Experimental study on bolted and anchored beam-to-column joints of prefabricated concrete frames

被引:13
作者
Zhang, Xizhi [1 ,2 ]
Hao, Jiashu [3 ]
Duan, Dongchao [3 ]
Xu, Shengbo [3 ]
Zhang, Shaohua [3 ]
Yu, Houxin [4 ]
机构
[1] Tianjin Univ, Res Inst Architectural Design & Urban Planning, Tianjin, Peoples R China
[2] Tianjin Univ, Key Lab Civil Engn Struct & New Mat, Tianjin, Peoples R China
[3] Tianjin Univ, Sch Civil Engn, 92 Weijin Rd, Tianjin 300072, Peoples R China
[4] Tianjin Port Grp Co Ltd, Tianjin, Peoples R China
基金
中国国家自然科学基金;
关键词
beam-to-column joints; cyclic loading test; prefabricated; seismic behavior; steel fastener; SEISMIC PERFORMANCE; PRECAST; CONNECTIONS; DAMAGE;
D O I
10.1177/1369433219872432
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A new type of beam-to-column joint used in prefabricated concrete frames was proposed in this study. In this joint, the longitudinal bars at the top of the beam are anchored to the column using straight thread sleeves, and the bars at the bottom are welded to the steel fastener that is bolted to the column. Cyclic loading tests of three specimens, namely, two beam-column joints of this type and a cast-in-place beam-column joint, were conducted to study the seismic behavior and feasibility of this type of joint. The difference between the two prefabricated joints is the shape of the holes on the end plate. Failure modes of the specimens were observed and analyzed. The hysteretic curves, bearing capacities, stiffness degeneration, ductility, and energy-dissipating capacities of the specimens were compared and studied. Test results indicated that all beam-column joints exhibited beam hinge failure. No slippage was observed between the concrete and horizontal plates of the steel fasteners used in the new type of joint. The bearing capacity and initial stiffness of both prefabricated specimens compared with the cast-in-place ones were increased. The steel fastener could increase the distance between the plastic hinge and the side surface of the column while enlarging the length of the plastic hinge. The trend of energy dissipation and stiffness degeneration of the specimens were similar, and the ductility coefficient ranged from 2.7 to 4.91. The displacement angles of the joints exceeded 1/50 before the failure of the specimens. The mechanical behavior of both prefabricated joints was similar, but the joint with U-shaped holes on the end plate was convenient to create.
引用
收藏
页码:374 / 387
页数:14
相关论文
共 19 条
[1]   Damage and failure pattern of prefabricated structures after major earthquakes in Turkey and shortfalls of the Turkish Earthquake code [J].
Arslan, MH ;
Korkmaz, HH ;
Gulay, FG .
ENGINEERING FAILURE ANALYSIS, 2006, 13 (04) :537-557
[2]   Experimental Investigation on the Seismic Performance of Large-Scale Interior Beam-Column Joints with Composite Slab [J].
Chen, Shicai ;
Yan, Weiming ;
Gao, Jie .
ADVANCES IN STRUCTURAL ENGINEERING, 2012, 15 (07) :1227-1237
[3]  
Cheok G.S., 1993, PCI J, V38, P80, DOI 10.15554/ pcij.07011993.80.92
[4]  
Cheok G.S., 1991, PCI J, V36, P56, DOI DOI 10.15554/PCIJ.05011991.56.67
[5]   Ductile connections in precast concrete moment resisting frames [J].
Ertas, O ;
Ozden, S ;
Ozturan, T .
PCI JOURNAL, 2006, 51 (03) :66-+
[6]   Experimental study of a new beam-to-column connection for precast concrete frames under reversal cyclic loading [J].
Guan, Dongzhi ;
Guo, Zhengxing ;
Xiao, Quandong ;
Zheng, Yongfeng .
ADVANCES IN STRUCTURAL ENGINEERING, 2016, 19 (03) :529-545
[7]  
Gulkan P, 1998, 9801 METUDMC
[8]   Performance Evaluation of Semi Precast Concrete Beam-Column Connections with U-Shaped Strands [J].
Ha, Sang-Su ;
Kim, Seung-Hun ;
Lee, Moon Sung ;
Moon, Jeong-Ho .
ADVANCES IN STRUCTURAL ENGINEERING, 2014, 17 (11) :1585-1600
[9]   Prestressed bolting in precast concrete beam-column connection [J].
Hanaor, A ;
Ben-Arroyo, A .
PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 1998, 128 (02) :144-153
[10]   Finite element analysis of precast hybrid-steel concrete connections under cyclic loading [J].
Kulkarni, Sudhakar A. ;
Li, Bing ;
Yip, Woon Kwong .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2008, 64 (02) :190-201