Quasi-static analysis of hip cement spacers

被引:4
作者
Mallek, Abdelhafid [1 ]
Miloudi, Abdelkader [2 ]
Khaldi, Mokhtar [3 ,4 ]
Bouziane, Mohammed-Mokhtar [1 ,4 ]
Bouiadjra, Belabbes Bachir [1 ]
Bougherara, Habiba [5 ]
Gill, Richie H. S. [6 ]
机构
[1] Univ Djillali Liabes Sidi Bel Abbes, Dept Mech Engn, LMPM, BP 89, Cite Ben Mhidi 22000, Sidi Bel Abbes, Algeria
[2] Univ Djillali Liabes Sidi Bel Abbes, Dept Mech Engn, LMSR, BP 89, Cite Ben Mhidi 22000, Sidi Bel Abbes, Algeria
[3] ENP Oran MA, Lab Appl Biomech & Biomat LABAB, Oran, Algeria
[4] Univ Mascara, Fac Technol, Dept Mech Engn, BP 305,Route Mamounia, Mascara 29000, Algeria
[5] Ryerson Univ, Dept Mech & Ind Engn, Toronto, ON, Canada
[6] Univ Bath, Dept Mech Engn, Ctr Orthoped Biomech, Bath, Avon, England
关键词
Orthopedic hip spacer; Quasi-static; Brittle cracking; XFEM; Reinforcement;
D O I
10.1016/j.jmbbm.2021.104334
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The use of temporary hip prosthesis made of orthopedic cement (spacer) in conjunction with antibiotics became a widespread method used for treating prosthetic infections despite the fact that this method makes bone cement (PMMA) more fragile. The necessity to incorporate reinforcement is therefore crucial to strengthen the bone cement. In this study, a validated Finite Element Modelling (FEM) was used to analyze the behavior of spacers. This FEM model uses a non-linear dynamic explicit integration to simulate the mechanical behavior of the spacer under quasi-static loading. In addition to this FEM, Extended Finite Element Method (XFEM) was also used to investigate the fracture behavior of the spacers reinforced with titanium, ceramic and stainless-steel spacer stems. The effect of the material on the performance of the reinforced spacers was also analyzed. The results showed that numerical modelling based on explicit finite element using ABAQUS/Explicit is an effective method to predict the different spacers' mechanical behavior. The simulated crack initiation and propagation were in a good agreement with experimental observations. The FEM models developed in this study can help mechanical designers and engineers to improve the prostheses' quality and durability.
引用
收藏
页数:12
相关论文
共 57 条
  • [41] Comparative study on the mechanical and fracture properties of acrylic bone cements prepared with monomers containing amine groups
    May-Pat, Alejandro
    Herrera-Kao, Wilberth
    Cauich-Rodriguez, Juan V.
    Cervantes-Uc, Jose M.
    Flores-Gallardo, Sergio G.
    [J]. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2012, 6 : 95 - 105
  • [42] Extended finite element method for cohesive crack growth
    Moës, N
    Belytschko, T
    [J]. ENGINEERING FRACTURE MECHANICS, 2002, 69 (07) : 813 - 833
  • [43] Web crippling failure using quasi-static FE models
    Natario, P.
    Silvestre, N.
    Camotim, D.
    [J]. THIN-WALLED STRUCTURES, 2014, 84 : 34 - 49
  • [44] A proximal fixed anatomic femoral stem reduces stress shielding
    Niinimäki, T
    Junila, J
    Jalovaara, P
    [J]. INTERNATIONAL ORTHOPAEDICS, 2001, 25 (02) : 85 - 88
  • [45] A new crack tip element for the phantom-node method with arbitrary cohesive cracks
    Rabczuk, Timon
    Zi, Goangseup
    Gerstenberger, Axel
    Wall, Wolfgang A.
    [J]. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN ENGINEERING, 2008, 75 (05) : 577 - 599
  • [46] Rots J.G. e., 1989, HERON, V34, P59
  • [47] Optimisation of a Reinforced Cement Spacer in Total Hip Arthroplasty
    Salah, H.
    Bouziane, M. M.
    Fekih, S. M.
    Bouiadjra, B. Bachir
    Benbarek, S.
    [J]. JOURNAL OF BIOMIMETICS BIOMATERIALS AND BIOMEDICAL ENGINEERING, 2018, 35 : 35 - 49
  • [48] Comparison of Three Fixation Methods for Femoral Neck Fracture in Young Adults: Experimental and Numerical Investigations
    Samsami, Shabnam
    Saberi, Sadegh
    Sadighi, Sanambar
    Rouhi, Gholamreza
    [J]. JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2015, 35 (05) : 566 - 579
  • [49] Individual bone cement spacers (IBCS) for septic hip revision - preliminary report
    Schoellner, C
    Fuerderer, S
    Rompe, JD
    Eckardt, A
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2003, 123 (05) : 254 - 259
  • [50] EFFECT OF MICROSTRUCTURE ON MEASUREMENTS OF FRACTURE ENERGY OF AL2O3
    SIMPSON, LA
    [J]. JOURNAL OF THE AMERICAN CERAMIC SOCIETY, 1973, 56 (01) : 7 - 11