A prospective multicenter study of endoscopic ultrasound-guided fine needle biopsy using a 22-gauge Franseen needle for pancreatic solid lesions

被引:12
|
作者
Ishigaki, Kazunaga [1 ]
Nakai, Yousuke [1 ,2 ]
Sasahira, Naoki [3 ]
Sugimori, Kazuya [10 ]
Kitamura, Katsuya [4 ,5 ]
Iwai, Tomohisa [11 ]
Matsubara, Saburo [12 ]
Shimura, Kenji [14 ]
Itoi, Takao [6 ]
Ryozawa, Shomei [13 ]
Ushio, Jun [15 ]
Doi, Shinpei [16 ]
Imazu, Hiroo [7 ]
Maetani, Iruru [8 ]
Isayama, Hiroyuki [9 ]
机构
[1] Univ Tokyo, Grad Sch Med, Dept Gastroenterol, Tokyo, Japan
[2] Univ Tokyo, Grad Sch Med, Dept Endoscopy & Endoscop Surg, Tokyo, Japan
[3] Tokyo Med Univ, Canc Inst Hosp JFCR, Dept Gastroenterol, Hachioji Med Ctr, Tokyo, Japan
[4] Tokyo Med Univ, Dept Gastroenterol & Hepatol, Hachioji Med Ctr, Tokyo, Japan
[5] Showa Univ, Sch Med, Dept Med, Div Gastroenterol, Tokyo, Japan
[6] Tokyo Med Univ Hosp, Dept Gastroenterol, Tokyo, Japan
[7] Nihon Univ, Dept Gastroenterol, Itabashi Hosp, Tokyo, Japan
[8] Toho Univ, Div Gastroenterol & Hepatol, Dept Internal Med, Ohashi Med Ctr, Tokyo, Japan
[9] Juntendo Univ, Grad Sch Med, Dept Gastroenterol, Tokyo, Japan
[10] Yokohama City Univ, Gastroentel Ctr, Med Ctr, Yokohama, Kanagawa, Japan
[11] Kitasato Univ Hosp, Dept Gastroenterol, Sagamihara, Kanagawa, Japan
[12] Saitama Med Univ, Dept Gastroenterol & Hepatol, Saitama Med Ctr, Saitama, Japan
[13] Saitama Med Univ, Dept Gastroenterol, Int Med Ctr, Saitama, Japan
[14] Asahi Gen Hosp, Dept Gastroenterol, Chiba, Japan
[15] Jichi Med Univ Hosp, Dept Gastroenterol, Shimotsuke, Tochigi, Japan
[16] Teikyo Univ Hosp, Dept Gastroenterol, Kawasaki, Kanagawa, Japan
关键词
endoscopic ultrasound; endoscopic ultrasound‐ guided fine needle aspiration; fine‐ needle biopsy; pancreatic neoplasms; DIAGNOSTIC-ACCURACY; EUS-FNA; ASPIRATION; METAANALYSIS; STANDARD; SUCTION; MASSES; YIELD;
D O I
10.1111/jgh.15534
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and Aim While encouraging data of endoscopic ultrasound (EUS)-guided fine-needle biopsy (EUS-FNB) using a 22-gauge Franseen needle have been reported, large-scale data of per pass and quantitative analyses are still lacking. Methods This was a multicenter prospective study of EUS-FNB using the 22-gauge Franseen needle for a pancreatic solid lesion. Cytological and histological analyses per pass were evaluated and semi-quantitative analyses were performed on core tissue and blood contamination. Primary end-point was diagnostic accuracy per session. Prognostic factors were analyzed for diagnostic accuracy, sensitivity, core tissue, and blood contamination. Results A total of 629 passes were performed in 244 cases at 14 centers between 2018 and 2019. The median tumor size was 29 mm, and the puncture was transduodenal in 43%. The median pass number was 2. Diagnostic accuracy per session, at a first pass, and per pass were 93%, 90%, and 88%. In 198 cases with pancreatic cancer, diagnostic sensitivity per session, at a first pass, and per pass were 94%, 89%, and 89%. The rates of core tissue score of 4 and blood contamination score of 3 were 50% and 47%. The adverse event rate was 1.6%. In the multivariate analysis, tumor size <= 20 mm (odds ratio [OR] of 0.46, P = 0.03), transduodenal puncture (OR of 0.53, P = 0.04), and suction (OR of 0.16, P = 0.01) were associated with lower diagnostic accuracy. Conclusions The EUS-FNB using the 22-gauge Franseen needle for pancreatic solid lesions showed high per pass and overall diagnostic accuracy.
