Validation by collaborative trial of an isotope dilution liquid chromatographic tandem mass spectrometric method to determine the content of acrylamide in roasted coffee

被引:12
|
作者
Wenzl, T. [1 ]
Szilagyi, S. [1 ]
Rosen, J. [2 ]
Karasek, L. [1 ]
机构
[1] Commiss European Communities, Joint Res Ctr, Inst Reference Mat & Measurements, B-2440 Geel, Belgium
[2] Swedish Natl Food Adm, Chem Div 1, S-75126 Uppsala, Sweden
来源
FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT | 2009年 / 26卷 / 08期
关键词
chromatography; inter-laboratory validation; liquid chromatography/mass spectrometry (LC/MS); acrylamide; coffee; FOOD;
D O I
10.1080/02652030902939689
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
A method for the determination of acrylamide in roasted coffee was subjected to method validation by collaborative trial. The aim was to extend the scope of a method already standardized for the determination of acrylamide in bakery and potato products to include roasted coffee. Modifications of the already standardized method were therefore kept to a minimum. The method was based on aqueous extraction of the roasted coffee matrix and solid-phase extraction (SPE) clean-up followed by isotope dilution high-performance liquid chromatography with tandem mass spectrometric detection (LC-MS/MS). The test portion of the sample was spiked with stable isotope-labelled acrylamide and extracted on a mechanical shaker with n-hexane and water for 1 h. The sample extract was centrifuged, the organic phase discarded, and a portion of the aqueous extract further cleaned-up by SPE on an Isolute Multimode cartridge followed by a second clean-up step on an Isolute ENV+cartridge. The volume of the acrylamide-containing fraction eluted from the second SPE column was reduced by evaporation and analysed by LC-MS/MS. Three coffee samples and one aqueous acrylamide standard solution were sent to eleven laboratories from eight European Union Member States. All samples were sent as blind duplicates. Based on the reported results, the relative standard deviations for reproducibility (RSDR) were 11.5% at a level of 160 mu g kg(-1), 10.1% at a level of 263 mu g kg(-1), and 9.6% at a level of 585 mu g kg(-1). The values for repeatability (RSDr) in those materials ranged from 1.0% to 3.5%. The method performance parameters satisfied internationally accepted criteria. Hence, the method would be suitable for the enforcement of regulatory limits.
引用
收藏
页码:1146 / 1152
页数:7
相关论文
共 36 条