-ray diffraction, FT-IR, energy-dispersive X-ray spectroscopy (EDS), and Raman spectroscopy, and field-emission scanning electron microscopy. They were deposited on a silver electrode (AgE, surface area, 0.0216 cm(2)) to give a drug sensor with a fast response towards Olmesartan medoxomil (OSM) in 0.1 mol L-1 phosphate buffer-phases. The sensor also exhibits higher sensitivity, long-term stability, and enhanced electrochemical response. The calibration plot is linear (r(2)=0.9948) over the 0.28 nmol L-1-1.4 mu M OSM concentration range. The sensitivity is similar to 2.083 mu A cm(-2) mmol L-1 and the detection limit is 0.17 nmol L-1 (at an SNR of 3). We discuss the possible potential uses of this nanoparticles doped semiconductor NCs in terms of drug sensing, which could also be employed for the determination of drugs in quality control of formulation. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:924 / 931
页数:8
相关论文
共 72 条
[1]   Simultaneous determination of atenolol and amlodipine in tablets by high-performance thin-layer chromatography [J].
Argekar, AP ;
Powar, SG .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2000, 21 (06) :1137-1142
[2]   MACROSCOPIC QUANTUM TUNNELING IN MAGNETIC PROTEINS [J].
AWSCHALOM, DD ;
SMYTH, JF ;
GRINSTEIN, G ;
DIVINCENZO, DP ;
LOSS, D .
PHYSICAL REVIEW LETTERS, 1992, 68 (20) :3092-3095
[3]   Stability-Indicating LC Determination of a New Antihypertensive, Olmesartan Medoxomil in Tablets [J].
Bajerski, Lisiane ;
Rossi, Rochele C. ;
Dias, Carolina L. ;
Bergold, Ana M. ;
Froehlich, Pedro E. .
CHROMATOGRAPHIA, 2008, 68 (11-12) :991-996
[4]   RP-LC and HPTLC Methods for the Determination of Olmesartan Medoxomil and Hydrochlorothiazide in Combined Tablet Dosage Forms [J].
Bari, P. D. ;
Rote, A. R. .
CHROMATOGRAPHIA, 2009, 69 (11-12) :1469-1472
[5]   The surface and materials science of tin oxide [J].
Batzill, M ;
Diebold, U .
PROGRESS IN SURFACE SCIENCE, 2005, 79 (2-4) :47-154
[6]   Determination of olmesartan medoxomil in tablets by UV-Vis spectrophotometry [J].
Celebier, M. ;
Altinoz, S. .
PHARMAZIE, 2007, 62 (06) :419-422
[7]   Development of a CZE method for the determination of Olmesartan medoxomil in tablets [J].
Celebier, Mustafa ;
Altinoez, Sacide .
CHROMATOGRAPHIA, 2007, 66 (11-12) :929-933
[8]  
Chabukswar A R., 2010, Archives of Applied Science Research, V2, P307
[9]   Room temperature ferromagnetism in Zn1-xCuxO thin films [J].
Chakraborti, D. ;
Narayan, J. ;
Prater, J. T. .
APPLIED PHYSICS LETTERS, 2007, 90 (06)
[10]   Sensing properties of Au-loaded SnO2-Co3O4 composites to CO and H2 [J].
Choi, US ;
Sakai, G ;
Shimanoe, K ;
Yamazoe, N .
SENSORS AND ACTUATORS B-CHEMICAL, 2005, 107 (01) :397-401