Electrocoagulation removal of Cr(VI) from simulated wastewater using response surface methodology

被引:127
作者
Bhatti, Manpreet S. [1 ]
Reddy, Akepati S. [2 ]
Thukral, Ashwani K. [1 ]
机构
[1] Guru Nanak Dev Univ, Dept Bot & Environm Sci, Amritsar 143005, Punjab, India
[2] Thapar Univ, Dept Biotechnol & Environm Sci, Patiala 147001, Punjab, India
关键词
Cr(VI) reduction; Central composite design; Box-Cox plot; Energy consumption in electrocoagulation; Multiple response optimization; Design Expert software; ELECTROCHEMICAL TREATMENT; AQUEOUS-SOLUTION; BORON REMOVAL; ARSENIC REMOVAL; OPTIMIZATION; WASTEWATERS; DYE; COAGULATION; CHROMIUM; CADMIUM;
D O I
10.1016/j.jhazmat.2009.07.072
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The present study envisages the performance of a laboratory scale electrocoagulation system for the removal of Cr(VI) from 100 mg l(-1) solution using Al-Al electrodes with an effective surface area of 100 cm(2), and placed 15 mm apart. The interaction between voltage x time, and amperage x time best explained the Cr(VI) reduction efficiency with the coefficient of determination (R-2) being 0.8873 and 0.9270 respectively. Similarly, the square root of energy consumption in Cr(VI) reduction had a linear correlation with voltage x time (R-2 = 0.8949), whereas. amperage x time better explained energy consumption (R-2 = 0.9400). Response surface methodology was used for the optimization of process variables (pH, voltage and treatment time), response modeling and predictions. Maximum Cr(VI) reduction efficiency of 90.4% was achieved at pH 5, 24 V and 24 min treatment time, and the treatment consumed 137.2 KWh m(-3) of electrical energy. Multiple response optimization for maximizing Cr(VI) reduction efficiency and minimizing energy consumption showed 49.6% Cr(VI) removal at pH 5, 12.8 V and 24 min treatment time. The response models developed explained 95.2% variability for Cr(VI) reduction efficiency and 99.4% variability for energy consumption. Results of the prediction models were validated through laboratory scale batch experiments. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:839 / 846
页数:8
相关论文
共 42 条
[1]   Treatment of electroplating wastewater containing Cu2+, Zn2+ and Cr(VI) by electrocoagulation [J].
Adhoum, N ;
Monser, L ;
Bellakhal, N ;
Belgaied, JE .
JOURNAL OF HAZARDOUS MATERIALS, 2004, 112 (03) :207-213
[2]   Optimization of C.I. Acid Red 14 azo dye removal by electrocoagulation batch process with response surface methodology [J].
Aleboyeh, A. ;
Daneshvar, N. ;
Kasiri, M. B. .
CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2008, 47 (05) :827-832
[3]  
[Anonymous], 2004, DESIGN ANAL EXPT
[4]  
[Anonymous], 1984, GUID DRINK WAT QUAL
[5]  
APHA/AWWA/WEF, 2017, Standard Methods for the Examination of Water and Wastewater, V23rd
[6]   Treatment of azo dye production wastewaters using Photo-Fenton-like advanced oxidation processes: Optimization by response surface methodology [J].
Arslan-Alaton, Idil ;
Tureli, Gokce ;
Olmez-Hanci, Tugba .
JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2009, 202 (2-3) :142-153
[7]   Electrocoagulation of cutting oil emulsions using aluminium plate electrodes [J].
Bensadok, K. ;
Benammar, S. ;
Lapicque, F. ;
Nezzal, G. .
JOURNAL OF HAZARDOUS MATERIALS, 2008, 152 (01) :423-430
[8]  
Box G.E., 1978, STAT EXPT
[9]   AN ANALYSIS OF TRANSFORMATIONS [J].
BOX, GEP ;
COX, DR .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES B-STATISTICAL METHODOLOGY, 1964, 26 (02) :211-252
[10]   Electrochemical technologies in wastewater treatment [J].
Chen, GH .
SEPARATION AND PURIFICATION TECHNOLOGY, 2004, 38 (01) :11-41