We present a novel method for engineering an optical clock transition that is robust against external field fluctuations and is able to overcome limits resulting from field inhomogeneities. The technique is based on the application of continuous driving fields to form a pair of dressed states essentially free of all relevant shifts. Specifically, the clock transition is robust to magnetic field shifts, quadrupole and other tensor shifts, and amplitude fluctuations of the driving fields. The scheme is applicable to either a single ion or an ensemble of ions, and is relevant for several types of ions, such as Ca-40(+), Sr-88(+), Ba-138(+) and Lu-176(+). Taking a spherically symmetric Coulomb crystal formed by 400 Ca-40(+) ions as an example, we show through numerical simulations that the inhomogeneous linewidth of tens of Hertz in such a crystal together with linear Zeeman shifts of order 10 MHz are reduced to form a linewidth of around 1 Hz. We estimate a twoorder-of-magnitude reduction in averaging time compared to state-of-the art single ion frequency references, assuming a probe laser fractional instability of 10(-15). Furthermore, a statistical uncertainty reaching 2.9 x 10(-1)6 in 1 s is estimated for a cascaded clock scheme in which the dynamically decoupled Coulomb crystal clock stabilizes the interrogation laser for an Al-27(+) clock.
引用
收藏
页数:17
相关论文
共 16 条
  • [11] Robust Visual Tracking Using a Spatio-temporal Approach with Optical Flow
    Cheng, Chi-Cheng
    Ting, Shih-Hsiang
    2012 IEEE FIFTH INTERNATIONAL CONFERENCE ON ADVANCED COMPUTATIONAL INTELLIGENCE (ICACI), 2012, : 553 - 557
  • [12] Robust high-gain amplifier design using dynamical systems and bifurcation theory with digital postprocessing techniques
    He, Chengming
    Jin, Le
    Chen, Degang
    Geiger, Randy
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-REGULAR PAPERS, 2007, 54 (05) : 964 - 973
  • [13] Absolute frequency measurement of the 87Sr optical lattice clock at NTSC using international atomic time
    Lu, Xiaotong
    Guo, Feng
    Wang, Yebing
    Xu, Qinfang
    Zhou, Chihua
    Xia, Jingjing
    Wu, Wenjun
    Chang, Hong
    METROLOGIA, 2023, 60 (01)
  • [14] Suppression of servo error uncertainty to 10-18 level using double integrator algorithm in ion optical clock
    袁金波
    曹健
    崔凯枫
    刘道信
    袁易
    晁思嘉
    舒华林
    黄学人
    Chinese Physics B, 2021, (07) : 64 - 69
  • [15] All-optical clock recovery using a ridge width varied two-section partly gain-coupled DFB self-pulsation laser
    Kong, D. H.
    Zhu, H. L.
    Liang, S.
    Zhao, X. F.
    Lou, C. X.
    Wang, L.
    Wang, B. J.
    Zhao, L. J.
    OPTICS COMMUNICATIONS, 2010, 283 (20) : 3970 - 3975
  • [16] Frequency measurement of 6s6p 3P0,2-6s7s 3S1 transitions in ultracold 171Yb atoms referenced to local optical clock
    Qiao, Hao
    Sun, Chang-Yue
    Peng, Cheng-Quan
    Qi, Qi-Chao
    Zhao, Cheng-Cheng
    Zhou, Min
    Xu, Xin-Ye
    RESULTS IN PHYSICS, 2023, 48