Influence of polymerization method, curing process, and length of time of storage in water on the residual methyl methacrylate content in dental acrylic resins

被引:57
作者
Bayraktar, G [1 ]
Guvener, B
Bural, C
Uresin, Y
机构
[1] Istanbul Univ, Fac Dent, Dept Removable Prosthodont, Istanbul, Turkey
[2] Istanbul Univ, Istanbul Fac Med, Expt Med Res Inst, Drug Res Unit, Istanbul, Turkey
[3] Istanbul Univ, Istanbul Fac Med, Dept Pharmacol & Clin Pharmacol, Istanbul, Turkey
关键词
dental/craniofacial material; clinical; prosthesis; polymerization; polymer;
D O I
10.1002/jbm.b.30377
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study compared the influence of different polymerization methods (heat, auto-, and microwave energy), different curing processes (in the case of heat- and autopolymerized specimens), and length of storage of the polymerized specimens in distilled water at 37 degrees C on the residual mnethyl methacrylate (MMA) content in dental acrylic resin specimens. Residual MMA of 120 resin specimens were measured using high-performance liquid chromatography. For the heat-polymerized resins, the lowest residual MMA content was obtained when they were given a long-term terminal boil and then stored in the distilled water for at least I day. For the autopolymerized resins, the lowest residual MMA content was obtained when they were additionally cured in water at 60 degrees C and then stored in the distilled water at least I day. For the microwave-polymerized resins, the lowest residual MMA content was obtained when they were stored in the distilled water at least I month. The lowest overall residual MMA content was obtained from heat-polymerized specimens that were given a long-term terminal boil cure and then stored in the distilled water at least 1 day. Different polymerization methods and curing processes have different effects on residual MMA content. It is thus shown that storing a dental acrylic resin specimen in distilled water at 37 degrees C is a simple but effective method of reducing its residual MMA content. (c) 2005 Wiley Periodicals, Inc.
引用
收藏
页码:340 / 345
页数:6
相关论文
共 35 条
[1]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF METHYL-METHACRYLATE IN INTRA-OCULAR LENSES [J].
AITZETMULLER, K ;
ECKERT, WR .
JOURNAL OF CHROMATOGRAPHY, 1978, 155 (01) :203-205
[2]  
Anusavice KJ., 1996, PHILLIPS SCI DENT MA, P237
[3]   PROPERTIES OF HIGHLY CROSS-LINKED AUTOPOLYMERIZING RELINE ACRYLIC RESINS [J].
ARIMA, T .
JOURNAL OF PROSTHETIC DENTISTRY, 1995, 73 (01) :55-59
[4]   THE LEVEL OF RESIDUAL MONOMER IN ACRYLIC DENTURE BASE MATERIALS - WITH PARTICULAR REFERENCE TO A MODIFIED METHOD OF ANALYSIS [J].
AUSTIN, AT ;
BASKER, RM .
BRITISH DENTAL JOURNAL, 1980, 149 (10) :281-286
[5]   Effect of the curing conditions on the properties of an acrylic denture base resin microwave-polymerised [J].
Azzarri, MJ ;
Cortizo, MS ;
Alessandrini, JL .
JOURNAL OF DENTISTRY, 2003, 31 (07) :463-468
[6]   THE RELEASE OF RESIDUAL MONOMERIC METHYL-METHACRYLATE FROM ACRYLIC APPLIANCES IN THE HUMAN MOUTH - AN ASSAY FOR MONOMER IN SALIVA [J].
BAKER, S ;
BROOKS, SC ;
WALKER, DM .
JOURNAL OF DENTAL RESEARCH, 1988, 67 (10) :1295-1299
[7]   Degree of conversion in denture base materials for varied polymerization techniques [J].
Bartoloni, JA ;
Murchison, DF ;
Wofford, DT ;
Sarkar, NK .
JOURNAL OF ORAL REHABILITATION, 2000, 27 (06) :488-493
[8]   Microwave polymerization of denture base materials. A comparative study [J].
Blagojevic, V ;
Murphy, VM .
JOURNAL OF ORAL REHABILITATION, 1999, 26 (10) :804-808
[9]  
Craig RC., 1997, RESTORATIVE DENT MAT, P500
[10]  
Cury AAD, 2001, J ORAL REHABIL, V28, P433