Multicenter evaluation of the new immunoassay method for TSH measurement using the automated DxI platform

被引:10
|
作者
Dittadi, Ruggero [1 ]
Rizzardi, Sara [2 ]
Masotti, Silvia [3 ,4 ]
Prontera, Concetta [3 ,4 ]
Ripoli, Andrea [3 ,4 ]
Fortunato, Antonio [5 ,13 ]
Alfano, Antonio [6 ]
Carrozza, Cinzia [7 ]
Correale, Mario [8 ]
Gessoni, Gianluca [9 ]
Migliardi, Marco [10 ]
Zucchelli, Giancarlo [11 ,12 ]
Clerico, Aldo [3 ,4 ]
机构
[1] Osped Angelo, Lab Med Dept, UOC Lab Anal, ULSS 12 Veneziana, Venice, Italy
[2] Azienda Sociosanitaria Terr Cremona, Lab Med Dept, UO Lab Anal, Cremona, Italy
[3] Fdn CNR Reg Toscana Gabriele Monasterio, Pisa, Italy
[4] Scuola Super Sant Anna, Pisa, Italy
[5] Osped San Bortolo, Lab Chim Clin Ematol, Vicenza, Italy
[6] Hosp ASL T04, Clin Pathol, Turin, Italy
[7] Univ Cattolica Sacro Cuore, Policlin A Gemelli, UO Anal Ormonali & Biol Mol Clin, Rome, Italy
[8] IRCCS Bellis, Clin Pathol Unit, Bari, Italy
[9] Osped Madonna Navicella, Serv Med Lab, Chioggia, Italy
[10] AO Ordine Mauriziano Torino, SC Lab Anal, Turin, Italy
[11] QualiMedLab, Pisa, Italy
[12] CNR Clin Physiol Inst, Pisa, Italy
[13] ASUR Marche Area Vasta 5, UOC Patol Clin, Ascoli Piceno, Italy
关键词
TSH; Immunoassay methods; Quality control; Quality specification; DxI platform; Beckman coulter; THYROID-FUNCTION; HARMONIZATION; STANDARDIZATION; TESTS;
D O I
10.1016/j.cca.2017.02.006
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Aim of the study: Recently, Beckman Coulter Diagnostics set up a new TSH immunoassay for the automated DxI platform. The aim of this study was to evaluate and compare the analytical performance and clinical results of this method with those of previous method. Material and methods: A multicenter study (named TSH ELAS Study) was organized using 593 serum samples, collected from healthy subjects and patients with thyroid disorders, and 13 control samples, circulated in an External Quality Assessment (EQA) scheme. Results: The values of LoB and LoD, and LoQat 20% CV were 0.0004 mIU/L, 0.001 mIU/L and 0.0023 mIU/L, respectively. Moreover, TSH concentrations >0.01 mIU/L actually show imprecision values lower than 5% CV. This new TSH assay showed a systematic underestimation (on average of 6.25%) compared to old method, which is mainly due to larger differences between methods for samples with low TSH concentrations, related to the better analytical sensitivity of new compared to old method. In a reference population, including 279 apparently healthy adult subjects, Caucasian volunteers (mean age 43.6 years, age 20-63 years, 138 women and 141 males) the distribution of TSH concentrations was: mean (CI 95%) 1.694 mIU/L (1.588-1.779), median 1.495 mIU/L (1.412-1.588 mIU/L), 97.5th percentile 3.707 mIU/L. Conclusions: The new TSH immunoassay for DxI platform shows some relevant improvements compared to the previous one: use of the most recent WHO 3rd IRP 81/563 standard and monoclonal antibodies (instead of poly clonal antibodies of the old method), and better analytical sensitivities and reproducibility. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:105 / 110
页数:6
相关论文
共 15 条
  • [1] EVALUATION OF PRECISION AND RELATIVE ACCURACY OF A NEW AUTOMATED LUMINESCENCE IMMUNOASSAY FOR TSH AND FT4
    PILO, A
    ZUCCHELLI, GC
    CHIESA, MR
    JOURNAL OF CLINICAL IMMUNOASSAY, 1994, 17 (03): : 176 - 182
  • [2] Evaluation of Beckman Coulter DxI 800 immunoassay system using clinically oriented performance goals
    Akbas, Neval
    Schryver, Patricia G.
    Algeciras-Schimnich, Alicia
    Baumann, Nikola A.
    Block, Darci R.
    Budd, Jeffrey R.
    Gaston, S. J. Stephen
    Klee, George G.
    CLINICAL BIOCHEMISTRY, 2014, 47 (16-17) : 158 - 163
  • [3] Cross-method comparison of serum androstenedione measurement with respect to the validation of a new fully automated chemiluminescence immunoassay
    van Helden, Josef
    Weiskirchen, Ralf
    CLINICAL BIOCHEMISTRY, 2018, 62 : 32 - 38
  • [4] Multicenter Evaluation of a New High-Throughput HbA1c Testing Platform
    Imdahl, R.
    Roeddiger, R.
    Casis-Saenz, E.
    CLINICAL LABORATORY, 2016, 62 (12) : 2405 - 2412
  • [5] Discriminating Normal from "Abnormal" Pregnancy Cases Using an Automated FHR Evaluation Method
    Spilka, Jiri
    Georgoulas, George
    Karvelis, Petros
    Chudacek, Vaclav
    Stylios, Chrysostomos D.
    Lhotska, Lenka
    ARTIFICIAL INTELLIGENCE: METHODS AND APPLICATIONS, 2014, 8445 : 521 - 531
  • [6] New method of metrological evaluation of industrial rolling bearing vibration measurement systems
    Wrzochal, Mateusz
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2023, 124 (1-2): : 587 - 600
  • [7] New method of metrological evaluation of industrial rolling bearing vibration measurement systems
    Mateusz Wrzochal
    The International Journal of Advanced Manufacturing Technology, 2023, 124 : 587 - 600
  • [8] Evaluation of a standardized protocol for thrombin generation measurement using the calibrated automated thrombogram: An international multicentre study
    Dargaud, Yesim
    Wolberg, Alisa S.
    Luddington, Roger
    Regnault, Veronique
    Spronk, Henri
    Baglin, Trevor
    Lecompte, Thomas
    Ten Cate, Hugo
    Negrier, Claude
    THROMBOSIS RESEARCH, 2012, 130 (06) : 929 - 934
  • [9] A multicenter clinical evaluation of Mycobacterium tuberculosis IgG/IgM antibody detection using the colloidal gold method
    Wang, Y.
    Lu, B.
    Liu, J.
    Xiao, T.
    Wan, K.
    Guan, C.
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2014, 33 (11) : 1989 - 1994
  • [10] Evaluation of an Automated Screening Assay, Compared to Indirect Immunofluorescence, an Extractable Nuclear Antigen Assay, and a Line Immunoassay in a Large Cohort of Asian Patients with Antinuclear Antibody-Associated Rheumatoid Diseases: A Multicenter Retrospective Study
    Jeong, Seri
    Hwang, Hyunyong
    Roh, Juhye
    Shim, Jung Eun
    Kim, Jinmi
    Kim, Geun-Tae
    Tag, Hee-Sang
    Kim, Hyon-Suk
    JOURNAL OF IMMUNOLOGY RESEARCH, 2018, 2018