Fullerene C60 modified gold electrode and nanogold modified indium tin oxide electrode for prednisolone determination

被引:29
作者
Goyal, Rajendra N. [1 ]
Oyama, Munetaka [2 ]
Bachheti, Neeta [1 ]
Singh, Sudhanshu P. [1 ]
机构
[1] Indian Inst Technol, Dept Chem, Roorkee 247667, Uttar Pradesh, India
[2] Kyoto Univ, Grad Sch Engn, Nishikyo Ku, Kyoto 6158520, Japan
关键词
Prednisolone; Nanogold modified indium tin oxide electrode; Voltammetry; Fullerene; PULSE VOLTAMMETRIC DETERMINATION; URINE; EXTRACTION; BLOOD; CORTICOSTEROIDS; CHROMATOGRAPHY; CORTISOL; ATENOLOL; PLASMA; SERUM;
D O I
10.1016/j.bioelechem.2008.10.001
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The electrochemical determination of prednisolone has been investigated at fullerene-C-60-modified gold (C-60/Au) electrode and gold nanoparticles modified indium tin oxide (nano Au/ITO) electrode in phosphate buffer solution (PBS) of pH 7.2. During oxidation of prednisolone. an anodic peak with peak potential (E-p) at 570 mV and 400 mV appeared at nano Au/ITO and C-60/Au electrode, respectively. The experimental results revealed that gold nanoparticles as well as fullerene (C-60) promote the rate of prednisolone oxidation by increasing the peak current (i(p)) and oxidizing at lower peak potentials as compared to the respective bare electrodes due to their electrocatalytic effect. The linear concentration range at both the electrodes was in the range of 1 mu M to 0.10 mM. The detection limit obtained at C-60/Au electrode was 26 nM. while at nano Au/ITO electrode the detection limit was 90 nM. The applicability of the method to direct assays of human urine and whole blood sample is described to use the method for testing cases of doping by athletes. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:272 / 277
页数:6
相关论文
共 30 条
[1]   Simple liquid chromatography method for the rapid simultaneous determination of prednisolone and cortisol in plasma and urine using hydrophilic lipophilic balanced solid phase extraction cartridges [J].
AbuRuz, S ;
Millership, J ;
Heaney, L ;
McElnay, J .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 798 (02) :193-201
[2]   An improved synthesis of high-aspect-ratio gold nanorods [J].
Busbee, BD ;
Obare, SO ;
Murphy, CJ .
ADVANCED MATERIALS, 2003, 15 (05) :414-+
[3]  
Christian G.D., 1962, JELECTROANAL CHEM, V3, P363
[4]  
European Commission, 2001, 2 EUR AG EV MED PROD, P1
[5]   Determination of prednisolone and prednisone in plasma, whole blood, urine, and bound-to-plasma proteins by high-performance liquid chromatography [J].
Gai, MN ;
Pinilla, E ;
Paulos, C ;
Chávez, J ;
Puelles, V ;
Arancibia, A .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2005, 43 (04) :201-206
[6]   Differential pulse voltammetric determination of methylprednilsolone in pharmaceuticals and human biological fluids [J].
Goyal, Rajendra N. ;
Bachheti, Neeta ;
Tyagi, Anuradha ;
Pandey, Ashish K. .
ANALYTICA CHIMICA ACTA, 2007, 605 (01) :34-40
[7]   Voltammetric determination of atenolol at C60-modified glassy carbon electrodes [J].
Goyal, Rajendra N. ;
Singh, Sudhanshu P. .
TALANTA, 2006, 69 (04) :932-937
[8]   Differential pulse voltammetric determination of atenolol in pharmaceutical formulations and urine using nanogold modified indium tin oxide electrode [J].
Goyal, RN ;
Gupta, VK ;
Oyama, M ;
Bachheti, N .
ELECTROCHEMISTRY COMMUNICATIONS, 2006, 8 (01) :65-70
[9]   Blood basophil numbers in chronic ordinary urticaria and healthy controls: diurnal variation, influence of loratadine and prednisolone and relationship to disease activity [J].
Grattan, CEH ;
Dawn, G ;
Gibbs, S ;
Francis, DM .
CLINICAL AND EXPERIMENTAL ALLERGY, 2003, 33 (03) :337-341
[10]  
Hafström I, 2007, J RHEUMATOL, V34, P1810