Is CT bulletproof? On the use of CT for characterization of bullets in forensic radiology

被引:14
作者
Paulis, L. E. [1 ]
Kroll, J. [1 ]
Heijnens, L. [1 ]
Huijnen, M. [2 ]
Gerretsen, R. [3 ]
Backes, W. H. [1 ]
Hofman, P. A. M. [1 ]
机构
[1] Maastricht Univ, Med Ctr, Dept Radiol & Nucl Med, POB 5800, NL-6202 AZ Maastricht, Netherlands
[2] Dutch Police, POB 1230, NL-6201 BE Maastricht, Netherlands
[3] Netherlands Forens Inst, POB 24044, NL-2490 AA The Hague, Netherlands
关键词
Forensic radiology; CT; Bullet; Metal; Material identification; Beam hardening; Photon starvation; COMPUTED-TOMOGRAPHY; INCONSISTENCY; IMAGE; MRI;
D O I
10.1007/s00414-019-02033-0
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
Purpose Forensic investigations could benefit from non-invasive in situ characterization of bullets. Therefore, the use of CT imaging was explored for the analysis of bullet geometry and composition. Bullet visualization with CT is challenging as the metal constituents suffer from excessive X-ray attenuation due to their high atomic number, density, and geometry. Methods A metal reference phantom was developed containing small discs of various common metals (aluminum, iron, stainless steel, copper, brass, tungsten, and lead). CT images were acquired with 70-150 kVp and 200-400 mAs and were reconstructed using an extended Hounsfield unit (HU) scale (- 10,240 to + 30,710). For each material, the mean CT number (HU) was measured to construct a metal database. Different bullets (n = 11) were scanned in a soft tissue-mimicking phantom. Bullet size and shape were measured, and composition was evaluated by comparison with the metal database. Also, the effect of bullet orientation within the CT scanner was evaluated. Results In the reference phantom, metals were classified into three groups according to their atomic number (Z): low (Z <= 13; HU < 3000), medium (Z = 25-30; HU = 13,000-20,000), and high (Z >= 74; HU > 30,000). External bullet contours could be accurately delineated. Internal interfaces between jacket and core could not be identified. Cross-sectional spatial profile plots of the CT number along bullets' short axis revealed beam hardening and photon starvation effects that depended on bullet size, shape, and orientation within the CT scanner. Therefore, the CT numbers of bullets were unreliable and could not be used for material characterization by comparison with the reference phantom. Conclusion CT-based characterization of bullets was feasible in terms of size and shape but not composition.
引用
收藏
页码:1869 / 1877
页数:9
相关论文
共 18 条
  • [1] [Anonymous], 2008, WUNDBALLISTIK
  • [2] Artifacts in CT: Recognition and avoidance
    Barrett, JF
    Keat, N
    [J]. RADIOGRAPHICS, 2004, 24 (06) : 1679 - 1691
  • [3] Boas FE., 2012, IMAGING MED, V4, P229, DOI [DOI 10.2217/IIM.12.13, 10.2217/iim.12.13]
  • [4] Bushberg J.T., 2012, ESSENTIAL PHYS MED I, V3
  • [5] Inconsistency in 9 mm bullets measured with non-destructive X-ray computed tomography
    Kumar, Jagadeesha
    Landheer, Dirk
    Barnes-Warden, Jane
    Fenne, Paul
    Attridge, Alex
    Williams, Mark A.
    [J]. FORENSIC SCIENCE INTERNATIONAL, 2012, 214 (1-3) : 48 - 58
  • [6] Can postmortem MRI be used to assess trajectories in gunshot victims?
    Luijten, M.
    Haest, I. I. H.
    van Kan, R. A. T.
    van Lohuizen, W.
    Kroll, J.
    Schnerr, R. S.
    Hermsen, R.
    Hofman, P. A. M.
    [J]. INTERNATIONAL JOURNAL OF LEGAL MEDICINE, 2016, 130 (02) : 457 - 462
  • [7] Utilization of X-ray Computed Tomography for the Exclusion of a Specific Caliber and Bullet Type in a Living Shooting Victim
    Marais, Adriaan A. S.
    Dicks, Herman J.
    [J]. JOURNAL OF FORENSIC SCIENCES, 2019, 64 (01) : 264 - 269
  • [8] McGuire MF, 2008, STAINLESS STEELS DES
  • [9] Post-mortem radiology-a new sub-speciality?
    O'Donnell, C.
    Woodford, N.
    [J]. CLINICAL RADIOLOGY, 2008, 63 (11) : 1189 - 1194
  • [10] Forensic pathological aspects of postmortem imaging of gunshot injury to the head:: documentation and biometric data
    Oehmichen, M
    Gehl, HB
    Meissner, C
    Petersen, D
    Höche, W
    Gerling, I
    König, HG
    [J]. ACTA NEUROPATHOLOGICA, 2003, 105 (06) : 570 - 580