Repeatability of In Vivo Parafoveal Cone Density and Spacing Measurements

被引:126
|
作者
Garrioch, Robert [2 ,3 ]
Langlo, Christopher [4 ]
Dubis, Adam M.
Cooper, Robert F. [5 ]
Dubra, Alfredo [5 ,6 ,7 ]
Carroll, Joseph [1 ,5 ,6 ,7 ]
机构
[1] Med Coll Wisconsin, Inst Eye, Dept Cell Biol Neurobiol & Anat, Milwaukee, WI 53226 USA
[2] Med Coll Wisconsin, Summer Program Undergrad Res, Milwaukee, WI 53226 USA
[3] Cardiff Univ, Cardiff, S Glam, Wales
[4] Med Coll Wisconsin, Med Scientist Training Program, Milwaukee, WI 53226 USA
[5] Marquette Univ, Dept Biomed Engn, Milwaukee, WI 53233 USA
[6] Med Coll Wisconsin, Dept Ophthalmol, Milwaukee, WI 53226 USA
[7] Med Coll Wisconsin, Dept Biophys, Milwaukee, WI 53226 USA
基金
美国国家卫生研究院;
关键词
retina; cones; adaptive optics; repeatability; photoreceptors; PHOTORECEPTOR PACKING DENSITY; ADAPTIVE-OPTICS; RETINAL MOSAICS; RESOLUTION; REFLECTANCE; DISRUPTION; VISION;
D O I
10.1097/OPX.0b013e3182540562
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To assess the repeatability and measurement error associated with cone density and nearest neighbor distance (NND) estimates in images of the parafoveal cone mosaic obtained with an adaptive optics scanning light ophthalmoscope (AOSLO). Methods. Twenty-one participants with no known ocular pathology were recruited. Four retinal locations, approximately 0.65 degrees eccentricity from the center of fixation, were imaged 10 times in randomized order with an AOSLO. Cone coordinates in each image were identified using an automated algorithm (with or without manual correction) from which cone density and NND were calculated. Owing to naturally occurring fixational instability, the 10 images recorded from a given location did not overlap entirely. We thus analyzed each image set both before and after alignment. Results. Automated estimates of cone density on the unaligned image sets showed a coefficient of repeatability of 11,769 cones/mm(2) (17.1%). The primary reason for this variability appears to be fixational instability, as aligning the 10 images to include the exact same retinal area results in an improved repeatability of 4358 cones/mm(2) (6.4%) using completely automated cone identification software. Repeatability improved further by manually identifying cones missed by the automated algorithm, with a coefficient of repeatability of 1967 cones/mm(2) (2.7%). NND showed improved repeatability and was generally insensitive to the undersampling by the automated algorithm. Conclusions. As our data were collected in a young, healthy population, this likely represents a best-case estimate for corresponding measurements in patients with retinal disease. Similar studies need to be carried out on other imaging systems (including those using different imaging modalities, wavefront correction technology, and/or image analysis software), as repeatability would be expected to be highly sensitive to initial image quality and the performance of cone identification algorithms. Separate studies addressing intersession repeatability and interobserver reliability are also needed. (Optom Vis Sci 2012;89:632-643)
引用
收藏
页码:632 / 643
页数:12
相关论文
共 50 条
  • [31] Cone Identification in Choroideremia: Repeatability, Reliability, and Automation Through Use of a Convolutional Neural Network
    Morgan, Jessica I. W.
    Chen, Min
    Huang, Andrew M.
    Jiang, Yu You
    Cooper, Robert F.
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2020, 9 (02): : 1 - 13
  • [32] THE SPREAD OF ADAPTATION IN HUMAN FOVEAL AND PARAFOVEAL CONE VISION
    CICERONE, CM
    HAYHOE, MM
    MACLEOD, DIA
    VISION RESEARCH, 1990, 30 (11) : 1603 - 1615
  • [33] Fully Automated Estimation of Spacing and Density for Retinal Mosaics
    Cooper, Robert F.
    Aguirre, Geoffrey K.
    Morgan, Jessica I. W.
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2019, 8 (05):
  • [34] Intervisit Reproducibility of Foveal Cone Density Metrics
    Adhan, Iniya
    Warr, Emma
    Grieshop, Jenna
    Kreis, Joseph
    Nikezic, Danica
    Walesa, Ashleigh
    Hemsworth, Katherine
    Cooper, Robert F.
    Carroll, Joseph
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2024, 13 (06):
  • [35] Parafoveal cone function in choroideremia assessed with adaptive optics optoretinography
    Xu, Peiluo
    Cooper, Robert F.
    Jiang, Yu You
    Morgan, Jessica I. W.
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [36] Human Retinal Pigment Epithelium: In Vivo Cell Morphometry, Multispectral Autofluorescence, and Relationship to Cone Mosaic
    Granger, Charles E.
    Yang, Qiang
    Song, Hongxin
    Saito, Kenichi
    Nozato, Koji
    Latchney, Lisa R.
    Leonard, Bianca T.
    Chung, Mina M.
    Williams, David R.
    Rossi, Ethan A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (15) : 5705 - 5716
  • [37] In Vivo Longitudinal Measurement of Cone Photoreceptor Density in Intermediate Age-Related Macular Degeneration
    Wang, Xiaolin
    Sadda, Srinivas R.
    Ip, Michael S.
    Sarraf, David
    Zhang, Yuhua
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2023, 248 : 60 - 75
  • [38] Peak Cone Density Predicted from Outer Segment Length Measured on Optical Coherence Tomography
    Heitkotter, Heather
    Allphin, Mitchell T.
    Untaroiu, Ana
    Min, Heun
    Warr, Emma
    Wynne, Niamh
    Cooper, Robert F.
    Carroll, Joseph
    CURRENT EYE RESEARCH, 2024, 49 (03) : 314 - 324
  • [39] Distribution of cone density, spacing and arrangement in adult healthy retinas with adaptive optics flood illumination
    Legras, Richard
    Gaudric, Alain
    Woog, Kelly
    PLOS ONE, 2018, 13 (01):
  • [40] Repeatability and reproducibility of vessel density measurements on optical coherence tomography angiography in diabetic retinopathy
    Levine, Emily S.
    Arya, Malvika
    Chaudhari, Juhi
    Greig, Eugenia Custo
    Alibhai, A. Yasin
    Baumal, Caroline R.
    Witkin, Andre J.
    Duker, Jay S.
    Waheed, Nadia K.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2020, 258 (08) : 1687 - 1695