Accuracy of five intraoral scanners compared to indirect digitalization

被引:148
作者
Gueth, Jan-Frederik [1 ]
Runkel, Cornelius [1 ]
Beuer, Florian [2 ]
Stimmelmayr, Michael [1 ]
Edelhoff, Daniel [1 ]
Keul, Christine [1 ]
机构
[1] Ludwig Maximilians Univ Munchen, Dept Prosthodont, Goethestr 70, D-80336 Munich, Germany
[2] Charite, Dept Prosthodont Geriatr Dent & Craniomandibular, Assmannshauser Str 4-6, D-14197 Berlin, Germany
关键词
Intraoral scanner; Accuracy; Digital impression; Impression; STL datasets; ARCH DENTAL IMPRESSIONS;
D O I
10.1007/s00784-016-1902-4
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Direct and indirect digitalization offer two options for computer-aided design (CAD)/ computer-aided manufacturing (CAM)-generated restorations. The aim of this study was to evaluate the accuracy of different intraoral scanners and compare them to the process of indirect digitalization. A titanium testing model was directly digitized 12 times with each intraoral scanner: (1) CS 3500 (CS), (2) Zfx Intrascan (ZFX), (3) CEREC AC Bluecam (BLU), (4) CEREC AC Omnicam (OC) and (5) True Definition (TD). As control, 12 polyether impressions were taken and the referring plaster casts were digitized indirectly with the D-810 laboratory scanner (CON). The accuracy (trueness/precision) of the datasets was evaluated by an analysing software (Geomagic Qualify 12.1) using a "best fit alignment" of the datasets with a highly accurate reference dataset of the testing model, received from industrial computed tomography. Direct digitalization using the TD showed the significant highest overall "trueness", followed by CS. Both performed better than CON. BLU, ZFX and OC showed higher differences from the reference dataset than CON. Regarding the overall "precision", the CS 3500 intraoral scanner and the True Definition showed the best performance. CON, BLU and OC resulted in significantly higher precision than ZFX did. Within the limitations of this in vitro study, the accuracy of the ascertained datasets was dependent on the scanning system. The direct digitalization was not superior to indirect digitalization for all tested systems. Regarding the accuracy, all tested intraoral scanning technologies seem to be able to reproduce a single quadrant within clinical acceptable accuracy. However, differences were detected between the tested systems.
引用
收藏
页码:1445 / 1455
页数:11
相关论文
共 17 条
[1]   Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques [J].
Almeida e Silva, Junio S. ;
Erdelt, Kurt ;
Edelhoff, Daniel ;
Araujo, Elito ;
Stimmelmayr, Michael ;
Cardoso Vieira, Luiz Clovis ;
Gueth, Jan-Frederik .
CLINICAL ORAL INVESTIGATIONS, 2014, 18 (02) :515-523
[2]  
[Anonymous], ISO 5725-1:1994 accuracy (trueness and precision) of measurement methods and results-Part 1: General principles and definitions
[3]   The state of fixed prosthodontic impressions - Room for improvement [J].
Christensen, GJ .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2005, 136 (03) :343-346
[4]   Will digital impressions eliminate the current problems with conventional impressions? [J].
Christensen, Gordon J. .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2008, 139 (06) :761-763
[5]  
Ender A, 2013, INT J COMPUT DENT, V16, P11
[6]  
Ender A, 2011, Int J Comput Dent, V14, P11
[7]   In-vitro evaluation of the accuracy of conventional and digital methods of obtaining full-arch dental impressions [J].
Ender, Andreas ;
Mehl, Albert .
QUINTESSENCE INTERNATIONAL, 2015, 46 (01) :9-17
[8]   ACCURACY OF COMPLETE-ARCH DENTAL IMPRESSIONS: A NEW METHOD OF MEASURING TRUENESS AND PRECISION [J].
Ender, Andreas ;
Mehl, Albert .
JOURNAL OF PROSTHETIC DENTISTRY, 2013, 109 (02) :121-128
[9]   Accuracy of digital models obtained by direct and indirect data capturing [J].
Gueth, Jan-Frederik ;
Keul, Christine ;
Stimmelmayr, Michael ;
Beuer, Florian ;
Edelhoff, Daniel .
CLINICAL ORAL INVESTIGATIONS, 2013, 17 (04) :1201-1208
[10]  
Henkel Gary L, 2007, Compend Contin Educ Dent, V28, P422