Reproducibility of p53 and Ki-67 immunoquantitation in Barrett's esophagus

被引:0
作者
Polkowski, W
Meijer, GA
Baak, JPA
tenKate, FJW
Obertop, H
Offerhaus, GJA
vanLanschot, JJB
机构
[1] FREE UNIV AMSTERDAM HOSP,DEPT PATHOL,NL-1007 MB AMSTERDAM,NETHERLANDS
[2] UNIV AMSTERDAM,ACAD MED CTR,DEPT SURG,NL-1105 AZ AMSTERDAM,NETHERLANDS
[3] UNIV AMSTERDAM,ACAD MED CTR,DEPT PATHOL,NL-1105 AZ AMSTERDAM,NETHERLANDS
[4] MED ACAD,DEPT GEN SURG 2,LUBLIN,POLAND
来源
ANALYTICAL AND QUANTITATIVE CYTOLOGY AND HISTOLOGY | 1997年 / 19卷 / 03期
关键词
immunohistochemistry; image cytometry; Barrett esophagus; p53; Ki-67; quantitative pathology;
D O I
暂无
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
OBJECTIVE: To test the reproducibility and time Effectiveness of two immunoquantitation and sampling methods in Barrett's esophagus (BE) mucosa. STUDY DESIGN: Measurements were performed using image cytometry (CAS 200/486) with ''at convenience'' sampling and stereology (QPRODIT 5.2) with both at convenience and systematic random sampling. RESULTS: Quantitation of p53 immunohistochemistry (IHC) by CAS was very reproducible by the same observer (r = .99), but its interobserver reproducibility was lower, and the measurement was time consuming (r = .81, 35 minutes). Moreover, CAS also detected a ''signal'' in the absence of any visually observable brown stain, giving false positive results. Both intraobserver and interobserver reproducibility by QPRODIT 5.2 were good. With QPRODIT, using systematic random sampling, the measurements were more reproducible by different observers and faster (r = .96, 10 minutes) than with QPRODIT with at convenience sampling (r = .91, 20 minutes). Therefore, for assessment of the Ki-67 labelling index (LI) and area percentage (area%) of Ki-67-positive nuclei, we used only QPRODIT with systematic random sampling. While intraobserver reproducibility of both Ki-67 LI and area% was good (r = .96, r = .99), interobserver reproducibility of Ki-67 LI was poorer than area% (r = .72 vs, r = .97). The assessment of Ki-67 LI was time consuming, whereas the measurement of the area% of Ki-67-positive nuclei was very time effective (45 vs. 7 minutes). A strong correlation was found between Ki-67 LI and area% of Ki-67-positive nuclei (r = .92). CONCLUSION: Therefore, we conclude that quantitation of p53 and Ki-67 IHC in BE mucosa can be very reproducible and highly time effective by means of stereology with systematic random sampling.
引用
收藏
页码:246 / 254
页数:9
相关论文
共 23 条
[1]   HIGH-GRADE DYSPLASIA IN THE COLUMNAR-LINED ESOPHAGUS [J].
ALTORKI, NK ;
SUNAGAWA, M ;
LITTLE, AG ;
SKINNER, DB .
AMERICAN JOURNAL OF SURGERY, 1991, 161 (01) :97-100
[2]   EVALUATION OF 6 ANTIBODIES FOR IMMUNOHISTOCHEMISTRY OF MUTANT P53 GENE-PRODUCT IN ARCHIVAL COLORECTAL NEOPLASMS [J].
BAAS, IO ;
MULDER, JWR ;
OFFERHAUS, GJA ;
VOGELSTEIN, B ;
HAMILTON, SR .
JOURNAL OF PATHOLOGY, 1994, 172 (01) :5-12
[3]  
BLOUNT PL, 1991, CANCER RES, V51, P5482
[4]  
BRUGGHE J, 1995, P PATH SOC GREAT BRI
[5]  
FLEEGE JC, 1993, ANAL QUANT CYTOL, V15, P281
[6]   ANALYSIS OF MEASURING SYSTEM PARAMETERS THAT INFLUENCE REPRODUCIBILITY OF MORPHOMETRIC ASSESSMENTS WITH A GRAPHIC TABLET [J].
FLEEGE, JC ;
BAAK, JPA ;
SMEULDERS, AWM .
HUMAN PATHOLOGY, 1988, 19 (05) :513-517
[7]  
FLEEGE JC, 1990, LAB INVEST, V63, P270
[8]   PROLIFERATING CELL NUCLEAR ANTIGEN IN THE ASSESSMENT OF BARRETTS MUCOSA [J].
GILLEN, P ;
MCDERMOTT, M ;
GREHAN, D ;
HOURIHANE, DO ;
HENNESSY, TPJ .
BRITISH JOURNAL OF SURGERY, 1994, 81 (12) :1766-1768
[9]   EPITHELIAL PROLIFERATION IN BARRETT-ESOPHAGUS BY PROLIFERATING CELL NUCLEAR ANTIGEN IMMUNOLOCALIZATION [J].
GRAY, MR ;
HALL, PA ;
NASH, J ;
ANSARI, B ;
LANE, DP ;
KINGSNORTH, AN .
GASTROENTEROLOGY, 1992, 103 (06) :1769-1776
[10]   THE EFFICIENCY OF SYSTEMATIC-SAMPLING IN STEREOLOGY AND ITS PREDICTION [J].
GUNDERSEN, HJG ;
JENSEN, EB .
JOURNAL OF MICROSCOPY-OXFORD, 1987, 147 :229-263