Measurement of the weighted peak level for occupational exposure to gradient magnetic fields for 1.5 and 3 Tesla MRI body scanners

被引:5
作者
Bonutti, F. [1 ]
Tecchio, M. [2 ]
Maieron, M. [1 ]
Trevisan, D. [3 ]
Negro, C. [4 ]
Calligaris, F. [5 ]
机构
[1] Acad Hosp S Maria della Misericordia, Dept Med Phys, Udine, Italy
[2] Univ Udine, Sch Radiographers, Fac Med, I-33100 Udine, Italy
[3] APSS Trento, S Chiara Hosp, Dept Med Phys, Trento, Italy
[4] Univ Trieste, Dept Occupat Med, Trieste, Italy
[5] Univ Trieste, Dept Phys, Trieste, Italy
关键词
WORKERS;
D O I
10.1093/rpd/ncv308
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The purpose of this work is to give a contribution to the construction of a comprehensive knowledge of the exposure levels to gradient magnetic fields (GMF) in terms of the weighed peak (WP), especially for 3 Tesla scanners for which there are still few works available in the literature. A new generation probe for the measurement of electromagnetic fields in the range of 1 Hz-400 kHz was used to assess the occupational exposure levels to the GMF for 1.5 and 3.0 Tesla MRI body scanners, using the method of the WP according to the International Commission on Non-Ionizing Radiation Protection (ICNIRP) approach. The probe was placed at a height of 1.1 m, close to the MRI scanners, where operators could stay during some medical procedures with particular issues. The measurements were performed for a set of typical acquisition sequences for body (liver) and head exams. The measured values of WP were in compliance with ICNIRP 2010 reference levels for occupational exposures.
引用
收藏
页码:358 / 364
页数:7
相关论文
共 12 条
[1]  
Ahlbom A, 1998, HEALTH PHYS, V74, P494
[2]   Weighted-peak assessment of occupational exposure due to MRI gradient fields and movements in a nonhomogeneous static magnetic field [J].
Andreuccetti, D. ;
Contessa, G. M. ;
Falsaperla, R. ;
Lodato, R. ;
Pinto, R. ;
Zoppetti, N. ;
Rossi, P. .
MEDICAL PHYSICS, 2013, 40 (01)
[3]   Occupational exposure to static and time-varying gradient magnetic fields in MR units [J].
Bradley, Jill K. ;
Nyekiova, Matilda ;
Price, David L. ;
Lopez, Lindsay D'jon ;
Crawley, Therese .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (05) :1204-1209
[4]  
Capstick M, 2008, VT2007017 EUR COMM E
[5]   Exposure of workers to pulsed gradients in MRI [J].
Crozier, Stuart ;
Wang, Hua ;
Trakic, Adnan ;
Liu, Feng .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (05) :1236-1254
[6]   Personal Exposure to Static and Time-Varying Magnetic Fields During MRI System Test Procedures [J].
de Vocht, Frank ;
Muller, Floris ;
Engels, Hans ;
Kromhout, Hans .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (05) :1223-1228
[7]   Analysis and measurements of magnetic field exposures for healthcare workers in selected MR environments [J].
Fuentes, Miguel A. ;
Trakic, Adnan ;
Wilson, Stephen J. ;
Crozier, Stuart .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2008, 55 (04) :1355-1364
[8]   ICNIRP STATEMENT-GUIDELINES FOR LIMITING EXPOSURE TO TIME-VARYING ELECTRIC AND MAGNETIC FIELDS (1 HZ TO 100 KHZ) [J].
不详 .
HEALTH PHYSICS, 2010, 99 (06) :818-836
[9]   Occupational exposure measurements of static and pulsed gradient magnetic fields in the vicinity of MRI scanners [J].
Kannala, Sami ;
Toivo, Tim ;
Alanko, Tommi ;
Jokela, Kari .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (07) :2243-2257
[10]   Numerically-simulated induced electric field and current density within a human model located close to a z-gradient coil [J].
Li, Yan ;
Hand, Jeff W. ;
Wills, Tim ;
Hajnal, Jo V. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (05) :1286-1295