Resolution in scanning near-field cathodoluminescence microscopy

被引:4
作者
Pastré, D [1 ]
Bubendorff, JL [1 ]
Troyon, M [1 ]
机构
[1] Univ Reims, Unite Therm & Anal Phys, EA 2061, F-51685 Reims 2, France
来源
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B | 2000年 / 18卷 / 03期
关键词
D O I
10.1116/1.591349
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The lateral resolution in scanning near-field cathodoluminescence microscopy, in the case of bulk materials, is theoretically and experimentally studied. Although the theoretical resolution of near-field optical collection systems is determined by the probe size and thus should not be dependent on the energy dissipation volume in the material, it is theoretically shown that the contribution of the far-field signal caused by the radiative centers situated far from the probe can alter the resolution by adding a background noise to the near-field signal. In order to see the role of the energy dissipation volume, the electron beam accelerating voltage is varied and its influence on lateral resolution is studied in the case of a material that does not present a large energy transfer range, a fluorite doped with 0.3% europium. Cathodoluminescence images of this one confirm that the resolution is improved by working at low accelerating voltage to limit the energy dissipation volume, hence the contribution of the far-field radiative centers. On the other hand, for materials having a large energy transfer range (several micrometers) and therefore for which the far-field contribution can be strongly disturbing, the question concerning the efficiency of the near-field collection systems arises. Our experimental results on indented MgO crystal, which presents a large energy transfer range, demonstrates that near-field collection, despite the large contribution of the radiative centers situated far from the tip, gives still a better resolution than far-field collection. (C) 2000 American Vacuum Society. [S0734-211X(00)12903-8].
引用
收藏
页码:1138 / 1143
页数:6
相关论文
共 16 条
[1]   SOME PECULIARITIES OF THE CATHODOLUMINESCENCE OF INDENTED MGO CRYSTALS [J].
BOYARSKAYA, YS ;
NAZAROV, MV ;
NAZAROVA, TA ;
GAREEVA, AR ;
ZHITARU, RP .
PHYSICA STATUS SOLIDI A-APPLIED RESEARCH, 1994, 142 (01) :35-43
[2]   Enhanced cathodoluminescence from nano-indentations in MgO [J].
Chaudhri, MM .
PHILOSOPHICAL MAGAZINE LETTERS, 1998, 77 (01) :7-16
[3]   Near-field detection cathodoluminescence investigations [J].
Cramer, RM ;
Ebinghaus, V ;
Heiderhoff, R ;
Balk, LJ .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1998, 31 (15) :1918-1922
[4]  
Holt D. B., 2013, CATHODOLUMINESCENCE
[5]  
KERKER M, 1980, APPL OPTICS, V19, P4159, DOI [10.1364/AO.19.004159, 10.1364/AO.19.003373]
[6]   CATHODOLUMINESCENCE FROM DEFORMED CAO [J].
LLOPIS, J ;
PIQUERAS, J .
JOURNAL OF APPLIED PHYSICS, 1983, 54 (08) :4570-4572
[7]   Improvement of near-field fluorescence imaging of bulk materials by metal coating [J].
Pastré, D ;
Troyon, M .
EUROPEAN PHYSICAL JOURNAL-APPLIED PHYSICS, 1999, 6 (02) :179-188
[8]  
Pastré D, 1999, SURF INTERFACE ANAL, V27, P495, DOI 10.1002/(SICI)1096-9918(199905/06)27:5/6<495::AID-SIA485>3.0.CO
[9]  
2-I
[10]   Scanning near-field cathodoluminescence microscopy for semiconductor investigations:: A theoretical study [J].
Pastré, D ;
Troyon, M .