Three-dimensional recording of the human face with a 3D laser scanner

被引:83
作者
Kovacs, L.
Zimmermann, A.
Brockmann, G.
Guehring, M.
Baurecht, H.
Papadopulos, N. A.
Schwenzer-Zimmerer, K.
Sader, R.
Biemer, E.
Zeilhofer, H. F.
机构
[1] Tech Univ Munich, Dept Plast & Reconstruct Surg, Klinikum Rechts Isar, D-81675 Munich, Germany
[2] Tech Univ Munich, Inst Med Stat & Epidemiol, Klinikum Rechts Isar, D-81675 Munich, Germany
[3] Tech Univ Munich, Ctr Adv Studies Cranio Maxillo Facial Surg, Klinikum Rechts Isar, D-81675 Munich, Germany
[4] Univ Basel, Div Cranio Maxillo Facial Surg, Dept Reconstruct Surg, CH-4031 Basel, Switzerland
[5] Univ Frankfurt, Dept Cranio Maxillofacial & Facial Plast Surg, D-60590 Frankfurt, Germany
关键词
non-contact laser scanner; three-dimensional imaging; human face; accuracy; precision; 3D shape measurement;
D O I
10.1016/j.bjps.2005.10.025
中图分类号
R61 [外科手术学];
学科分类号
摘要
Three-dimensional recording of the surface of the human body or of certain anatomical areas has gained an ever increasing importance in recent years. When recording living surfaces, such as the human face, not only has a varying degree of surface complexity to be accounted for, but also a variety of other factors, such as motion artefacts. It is of importance to establish standards for the recording procedure, which will optimise results and allow for better comparison and validation. In the study presented here, the faces of five mate test persons were scanned in different experimental. settings using non-contact 3D digitisers, type Minotta Vivid 910((R)). Among others, the influence of the number of scanners used, the angle of recording, the head position of the test person, the impact of the examiner and of examination time on accuracy and precision of the virtual face models generated from the scanner data with specialised software were investigated. Computed data derived from the virtual. models were compared to corresponding reference measurements carried out manually between defined Landmarks on the test persons' faces.
引用
收藏
页码:1193 / 1202
页数:10
相关论文
共 16 条
[1]   EVALUATION OF THE LASER SCANNER AS A SURFACE MEASURING TOOL AND ITS ACCURACY COMPARED WITH DIRECT FACIAL ANTHROPOMETRIC MEASUREMENTS [J].
AUNG, SC ;
NGIM, RCK ;
LEE, ST .
BRITISH JOURNAL OF PLASTIC SURGERY, 1995, 48 (08) :551-558
[2]   Three dimensional laser scan assessment of the Oriental nose with a new classification of Oriental nasal types [J].
Aung, SC ;
Foo, CL ;
Lee, ST .
BRITISH JOURNAL OF PLASTIC SURGERY, 2000, 53 (02) :109-116
[3]   QUANTIFICATION OF FACIAL SURFACE CHANGE USING A STRUCTURED LIGHT SCANNER [J].
BHATIA, G ;
VANNIER, MW ;
SMITH, KE ;
COMMEAN, PK ;
RIOLO, J ;
YOUNG, VL .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1994, 94 (06) :768-774
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   Living human face measurements using pulsed holography [J].
Bongartz, J ;
Giel, D ;
Hering, P .
HOLOGRAPHY 2000, 2000, 4149 :303-308
[6]   Three-dimensional facial anthropometry using a laser surface scanner: Validation of the technique [J].
Bush, K ;
Antonyshyn, O .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1996, 98 (02) :226-235
[7]   3-DIMENSIONAL INPUT OF BODY-SURFACE DATA USING A LASER-LIGHT SCANNER [J].
CUTTING, CB ;
MCCARTHY, JG ;
KARRON, DB .
ANNALS OF PLASTIC SURGERY, 1988, 21 (01) :38-45
[8]  
ENCISO R, 2003, 3D HEAD ANTHROPOMETR
[9]  
Farkas LG, 1986, ANTHROPOMETRIC FACIA
[10]   A three-dimensional computerized mesh diagram analysis and its application in soft tissue facial morphometry [J].
Ferrario, VF ;
Sforza, C ;
Schmitz, JH ;
Miani, A ;
Serrao, G .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1998, 114 (04) :404-413