引用
收藏
页码:2754 / 2761
页数:8
相关论文
共 50 条
  • [1] Endoscopic ultrasound-guided fine-needle biopsy of small solid pancreatic lesions using a 22-gauge needle with side fenestration
    Fabbri, Carlo
    Luigiano, Carmelo
    Maimone, Antonella
    Tarantino, Ilaria
    Baccarini, Paola
    Fornelli, Adele
    Liotta, Rosa
    Polifemo, Annamaria
    Barresi, Luca
    Traina, Mario
    Virgilio, Clara
    Cennamo, Vincenzo
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2015, 29 (06): : 1586 - 1590
  • [2] Endoscopic ultrasound-guided fine needle aspiration and biopsy using a 22-gauge needle with side fenestration in pancreatic cystic lesions
    Barresi, Luca
    Tarantino, Ilaria
    Traina, Mario
    Granata, Antonino
    Curcio, Gabriele
    Azzopardi, Neville
    Baccarini, Paola
    Liotta, Rosa
    Fornelli, Adele
    Maimone, Antonella
    Jovine, Elio
    Cennamo, Vincenzo
    Fabbri, Carlo
    DIGESTIVE AND LIVER DISEASE, 2014, 46 (01) : 45 - 50
  • [3] Endoscopic ultrasound-guided fine-needle biopsy of small solid pancreatic lesions using a 22-gauge needle with side fenestration
    Carlo Fabbri
    Carmelo Luigiano
    Antonella Maimone
    Ilaria Tarantino
    Paola Baccarini
    Adele Fornelli
    Rosa Liotta
    Annamaria Polifemo
    Luca Barresi
    Mario Traina
    Clara Virgilio
    Vincenzo Cennamo
    Surgical Endoscopy, 2015, 29 : 1586 - 1590
  • [4] Endoscopic Ultrasound-Guided Tissue Acquisition by 22-Gauge Franseen and Standard Needles for Solid Pancreatic Lesions
    Ishigaki, Kazunaga
    Nakai, Yousuke
    Oyama, Hiroki
    Kanai, Sachiko
    Suzuki, Tatsunori
    Nakamura, Tomoka
    Sato, Tatsuya
    Hakuta, Ryunosuke
    Saito, Kei
    Saito, Tomotaka
    Takahara, Naminatsu
    Hamada, Tsuyoshi
    Mizuno, Suguru
    Kogure, Hirofumi
    Tada, Minoru
    Isayama, Hiroyuki
    Koike, Kazuhiko
    GUT AND LIVER, 2020, 14 (06) : 817 - 825
  • [5] Comparison of Endoscopic Ultrasound-Guided Fine Needle Aspiration with 19-Gauge and 22-Gauge Needles for Solid Pancreatic Lesions
    Li, Changjuan
    Mi, Jianwei
    Gao, Fulai
    Zhu, Xinying
    Su, Miao
    Xie, Xiaoli
    Zhao, Dongqiang
    INTERNATIONAL JOURNAL OF GENERAL MEDICINE, 2021, 14 : 10439 - 10446
  • [6] Performance of a new needle for endoscopic ultrasound-guided fine-needle biopsy in patients with pancreatic solid lesions: A retrospective multicenter study
    Di Mitri, Roberto
    Rimbas, Mihai
    Attili, Fabia
    Fabbri, Carlo
    Carrara, Silvia
    Di Maurizio, Luca
    Inzani, Frediano
    Repici, Alessandro
    Gasbarrini, Antonio
    Costamagna, Guido
    Larghi, Alberto
    ENDOSCOPIC ULTRASOUND, 2018, 7 (05) : 329 - 334
  • [7] Comparison of endoscopic ultrasound guided 22-gauge core needle with standard 25-gauge fine-needle aspiration for diagnosing solid pancreatic lesions
    Berzosa, Manuel
    Villa, Nicolas
    El-Serag, Hasheme B.
    Sejpal, Divyesh V.
    Patel, Kalpesh K.
    ENDOSCOPIC ULTRASOUND, 2015, 4 (01) : 28 - 33
  • [8] 22-gauge core vs 22-gauge aspiration needle for endoscopic ultrasound-guided sampling of abdominal masses
    Sterlacci, William
    Sioulas, Athanasios D.
    Veits, Lothar
    Goenuellue, Pervin
    Schachschal, Guido
    Groth, Stefan
    Anders, Mario
    Kontos, Christos K.
    Topalidis, Theodoros
    Hinsch, Andrea
    Vieth, Michael
    Roescch, Thomas
    Denzer, Ulrike W.
    WORLD JOURNAL OF GASTROENTEROLOGY, 2016, 22 (39) : 8820 - 8830
  • [9] Diagnostic Yield of Repeat Endoscopic Ultrasound-Guided Fine Needle Biopsy for Solid Pancreatic Lesions
    Camus, Baptiste
    Pellat, Anna
    Rouquette, Alexandre
    Marchese, Ugo
    Dohan, Anthony
    Belle, Arthur
    Abou Ali, Einas
    Chaussade, Stanislas
    Coriat, Romain
    Barret, Maximilien
    CANCERS, 2023, 15 (14)
  • [10] Comparison of 22-gauge standard fine needle versus core biopsy needle for endoscopic ultrasound-guided sampling of suspected pancreatic cancer: a randomized crossover trial
    Noh, Dong Hyo
    Choi, Kyu
    Gu, Seonhye
    Cho, Juhee
    Jang, Kee-Taek
    Woo, Young Sik
    Lee, Kyu Taek
    Lee, Jong Kyun
    Lee, Kwang Hyuck
    SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 2018, 53 (01) : 94 - 99