Navigated Long-Bone Fracture Reduction

被引:16
作者
Kahler, David M. [1 ]
机构
[1] Univ Virginia Hlth Syst, Dept Orthopaed Surg, Charlottesville, VA 22908 USA
关键词
ROTATIONAL MALALIGNMENT; RADIATION-EXPOSURE; FEMORAL FRACTURES; FLUOROSCOPY; FIXATION; GUIDANCE; FEMUR;
D O I
10.2106/JBJS.H.01286
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The first computer-assisted orthopaedic trauma procedures were limited to navigated drill-guide applications, in which the computer was used to predict the trajectory of the drill guide relative to stored radiographic images. By 2003, software for fracture reduction was commercially available. The ability to perform a minimally invasive fracture reduction with the aid of stored images, combined with navigated insertion of internal fixation, has long been considered the highest achievement in image-guided fracture surgery. It is now possible to apply computer-assisted techniques to all fractures that have traditionally been treated with the aid of intraoperative fluoroscopic control. Less-invasive fixation of long-bone fractures is often complicated by malrotation or shortening of the injured extremity, sometimes requiring reoperation. Recent developments in computer-assisted surgery now allow the orthopaedic surgeon to precisely match the anatomy of the injured extremity to that of the uninjured limb with respect to length and rotational alignment. This is particularly important in comminuted fractures, for which there are no anatomic clues to guide accurate reduction, and in the correction of malreduced fractures. Although computer-assisted technology is now readily available, it has not yet found widespread acceptance in the orthopaedic trauma community. New software workflows (i.e., the step-by-step progression through various screens in the software program during a computer-guided procedure) specific to individual procedures and implants may hasten adoption of these techniques.
引用
收藏
页码:102 / 107
页数:6
相关论文
共 15 条
  • [1] Evidence-based approaches to minimizing malpractice risk in orthopedic surgery
    Bhattacharyya, T
    [J]. ORTHOPEDICS, 2005, 28 (04) : 378 - 381
  • [2] CHAO EYS, 1998, NIH AAOS RES S NEW E
  • [3] PERCUTANEOUS SCREW FIXATION OF ACETABULAR FRACTURES WITH CT GUIDANCE - PRELIMINARY-RESULTS OF A NEW TECHNIQUE
    GAY, SB
    SISTROM, C
    WANG, GJ
    KAHLER, DA
    BOMAN, T
    MCHUGH, N
    GOITZ, HT
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 158 (04) : 819 - 822
  • [4] The effects of femora shaft malrotation on lower extremity anatomy
    Gugenheim, JJ
    Probe, RA
    Brinker, MR
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2004, 18 (10) : 658 - 664
  • [5] Compensation for rotational malalignment after intramedullary nailing for femoral shaft fractures an analysis by plantar pressure measurements during gait
    Jaarsma, RL
    Ongkiehong, BF
    Grüneberg, C
    Verdonschot, N
    Duysens, J
    van Kampen, A
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2004, 35 (12): : 1270 - 1278
  • [6] Rotational malalignment after fractures of the femur
    Jaarsma, RL
    van Kampen, A
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (08): : 1100 - 1104
  • [7] Rotational malalignment after intramedullary nailing of femoral fractures
    Jaarsma, RL
    Pakvis, DFM
    Verdonschot, N
    Biert, J
    van Kampen, A
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2004, 18 (07) : 403 - 409
  • [8] Image guidance - Fluoroscopic navigation
    Kahler, DM
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (421) : 70 - 76
  • [9] Kahler DM, 2001, ST HEAL T, V81, P225
  • [10] Kahler DM., 2003, TECH ORTHOP, V18, P174