Experimental analysis of R410A flow in helically rib-roughened tubes

被引:4
|
作者
do Nascimento, Carlos Richter [1 ]
Mariani, Viviana Cocco [1 ,2 ]
Coelho, Leandro dos Santos [2 ,3 ]
机构
[1] Pontifical Catholic Univ Parana PUCPR, Mech Engn Grad Program PPGEM, 1155 Rua Imaculada Conceicao, BR-80215901 Curitiba, Parana, Brazil
[2] Fed Univ Parana UFPR, Dept Elect Engn, 100 Ave Coronel Francisco Heraclito dos Santos, BR-81530000 Curitiba, Parana, Brazil
[3] Pontifical Catholic Univ Parana PUCPR, Ind & Syst Engn Grad Program PPGEPS, 1155 Rua Imaculada Conceicao, BR-80215901 Curitiba, Parana, Brazil
关键词
Enhanced surfaces; Rib-roughened tubes; R410A; Forced convection; Heat exchangers; Friction factor; Heat transfer coefficient; HEAT-TRANSFER CHARACTERISTICS; MICRO-FIN TUBES; FOULING CHARACTERISTICS; HORIZONTAL SMOOTH; PRESSURE-DROP; REFRIGERANTS; FRICTION; MIXTURE; PERFORMANCE; ROUGHNESS;
D O I
10.1016/j.tsep.2020.100668
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this study, an experimental setup was built to investigate the two-phase flow characteristics of R410A refrigerant fluid inside a horizontal internally micro-fin helical coiled tube made of copper. The experimental measurements are carried out with a fixed refrigerant fluid evaporation with temperature equals to 10 degrees C for eleven mass fluxes values varied from 0.00635 (kg/s) to 0.02150 (kg/s), and the Reynolds number ranged from 6998 to 23,695 covering turbulent flow regime. The heat flux supplied to the micro finned test section was fixed in 10 (kW/m(2)) and mixture quality at 30% of the vapor phase. The experimental results were accurately measured under the diabatic condition. Friction factor and heat transfer coefficient were obtained experimentally and compared with available literature correlations for smooth and finned tube configurations. Results showed that the presence of internal helical-rib roughness increased friction factor by 27% when compared with a smooth wall, and 5.3% when compared with finned tubes correlation. New correlation to predict the friction factor of R410A refrigerant fluid inside the micro-fin helical coiled tube was developed based on flow patterns and it agrees with experiment data within the deviation of +/- 0.4%. The heat transfer coefficient shows a minimum average deviation of 10.5% when compared with literature.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] CONVECTIVE CONDENSATION OF R410A IN MICRO-FIN TUBES
    Zhang, Guan-min
    Wu, Zan
    Wang, Xu
    Li, Wei
    JOURNAL OF ENHANCED HEAT TRANSFER, 2012, 19 (06) : 515 - 525
  • [42] Experimental and numerical investigation of impingement on a rib-roughened leading-edge wall
    Taslim, M
    Bakhtari, K
    Liu, H
    JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2003, 125 (04): : 682 - 691
  • [43] Experimental investigation of the aerothermal performance of a high blockage rib-roughened cooling channel
    Casarsa, L
    Arts, T
    JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2005, 127 (03): : 580 - 588
  • [44] Experimental investigation of impingement heat transfer from a round rib-roughened surface
    Mustafa Kemal Isman
    Muhiddin Can
    Heat and Mass Transfer, 2017, 53 : 1405 - 1412
  • [45] Direct numerical simulations of turbulent channel flow with a rib-roughened porous wall
    Suga, Kazuhiko
    Kuwata, Yusuke
    JOURNAL OF FLUID MECHANICS, 2024, 980
  • [46] Numerical study of turbulent flow through rib-roughened channels with mist injection
    Elwekeel, Fifi N. M.
    Zheng, Qun
    Abdala, Antar M. M.
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2014, VOL 5A, 2014,
  • [47] Effects of bleed flow on heat/mass transfer in a rotating rib-roughened channel
    Jeon, Yun Heung
    Park, Suk Hwan
    Kim, Kyung Min
    Lee, Dong Hyun
    Cho, Hyung Hee
    PROCEEDINGS OF THE ASME TURBO EXPO 2006, VOL 3, PTS A AND B: HEAT TRANSFER: GENERAL INTEREST, 2006, : 877 - 885
  • [48] An experimental investigation of the rib surface-averaged heat transfer coefficient in a rib-roughened square passage
    Taslim, ME
    Wadsworth, CM
    JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 1997, 119 (02): : 381 - 389
  • [49] Visualization of R410A Flow Boiling Inside Horizontal Smooth Tubes under Diabatic Conditions
    Yang, Cheng-Min
    Hrnjak, Pega
    HEAT TRANSFER ENGINEERING, 2021, 42 (15) : 1237 - 1248
  • [50] Prediction of turbulent flow structure in a fully developed rib-roughened narrow rectangular channel
    Md. Shafiqul Islam
    M. Kaminaga
    R. Hino
    M. Monde
    Journal of Thermal Science, 2009, 18 : 126 - 136