Experimental analysis of R410A flow in helically rib-roughened tubes

被引:4
|
作者
do Nascimento, Carlos Richter [1 ]
Mariani, Viviana Cocco [1 ,2 ]
Coelho, Leandro dos Santos [2 ,3 ]
机构
[1] Pontifical Catholic Univ Parana PUCPR, Mech Engn Grad Program PPGEM, 1155 Rua Imaculada Conceicao, BR-80215901 Curitiba, Parana, Brazil
[2] Fed Univ Parana UFPR, Dept Elect Engn, 100 Ave Coronel Francisco Heraclito dos Santos, BR-81530000 Curitiba, Parana, Brazil
[3] Pontifical Catholic Univ Parana PUCPR, Ind & Syst Engn Grad Program PPGEPS, 1155 Rua Imaculada Conceicao, BR-80215901 Curitiba, Parana, Brazil
关键词
Enhanced surfaces; Rib-roughened tubes; R410A; Forced convection; Heat exchangers; Friction factor; Heat transfer coefficient; HEAT-TRANSFER CHARACTERISTICS; MICRO-FIN TUBES; FOULING CHARACTERISTICS; HORIZONTAL SMOOTH; PRESSURE-DROP; REFRIGERANTS; FRICTION; MIXTURE; PERFORMANCE; ROUGHNESS;
D O I
10.1016/j.tsep.2020.100668
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this study, an experimental setup was built to investigate the two-phase flow characteristics of R410A refrigerant fluid inside a horizontal internally micro-fin helical coiled tube made of copper. The experimental measurements are carried out with a fixed refrigerant fluid evaporation with temperature equals to 10 degrees C for eleven mass fluxes values varied from 0.00635 (kg/s) to 0.02150 (kg/s), and the Reynolds number ranged from 6998 to 23,695 covering turbulent flow regime. The heat flux supplied to the micro finned test section was fixed in 10 (kW/m(2)) and mixture quality at 30% of the vapor phase. The experimental results were accurately measured under the diabatic condition. Friction factor and heat transfer coefficient were obtained experimentally and compared with available literature correlations for smooth and finned tube configurations. Results showed that the presence of internal helical-rib roughness increased friction factor by 27% when compared with a smooth wall, and 5.3% when compared with finned tubes correlation. New correlation to predict the friction factor of R410A refrigerant fluid inside the micro-fin helical coiled tube was developed based on flow patterns and it agrees with experiment data within the deviation of +/- 0.4%. The heat transfer coefficient shows a minimum average deviation of 10.5% when compared with literature.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] FORCED-CONVECTION HEAT-TRANSFER IN HELICALLY RIB-ROUGHENED TUBES
    GEE, DL
    WEBB, RL
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1980, 23 (08) : 1127 - 1136
  • [2] An experimental study of a rib-roughened rotating U-bend flow
    Iacovides, H
    Jackson, DC
    Launder, BE
    Yuan, YM
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 1999, 19 (03) : 151 - 159
  • [3] Experimental study of flow and heat transfer in rib-roughened rectangular channels
    Olsson, CO
    Sunden, B
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 1998, 16 (04) : 349 - 365
  • [4] Experimental analysis of turbulent flow structure in a fully developed rib-roughened rectangular channel with PIV
    Shafiqul M. Islam
    K. Haga
    M. Kaminaga
    R. Hino
    M. Monde
    Experiments in Fluids, 2002, 33 : 296 - 306
  • [5] Experimental analysis of turbulent flow structure in a fully developed rib-roughened rectangular channel with PIV
    Islam, MS
    Haga, K
    Kaminaga, M
    Hino, R
    Monde, M
    EXPERIMENTS IN FLUIDS, 2002, 33 (02) : 296 - 306
  • [6] Numerical simulation of channel flow with a rib-roughened wall
    Miyake, Y
    Tsujimoto, K
    Nagai, N
    JOURNAL OF TURBULENCE, 2002, 3
  • [7] The effect of gravity on R410A condensing flow in horizontal circular tubes
    Li, Wei
    Zhang, Jingzhi
    Mi, Pengfei
    Zhao, Jianfu
    Tao, Zhi
    Childs, Peter R. N.
    Shih, Tom I. -P.
    NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2017, 71 (03) : 327 - 340
  • [8] HYBRID RANS/LES OF FLOW IN A RIB-ROUGHENED ROTATING CHANNEL
    Kubacki, Slawomir
    Rokicki, Jacek
    Dick, Erik
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2014, VOL 5A, 2014,
  • [9] Reynolds number effects in rib-roughened turbulent channel flow
    Jagadeesan, Karthikeyan
    Narasimhamurthy, Vagesh D.
    INTERNATIONAL JOURNAL OF ADVANCES IN ENGINEERING SCIENCES AND APPLIED MATHEMATICS, 2019, 11 (04) : 254 - 262
  • [10] Reynolds number effects in rib-roughened turbulent channel flow
    Karthikeyan Jagadeesan
    Vagesh D. Narasimhamurthy
    International Journal of Advances in Engineering Sciences and Applied Mathematics, 2019, 11 : 254 - 262