Quasi-static analysis of hip cement spacers

被引:4
作者
Mallek, Abdelhafid [1 ]
Miloudi, Abdelkader [2 ]
Khaldi, Mokhtar [3 ,4 ]
Bouziane, Mohammed-Mokhtar [1 ,4 ]
Bouiadjra, Belabbes Bachir [1 ]
Bougherara, Habiba [5 ]
Gill, Richie H. S. [6 ]
机构
[1] Univ Djillali Liabes Sidi Bel Abbes, Dept Mech Engn, LMPM, BP 89, Cite Ben Mhidi 22000, Sidi Bel Abbes, Algeria
[2] Univ Djillali Liabes Sidi Bel Abbes, Dept Mech Engn, LMSR, BP 89, Cite Ben Mhidi 22000, Sidi Bel Abbes, Algeria
[3] ENP Oran MA, Lab Appl Biomech & Biomat LABAB, Oran, Algeria
[4] Univ Mascara, Fac Technol, Dept Mech Engn, BP 305,Route Mamounia, Mascara 29000, Algeria
[5] Ryerson Univ, Dept Mech & Ind Engn, Toronto, ON, Canada
[6] Univ Bath, Dept Mech Engn, Ctr Orthoped Biomech, Bath, Avon, England
关键词
Orthopedic hip spacer; Quasi-static; Brittle cracking; XFEM; Reinforcement;
D O I
10.1016/j.jmbbm.2021.104334
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The use of temporary hip prosthesis made of orthopedic cement (spacer) in conjunction with antibiotics became a widespread method used for treating prosthetic infections despite the fact that this method makes bone cement (PMMA) more fragile. The necessity to incorporate reinforcement is therefore crucial to strengthen the bone cement. In this study, a validated Finite Element Modelling (FEM) was used to analyze the behavior of spacers. This FEM model uses a non-linear dynamic explicit integration to simulate the mechanical behavior of the spacer under quasi-static loading. In addition to this FEM, Extended Finite Element Method (XFEM) was also used to investigate the fracture behavior of the spacers reinforced with titanium, ceramic and stainless-steel spacer stems. The effect of the material on the performance of the reinforced spacers was also analyzed. The results showed that numerical modelling based on explicit finite element using ABAQUS/Explicit is an effective method to predict the different spacers' mechanical behavior. The simulated crack initiation and propagation were in a good agreement with experimental observations. The FEM models developed in this study can help mechanical designers and engineers to improve the prostheses' quality and durability.
引用
收藏
页数:12
相关论文
共 57 条
  • [1] Abdullah Redzuan., 2007, Malaysian Journal of Civil Engineering, V19, P91, DOI DOI 10.11113/MJCE.V19.15748
  • [2] Affatato S, 2003, P I MECH ENG H, V217, P1
  • [3] Al-Rifaie A., 2017, Int. J. Civ. Environ. Eng., V11, P936
  • [4] Antimicrobial properties and elution kinetics of linezolid-loaded hip spacers in vitro
    Anagnostakos, Konstantinos
    Kelm, Jens
    Gruen, Sandra
    Schmitt, Eduard
    Jung, Wolfgang
    Swoboda, Stefanie
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2008, 87B (01) : 173 - 178
  • [5] Anagnostakos K, 2009, INT J MED SCI, V6, P274
  • [6] [Anonymous], 1984, BIOMATERIALS SCI ENG
  • [7] [Anonymous], S31673 UNS, DOI [10.1520/F0138-13A, DOI 10.1520/F0138-13A]
  • [8] [Anonymous], 1993, THESIS
  • [9] [Anonymous], ABAQUS DOCUMENTATION
  • [10] [Anonymous], 2002, Atlas of Stress-Strain Curves