Acetabular Revision Surgery with Tantalum Trabecular Metal Acetabular Cup for Failed Acetabular Cage Reconstruction with Bone Allografts: A Retrospective Study with Mid- to Long-Term Follow-Up

被引:4
作者
Hsu, Chen-Heng [1 ,2 ]
Hu, Chih-Chien [1 ,2 ,3 ]
Chang, Chih-Hsiang [1 ,2 ,3 ]
Chang, Yu-Han [1 ,2 ,3 ]
Shih, Hsin-Nung [1 ,2 ,3 ]
Chen, Chun-Chieh [1 ,2 ,3 ]
机构
[1] Chang Gung Mem Hosp, Dept Orthoped Surg, Taoyuan, Taiwan
[2] Chang Gung Mem Hosp, Bone & Joint Res Ctr, Taoyuan 33305, Taiwan
[3] Chang Gung Univ, Coll Med, Taoyuan 33302, Taiwan
关键词
tantalum trabecular metal acetabular cup; failed cage reconstruction; revision hip arthroplasty; TOTAL HIP-ARTHROPLASTY; DEFECTS; CLASSIFICATION; TERIPARATIDE; GRAFTS; RING;
D O I
10.3390/jcm11123428
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Acetabular cage reconstruction with bone allografts is among the successful strategies to deal with massive acetabular bone loss. However, the nonbiological fixation nature of cages can compromise long-term success. Tantalum trabecular metal acetabular cups (TM cups) have been used in acetabular revision surgery because of their increased initial stability and good bone ingrowth features. This study was performed to determine whether the bone stock of the acetabulum is enough to support a hemispheric TM cup after failed cage reconstruction with bone allografts. Methods: We retrospectively reviewed patients who received acetabular revision surgery with TM cups after failed cage reconstruction with bone allografts from 2006 to 2017. There were 12 patients (5 males and 7 females) included in this study, with a mean age of 61.5 years (38 to 81) at the time of re-revision surgery. The mean follow-up after re-revision surgery was 8.6 years (2.6 to 13.3). The endpoint was defined as the aseptic loosening of the TM cup and reoperation for any causes. The change in bone stock of the acetabulum between index revision and re-revision was assessed according to the Gross classification for acetabular bone loss. Results: One patient died after eight years of follow-up of a cause not related to hip surgery. Two patients received two-stage revision arthroplasty due to PJI after 3.2 and 9.4 years of follow-up, respectively. The bone stock of the acetabulum was significantly improved between index revision and re-revision surgery (p < 0.0001). The Kaplan-Meier survivorship was 100% with aseptic loosening as the endpoint and 90% and 75% at five- and ten-year follow-up, respectively, with reoperation for any reason as the endpoint. Even cage reconstruction with bone allografts will fail eventually, and the bone stock of the acetabulum will improve after union and incorporation between host bone and allografts. The restored bone stocks will facilitate further revision surgery with hemispheric TM cups. The biological fixation between host bone and tantalum trabecular metal can provide longstanding stability of the TM cup. Conclusions: The results of our study offer a viable option for patients with failed cage reconstruction with bone allografts.
引用
收藏
页数:9
相关论文
共 50 条
[31]   Reconstruction of acetabular defects with porous tantalum shells and augments in revision total hip arthroplasty at ten-year follow-up [J].
Loechel, J. ;
Janz, V ;
Hipfl, C. ;
Perka, C. ;
Wassilew, G., I .
BONE & JOINT JOURNAL, 2019, 101B (03) :311-316
[32]   Burch-Schneider antiprotrusio cage for acetabular revision: a 5-to 13-year follow-up study [J].
Coscujuela-Mana, Antonio ;
Angles, Francesc ;
Tramunt, Carles ;
Casanova, Xavier .
HIP INTERNATIONAL, 2010, 20 :S112-S118
[33]   Bone-graft augmentation for acetabular deficiencies in total hip arthroplasty - Results of long-term follow-up evaluation [J].
Lee, BP ;
Cabanela, ME ;
Wallrichs, SL ;
Ilstrup, DM .
JOURNAL OF ARTHROPLASTY, 1997, 12 (05) :503-510
[34]   Mid-term results of revision surgery using double-trabecular metal cups alone or combined with impaction bone grafting for complex acetabular defects [J].
Xianghong Zhang ;
Zhihong Li ;
Wanchun Wang ;
Tang Liu ;
Weiqiu Peng .
Journal of Orthopaedic Surgery and Research, 15
[35]   Long-term follow-up of a low profile, coated, press-fit cup: the trabeculae oriented pattern (TOP) acetabular system [J].
Mosconi, L. ;
Cavagnaro, L. ;
Zanirato, A. ;
Quarto, E. ;
Lontaro Baracchini, M. ;
Formica, M. .
EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2021, 31 (07) :1515-1521
[36]   Acetabular fracture: Long-term follow-up and factors associated with secondary implantation of total hip arthroplasty [J].
Dunet, B. ;
Tournier, C. ;
Billaud, A. ;
Lavoinne, N. ;
Fabre, T. ;
Durandeau, A. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2013, 99 (03) :281-290
[37]   Excellent long-term results of the Muller acetabular reinforcement ring in primary cup revision A single-center study of 259 cases after a mean of 10 years' follow-up [J].
Mueller Greber, Pascal ;
Manzoni, Isabella ;
Ochsner, Peter E. ;
Ilchmann, Thomas ;
Zwicky, Lukas ;
Clauss, Martin .
ACTA ORTHOPAEDICA, 2017, 88 (06) :619-626
[38]   Acute Total Hip Arthroplasty in Acetabular Fractures in the Elderly Using the Octopus System Mid Term to Long Term Follow-Up [J].
Malhotra, Rajesh ;
Singh, Davinder Pal ;
Jain, Vaibhav ;
Kumar, Vijay ;
Singh, Ravijot .
JOURNAL OF ARTHROPLASTY, 2013, 28 (06) :1005-1009
[39]   Mid-Term to Long-Term Results of Revision Total Hip Arthroplasty Using the Oval-Shaped Acetabular Cup - TC Type [J].
Stastny, E. ;
Trc, T. ;
Frydl, J. ;
Kopecny, Z. ;
Philippou, T. ;
Lisy, J. .
ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2017, 84 (04) :271-278
[40]   Treatment of Severe Acetabular Defects With an Antiprotrusio Cage and Trabecular Metal Augments - Clinical and Radiographic Results After a Mean Follow-Up of 6.6 Years [J].
Bellova, Petri ;
Reich, Marie-Christin ;
Grothe, Tim ;
Guenther, Klaus-Peter ;
Stiehler, Maik ;
Goronzy, Jens .
JOURNAL OF ARTHROPLASTY, 2023, 38 (11) :2415-2422