Acetabular Revision Surgery with Tantalum Trabecular Metal Acetabular Cup for Failed Acetabular Cage Reconstruction with Bone Allografts: A Retrospective Study with Mid- to Long-Term Follow-Up

被引:4
作者
Hsu, Chen-Heng [1 ,2 ]
Hu, Chih-Chien [1 ,2 ,3 ]
Chang, Chih-Hsiang [1 ,2 ,3 ]
Chang, Yu-Han [1 ,2 ,3 ]
Shih, Hsin-Nung [1 ,2 ,3 ]
Chen, Chun-Chieh [1 ,2 ,3 ]
机构
[1] Chang Gung Mem Hosp, Dept Orthoped Surg, Taoyuan, Taiwan
[2] Chang Gung Mem Hosp, Bone & Joint Res Ctr, Taoyuan 33305, Taiwan
[3] Chang Gung Univ, Coll Med, Taoyuan 33302, Taiwan
关键词
tantalum trabecular metal acetabular cup; failed cage reconstruction; revision hip arthroplasty; TOTAL HIP-ARTHROPLASTY; DEFECTS; CLASSIFICATION; TERIPARATIDE; GRAFTS; RING;
D O I
10.3390/jcm11123428
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Acetabular cage reconstruction with bone allografts is among the successful strategies to deal with massive acetabular bone loss. However, the nonbiological fixation nature of cages can compromise long-term success. Tantalum trabecular metal acetabular cups (TM cups) have been used in acetabular revision surgery because of their increased initial stability and good bone ingrowth features. This study was performed to determine whether the bone stock of the acetabulum is enough to support a hemispheric TM cup after failed cage reconstruction with bone allografts. Methods: We retrospectively reviewed patients who received acetabular revision surgery with TM cups after failed cage reconstruction with bone allografts from 2006 to 2017. There were 12 patients (5 males and 7 females) included in this study, with a mean age of 61.5 years (38 to 81) at the time of re-revision surgery. The mean follow-up after re-revision surgery was 8.6 years (2.6 to 13.3). The endpoint was defined as the aseptic loosening of the TM cup and reoperation for any causes. The change in bone stock of the acetabulum between index revision and re-revision was assessed according to the Gross classification for acetabular bone loss. Results: One patient died after eight years of follow-up of a cause not related to hip surgery. Two patients received two-stage revision arthroplasty due to PJI after 3.2 and 9.4 years of follow-up, respectively. The bone stock of the acetabulum was significantly improved between index revision and re-revision surgery (p < 0.0001). The Kaplan-Meier survivorship was 100% with aseptic loosening as the endpoint and 90% and 75% at five- and ten-year follow-up, respectively, with reoperation for any reason as the endpoint. Even cage reconstruction with bone allografts will fail eventually, and the bone stock of the acetabulum will improve after union and incorporation between host bone and allografts. The restored bone stocks will facilitate further revision surgery with hemispheric TM cups. The biological fixation between host bone and tantalum trabecular metal can provide longstanding stability of the TM cup. Conclusions: The results of our study offer a viable option for patients with failed cage reconstruction with bone allografts.
引用
收藏
页数:9
相关论文
共 50 条
[41]   Revision Total Hip Arthroplasty Utilizing an Acetabular Reinforcement Ring with a Metal Augment: A Minimum Eight-Year Follow-Up Study [J].
Kim, Han Soul ;
Kim, Ji Wan ;
Chang, Jae Suk ;
Kim, Chul-Ho .
MEDICINA-LITHUANIA, 2023, 59 (06)
[42]   Clinical and radiographic outcomes of acetabular impaction grafting without cage reinforcement for revision hip replacement A MINIMUM TEN-YEAR FOLLOW-UP STUDY [J].
Gilbody, J. ;
Taylor, C. ;
Bartlett, G. E. ;
Whitehouse, S. L. ;
Hubble, M. J. W. ;
Timperley, A. J. ;
Howell, J. R. ;
Wilson, M. J. .
BONE & JOINT JOURNAL, 2014, 96B (02) :188-194
[43]   Long-Term Clinical and Radiographic Outcomes of Porous Tantalum Monoblock Acetabular Component in Primary Hip Arthroplasty: A Minimum of 15-Year Follow-Up [J].
De Martino, Ivan ;
De Santis, Vincenzo ;
Sculco, Peter K. ;
D'Apolito, Rocco ;
Poultsides, Lazaros A. ;
Gasparini, Giorgio .
JOURNAL OF ARTHROPLASTY, 2016, 31 (09) :S110-S114
[44]   Acetabular reconstruction using a composite layer of impacted cancellous allograft bone and cement: minimum 5-year follow-up study [J].
Garala, Kanai ;
Boutefnouchet, Tarek ;
Amblawaner, Rishanthanan ;
Lawrence, Trevor .
HIP INTERNATIONAL, 2022, 32 (02) :197-204
[45]   Long-term follow-up of a low profile, coated, press-fit cup: the trabeculae oriented pattern (T.O.P.) acetabular system [J].
L. Mosconi ;
L. Cavagnaro ;
A. Zanirato ;
E. Quarto ;
M. Lontaro Baracchini ;
M. Formica .
European Journal of Orthopaedic Surgery & Traumatology, 2021, 31 :1515-1521
[46]   Major acetabular defects treated with the Burch-Schneider antiprotrusion cage and impaction bone allograft in a large series: a 5-to 7-year follow-up study [J].
Marx, Axel ;
Beier, Alexander ;
Richter, Anne ;
Lohmann, Christoph H. ;
Halder, Andreas M. .
HIP INTERNATIONAL, 2016, 26 (06) :585-590
[47]   Long-term results of the uncemented acetabular component in a primary total hip arthroplasty performed for protrusio acetabuli: a fifteen year median follow-up [J].
Baghdadi, Yaser M. K. ;
Larson, A. Noelle ;
Sierra, Rafael J. .
INTERNATIONAL ORTHOPAEDICS, 2015, 39 (05) :839-845
[48]   Robotic arm-assisted acetabular reconstruction in revision total hip arthroplasty A CLINICAL STUDY WITH MINIMUM TWO-YEAR FOLLOW-UP [J].
Deng, W. ;
Wu, X. ;
Shao, H. ;
Tang, H. ;
Huang, Y. ;
Wang, Z. ;
Yang, D. ;
Zhou, Y. .
BONE & JOINT JOURNAL, 2025, 107B (04) :404-412
[49]   The use of bilobed porous-coated acetabular components without structural bone graft for type III acetabular defects in revision total hip arthroplasty - A prospective study with a minimum 2-year follow-up [J].
Moskal, JT ;
Shen, FH .
JOURNAL OF ARTHROPLASTY, 2004, 19 (07) :867-873
[50]   Acetabular Reconstruction Using a Kerboull Cross-Plate, Structural Allograft and Cemented Dual-Mobility Cup in Revision THA at a Minimum 5-Year Follow-Up [J].
Wegrzyn, Julien ;
Pibarot, Vincent ;
Jacquel, Alexandre ;
Carret, Jean-Paul ;
Bejui-Hugues, Jacques ;
Guyen, Olivier .
JOURNAL OF ARTHROPLASTY, 2014, 29 (02) :432-437